Error Index:
0000-9FFF: Errors | 0000-00FF: reserve | |
0100-08FF: boot system | ||
0800-0FFF: main control | ||
1000-1FFF: communication control | ||
2000-2FFF: video control | ||
3000-3FFF: Material control | ||
4000-4FFF: feed control | ||
5000-5FFF: user interface | ||
6000-6FFF: machine drivers | ||
7000-77FF: operating system PSOS-Fehler | ||
7800-7BFF: file system | ||
7C00-7DFF: laser control HELIOS | ||
7E00-7FFF: peeler control HELIOS | ||
8000-87FF: ecc control | ||
8800-9FFF: reserve (free) | ||
A000-BFFF: Warnings | A000-A1FF: boot system | |
A200-A3FF: main control | ||
A400-A5FF: communication control | ||
A600-A7FF: video control | ||
A800-A9FF: Material control | ||
AA00-ABFF: feed control | ||
AC00-ADFF: user interface | ||
AE00-AFFF: machine driver | ||
B000-B1FF: operation system PSOS+ | ||
B200-B3FF: file system | ||
B400-B5FF: ecc control | ||
B600-BFFF: reserve (free) | ||
C000-DFFF: User Info | C000-C3FF: user intervention for STA | |
C400-C7FF: user intervention for ORL | ||
C800-CBFF: user intervention for SWE | ||
CC00-CFFF: user intervention for HAU | ||
C400-C7FF: user intervention for ORL | ||
D400-DFFF: reserve (free) | ||
E000-FFFE: reserve | ||
FFFF: special used | FFFF : special used by HERKULES |
Error: Description:
USER INFO 0000 | Recorder is ready for operating | |
ERROR 0001 | Recorder in test run – No exposure possible | |
ERROR 0800 | Recorder hardware defective | |
ERROR 0801 | The inserted diskette is not the system diskette for this recorder | |
ERROR 0802 | The graphics display could not be initialized | |
ERROR 0803 | The material reception unit (collecting cassette or on-line device connected) has not been selected | |
ERROR 0804 | Supply cassette not inserted | |
ERROR 0805 | Collecting cassette not inserted | |
ERROR 0806 | Material feed error | |
ERROR 0807 | Collecting cassette has not been emptied | |
ERROR 0808 | Material feed into the material reception unit (collecting cassette or connected on-line device) not possible | |
ERROR 0809 | An error occurred in the recorder cutting device | |
ERROR 080A | Supply cassette is empty | |
ERROR 080D | Internal error | |
ERROR 080E | An error occurred during the automatic material position and width recognition | |
ERROR 080F | The on-line processor is not switched on | |
ERROR 0810 | On-line processor not ready | |
ERROR 0811 | The on-line processor is not connected to the on-line recorder interface | |
ERROR 0812 | Power supply error – An error occurred in the negative 12 Volt power supply; | |
ERROR 0813 | Power supply error – An error occurred in the positive 12 Volt power supply | |
ERROR 0814 | Power supply error – An error occurred in the negative 15 Volt power supply | |
ERROR 0815 | Power supply error – An error occurred in the positive 15 Volt power supply | |
ERROR 0816 | Power supply error – An error occurred in the first negative 2 Volt power supply | |
ERROR 0817 | Power supply error – An error occurred in the negative 5.2 Volt power supply | |
ERROR 0818 | Power supply error – An error occurred in the positive 7.5 Volt power supply | |
ERROR 0819 | Power supply error – An error occurred in the positive 24 Volt power supply | |
ERROR 081A | Power supply error – An error occurred in the second negative 2 Volt power supply | |
ERROR 081B | Power supply error – An error occurred in the positive 28 Volt power supply | |
ERROR 081C | Power supply error – An error occurred in one of the power supply modules | |
ERROR 081D | The recorder could not be initialized | |
ERROR 081F | The supply cassette does not belong to this recorder | |
ERROR 0900 | The communication with the laser unit is interrupted | |
ERROR 1001 | No more memory available to create a SPEEDWAY message | |
ERROR 2000 | The recorder hardware could not be reset | |
ERROR 2001 | The recorder hardware could not be initialized | |
ERROR 2002 | The recorder hardware could not be reset | |
ERROR 2003 | The recorder hardware could not be initialized | |
ERROR 2004 | The recorder hardware could not be initialized | |
ERROR 2005 | The recorder hardware could not be initialized | |
ERROR 2007 | The recorder hardware could not be initialized | |
ERROR 2008 | The SPEEDWAY link is interrupted | |
ERROR 2009 | The SPEEDWAY link is interrupted | |
ERROR 200A | The SPEEDWAY link is interrupted | |
ERROR 200B | The system memory for SPEEDWAY communication could not be released | |
ERROR 200C | An error occurred in the program sequence | |
ERROR 3101 | An internal error occurred when calling up the material control | |
ERROR 3102 | An internal error occurred when calling up the material control | |
ERROR 3103 | An internal error occurred when calling up the material control | |
ERROR 3104 | An internal error occurred when calling up the material control | |
ERROR 3105 | An internal error occurred when calling up the material control | |
ERROR 3106 | The material feed length exceeds the maximum feed length | |
ERROR 3107 | The material type, which is selected in the material parameter MATERIAL_TYPE, isn’t supported by the recorder | |
ERROR 3108 | The material thickness (in combination with the selected material type) isn’t supported by the recorder. The thickness is selected in the material parameter MATERIAL_THICKNESS | |
ERROR 3109 | The measured material width (in combination with the selected material thickness and material type) isn’t supported by the recorder | |
ERROR 3110 | The VAR_MAT_CONTROL-parameters (PID 681-700) in the static parameters do not have the defined format or they are corrupted | |
ERROR 3200 | An error occurred when initializing the punch | |
ERROR 3201 | An error occurred when selecting the punches | |
ERROR 3202 | An error occurred during the punching | |
ERROR 3300 | An error occurred during the transport of the residual material – The supply cassette is empty | |
ERROR 3301 | An error occurred during the transport of the residual material – The supply cassette is empty | |
ERROR 3302 | An error occurred during the transport of the residual material – The supply cassette is empty | |
ERROR 3400 | The residual material measurement is incorrect | |
ERROR 3401 | The residual material measurement is incorrect | |
ERROR 3402 | The residual material measurement is incorrect | |
ERROR 3500 | An error occurred during the material transport | |
ERROR 3501 | An error occurred when loading the material | |
ERROR 3502 | An error occurred during the material transport | |
ERROR 3503 | An error occurred during the material transport | |
ERROR 3504 | An error occurred during the material transport | |
ERROR 3505 | An error occurred during the material transport | |
ERROR 3506 | An error occurred during the material transport | |
ERROR 3507 | An error occurred when loading the material | |
ERROR 3508 | An error occurred when loading the material. The end of material has been recognized | |
ERROR 3509 | An error occurred when loading the material. The end of material has been recognized | |
ERROR 350A | An error occurred during the loading process. Material jam has occurred | |
ERROR 350B | An error occurred during the loading process. Material jam has occurred | |
ERROR 350C | An error occurred during the loading process. There is residual material in the recorder trough. The end of material has been recognized | |
ERROR 350D | An error occurred during the unloading process | |
ERROR 350F | An error occurred during the unloading process | |
ERROR 3510 | An error occurred during the unloading process | |
ERROR 3511 | An error occurred during the unloading process | |
ERROR 3512 | An error occurred during the unloading process | |
ERROR 3515 | An error was detected during material feed. Material jam occured | |
ERROR 3516 | An error was detected during material feed. Material jam in the output unit of the recorder has occured | |
ERROR 3600 | An internal error occurred when transferring the parameters | |
ERROR 3601 | An internal error occurred when transferring the parameters | |
ERROR 3602 | An internal error occurred when transferring the parameters | |
ERROR 3700 | A problem occurred in the material guide system | |
ERROR 3701 | A problem occurred in the material guide system | |
ERROR 3702 | A problem occurred in the material guide system | |
ERROR 3703 | A problem occurred in the material guide system | |
ERROR 3704 | A problem occurred in the material guide system | |
ERROR 3705 | A problem occurred in the material guide system | |
ERROR 3706 | A problem occurred in the material guide system | |
ERROR 4000 | Parameter set-up error | |
ERROR 4001 | An error occurred during the initialization of the recorder hardware | |
ERROR 4002 | SlowScan feed error | |
ERROR 4003 | SlowScan feed error | |
ERROR 4004 | An error occurred in the SlowScan feed unit | |
ERROR 4005 | The dust cover and (or) the side panel are not closed | |
ERROR 4006 | The dust cover and (or) the side panel are not closed | |
ERROR 4007 | Material jam in the recorder | |
ERROR 4008 | An error occurred during the material width measurement | |
ERROR 6000 | An error occurred when accessing the non-volatile memory of the supply cassette | |
ERROR 6001 | An error occurred when accessing the non-volatile memory of the supply cassette | |
ERROR 6002 | An internal error occurred when accessing the non-volatile memory of the supply cassette | |
ERROR 6003 | A non-volatile memory is missing in the recorder | |
ERROR 6004 | The supply cassette has not been inserted | |
ERROR 6005 | An internal error occurred when accessing the non-volatile memories | |
ERROR 6006 | An internal error occurred when accessing the non-volatile memories | |
ERROR 6007 | An error occurred when accessing the non-volatile memories | |
ERROR 6008 | An error occurred when accessing the non-volatile memories | |
ERROR 6009 | An internal error occurred when accessing the non-volatile memories | |
ERROR 7000 | Internal operating system error | |
ERROR 7001 | Internal operating system error | |
ERROR 7002 | Internal operating system error | |
ERROR 7003 | Internal operating system error | |
ERROR 7004 | Internal operating system error | |
ERROR 7005 | Internal operating system error | |
ERROR 7006 | Internal operating system error | |
ERROR 7800 | No diskette or the wrong diskette has been inserted | |
ERROR 7801 | Diskette error: File cannot be opened | |
ERROR 7802 | Diskette error: File cannot be found | |
ERROR 7803 | Diskette error: File cannot be read | |
ERROR 7804 | Diskette error: File cannot be written | |
ERROR 7805 | Diskette error: File cannot be created | |
ERROR 7806 | Diskette error: File cannot be deleted | |
ERROR 7807 | Diskette error: File cannot be renamed | |
ERROR 7808 | Diskette error: Directory cannot be changed | |
ERROR 7809 | Diskette error: Directory cannot be created | |
ERROR 780A | Diskette error: Diskette is write-protected | |
ERROR 780B | The inserted diskette is no UPDATE diskette | |
ERROR 780C | The inserted diskette is no recorder system diskette | |
ERROR 7C3D | EEPROM Data read error has occured | |
ERROR 7C3E | AC-fault greater than 50 milliseconds | |
ERROR 7C40 | A transmission error on LASERWAY has occured | |
ERROR 7C41 | The laser power is outside the ready range | |
ERROR 7C42 | Laser power mode – an adjust timeout has occured | |
ERROR 7C43 | Laser power supply – an over-temperature error on the passbank has occured | |
ERROR 7C44 | Laser module – the current limit is reached | |
ERROR 7C45 | Diode module safety loop test – a bad voltage was detected | |
ERROR 7C46 | Diode module safety loop check – a logic-fault was detected | |
ERROR 7C47 | Diode module safety check 2 – a bad voltage was detected | |
ERROR 7C48 | Diode module safety check 2 – a logic-fault was detected | |
ERROR 7C49 | Diode module safety check 1 – a bad voltage was detected | |
ERROR 7C4A | Diode module safety check 1 – a logic-fault was detected | |
ERROR 7C51 | Diode module – the EEPROM data is not available | |
ERROR 7C52 | Diode module – a EEPROM data write failure has occured | |
ERROR 7C53 | Laser module – a bad microprocessor configuration was detected | |
ERROR 7C54 | Laser module – a failure of the cooling system was detected | |
ERROR 7C55 | Laser module – a failure of the heater system was detected | |
ERROR 7C58 | Diode module – the thermistor is shorted | |
ERROR 7C59 | Diode module – the thermistor is open | |
ERROR 7C5B | Diode module – an over-temperature error has occured ( > 37.5 C) | |
ERROR 7C5C | Diode module – an under-temperature error has occured ( < 7.5 C) | |
ERROR 7C5D | Laser module – the current limit PASSBANK is reached (2) | |
ERROR 7C5E | Laser module – the current limit PASSBANK is reached (1) | |
ERROR 7C5F | The laser module safety loop is open | |
ERROR 7C62 | The diode module relay is closed but should be open | |
ERROR 7C63 | The diode module relay is open but should be closed | |
ERROR 8000 | Internal error | |
ERROR 8001 | Internal error | |
ERROR 8002 | An error occurred in the recorder hardware | |
ERROR 8003 | An error occurred in the recorder hardware | |
ERROR 8004 | An error occurred in the recorder hardware | |
ERROR 8005 | An error occurred in the recorder hardware | |
ERROR 8100 | A parameter set-up error occurred in the optics unit | |
ERROR 8101 | A parameter set-up error occurred in the optics unit | |
ERROR 8102 | A parameter set-up error occurred in the optics unit | |
ERROR 8110 | An error occurred in the optics unit of the recorder | |
ERROR 8111 | An error occurred in the optics unit of the recorder | |
ERROR 8112 | An error occurred in the optics unit of the recorder | |
ERROR 8120 | An error occurred in the optics unit of the recorder | |
ERROR 8121 | A parameter set-up error occurred in the optics unit | |
ERROR 8122 | A parameter set-up error occurred in the optics unit | |
ERROR 8200 | An error occurred in the mirror motor unit | |
ERROR 8201 | A parameter set-up error of the mirror motor unit occurred | |
ERROR 8202 | An error occurred in the mirror motor unit | |
ERROR 8203 | An error occurred in the mirror motor unit | |
ERROR 8204 | An error occurred in the mirror motor unit | |
ERROR 8205 | An error occurred in the mirror motor unit | |
ERROR 8300 | The voltage monitoring recognized an error | |
ERROR 8301 | The voltage monitoring recognized an error | |
ERROR 8302 | The voltage monitoring recognized an error | |
ERROR 8303 | The temperature monitoring of the optics unit recognized an error | |
ERROR 8304 | The temperature monitoring of the optics unit recognized an error | |
ERROR 8310 | An internal error occurred | |
ERROR 83F1 | An error occurred when preparing the optics for exposure | |
WARNING A600 | The recorder is in test operation mode | |
WARNING AC00 | The selected material is not in the supply cassette | |
USER INFO CC00 | The image data have not been all processed during the exposure | |
USER INFO CC01 | The *.RIF initialization file cannot be read from the diskette | |
USER INFO CC02 | The recorder hardware and software are incompatible | |
USER INFO CC03 | The recorder received an unacceptable application parameter from the RIP | |
USER INFO CC04 | The recorder received an unacceptable application parameter from the RIP | |
USER INFO CC05 | The recorder received an unacceptable application parameter from the RIP | |
USER INFO CC06 | The recorder received an unacceptable application parameter from the RIP | |
USER INFO CC07 | The recorder received an unacceptable application parameter from the RIP | |
USER INFO CC08 | The recorder received an unacceptable application parameter from the RIP | |
USER INFO CC09 | The recorder received an unacceptable application parameter from the RIP | |
USER INFO D000 | There is no diskette in the drive | |
USER INFO D001 | The diskette in the drive is defective or has a wrong format, e.g. DD(720KB) |