Problem: Possible Cause:
System Error #1 ( Drive Motor Error) |
The Motor connector is not properly connected. The Motor has failed. Controller failure. |
|
System Error #2 (INDEX Error) |
Spinner Motor may not be functioning. Controller failure. |
|
System Error #3 (No active video) |
J1 shunt is not installed on AP27354. The AP140004 Board is defective. |
|
System Error #4 (Fatal Cutter Error) |
The Cutter may have stopped. May have a faulty Cutter Parked Sensor. Set screw on the Cutter Motor pulley may have loosened. |
|
System Error #5 (Lazy Loop failed) |
Lazy Loop Motor failed. Controller failure |
|
System Error #6 (Head Punch Error) |
Loose cable. Head Punch Motor failed. Controller failure. Parked Sensor faulty or misadjusted. |
|
System Error #7 (Tail Punch error) |
Loose cable. Tail Punch Motor failed. Controller failure. Parked Sensor faulty or misadjusted. |
|
System Error #8 (Pinch Not Parked error) |
Loose cabling. Bad Pinch Motor. Incorrect Sensor adjustment. Defective sensor. |
|
System Error #9 (Spinner confidence test failure) |
Loose cable. Insufficient voltage / current Spinner Controller board fails to maintain speed. Bad Spinner |