Maintenance Codes
Error Code: Description:
0002 | The number of CR movement cycles has reached predetermined value | |
0008 | RTC backup battery shut off / uninstalled | |
0040 | Pump counter has reached predetermined amount | |
0080 | Date is not set | |
0088 | RTC backup battery is not installed | |
0100 | RTC backup battery pressure is temporally low | |
0200 | The number of ASF paper feeding has reached predetermined value |
Service Call Errors
Error Code: Description:
00000101 | The CR motor life | |
00001A40 | Communication error between the main board and sub board | |
00010000 | PF motor encoder check error | |
00010001 | PF motor out of step | |
00010002 | PF Motor over current | |
00010003 | PF Motor in-position time-out | |
00010004 | CR Motor Encoder check error | |
00010005 | CR motor out of step | |
00010006 | CR Motor over current | |
00010007 | CR Motor in-position time-out | |
00010008 | Servo interrupt watchdog time-out | |
00010009 | System interrupt watchdog time-out | |
0001000A | CR axis detection error | |
0001000C | PG axis detection error | |
0001000F | CR Motor PWM output faulty | |
00010010 | PF Motor PWM output faulty | |
00010012 | CR overload (high sensitivity) error | |
00010013 | PR overload (high sensitivity) error | |
0001001B | Head driver (TG) temperature error | |
0001001D | CR servo parameter error | |
0001001E | PF servo parameter error | |
00010020 | CSIC reading / writing error | |
00010020 | Ink type error (setting on printer body side) | |
00010022 | Ink type error (setting on printer body side) | |
00010023 | RTC analysis error | |
00010025 | CSIC ROM communication error | |
00010026 | RTC communication error | |
00010028 | Head error | |
00010029 | Unidentified NMI | |
0001002A | CR ASIC ECU error | |
0001002B | PF ASIC ECU error | |
0001002D | The Cleaning Unit reached its end of life | |
0001002F | 360 DPI writing time out error | |
00010030 | Multi Sensor failure | |
00010031 | ASF phase detection error | |
00010032 | ASF drive switch error | |
00010033 | Eject phase detection error | |
00010034 | Eject movement error | |
00010035 | Pump phase detection error | |
00010036 | Type-B board installation error | |
00010037 | Head thermistor error | |
00010038 | Transistor thermistor error | |
00010039 | PG adjustment value incorrect overwrite error | |
0001003A | PG adjustment value outside range error | |
0001003B | Cutter installation error 1 | |
0001003C | Cutter installation error 2 | |
0001003D | Cutter installation error 3 | |
00020000 | NVRAM error | |
00020002 | SDRAM error | |
00020003 | BOOT program SUM error | |
00020009 | Flash memory SUM error | |
0002000A | Program load error | |
0002000B | The internal memory is insufficient | |
0003xxxx | Debug error code | |
0Dxxxxxx | Debug error code | |
0Exxxxxx | RTC timer off error | |
100000E0 | CPU address error (load misalignment) | |
10000100 | CPU address error (storage misalignment) | |
10000180 | CPU reserve command code exception error | |
100001A0 | CPU slot illegal command exception error | |
100001C0 | AC disruption | |
100005C0 | CPU DMA address error | |
10000xxx | CPU error |