Maintenance Codes
Error Code: Description:
| 0001 | The counter of waste ink used for printing margins at borderless printing has reached the specified value. |
|
| 0002 | The CR scan pass counter has reached the specified value. (ink supply tube has reached its end of life.) |
|
| 0008 | The RTC backup battery becomes exhausted. | |
| 0040 | The pump counter has reached the specified value. | |
| 0080 | The date has not been set. | |
| 0100 | The RTC backup battery power has temporarily dropped. | |
| 0800 | The ink cartridge installation/removal counter has reached the upper limit. |
|
| 1000 | The number of drives of the ink selector has reached the upper limit. |
|
| 0088 | RTC backup battery has not been set. |
Service Call Errors
Error Code: Description:
| 1101 | CR life error | |
| 1120 | CR lock error | |
| 1121 | CR reverse error | |
| 1122 | CR overspeed error | |
| 1123 | Duty over error | |
| 1124 | Drive timeover error | |
| 1125 | CR home position detection error | |
| 1126 | CR lock release error | |
| 1127 | CR lock set error | |
| 1130 | Overspeed error (PID-load positioning) | |
| 1131 | Drive timeover error (PID-load positioning) | |
| 1132 | Out of sync. (PID-load positioning) | |
| 1133 | Positioning time-out (PID-load positioning) | |
| 1134 | Integral term overload (PID-load positioning) | |
| 1135 | Encoder test error (PID-load positioning) | |
| 1220 | Overspeed error | |
| 1221 | PF measurement error | |
| 1222 | Drive timeover error | |
| 1223 | Encoder test error | |
| 1224 | Out of sync | |
| 1225 | Positioning time-out | |
| 1226 | Integral term overload | |
| 131B | Head driver (transmission gate) temp. error | |
| 1400 | Pressure motor drive timeover | |
| 1401 | Air leaks | |
| 1403 | Pressure reducing error | |
| 1404 | Pump movement cycle over error | |
| 1410 | Drive time monitor time-out (PUMP) | |
| 142D | Pump cap unit life error | |
| 1425 | CSIC communication time-out | |
| 1430 | Holder ink pad error |