Error: Description: More Details:
0 | Recorder is ready for operating | |||
1 | Internal Error | An error occurred in the program sequence | ||
2 | Internal Error | An error occurred in the program sequence | ||
12 | Internal Error | Internal communication error | ||
35 | An error occurred in a database. | The specified record is not available. | ||
36 | An error occurred in a database. | The specified error got a different type. | ||
37 | An error occurred in a database. | The length of the value of the specified error is to long for the delivered buffer | ||
38 | An error occurred in a database. | The length of the buffer of the specified record is to short for the delivered value | ||
40 | An error occurred in a database | The insertion of a record into a database is not possible | ||
41 | An error occurred in the file system | A file could not be opened | ||
42 | An error occurred in the file system | A file could not be closed | ||
43 | An error occurred in the file system | A file could not be seeked | ||
44 | An error occurred in the file system | A file could not be written | ||
45 | An error occurred in the file system | A file could not be read | ||
48 | An error occurred while allocating memory | Memory could not be allocated | ||
49 | An error occurred while parsing a source | A syntax error is occurred | ||
94 | Internal system error | Error using operating system function | ||
95 | Internal system error | Error using operating system function | ||
96 | Internal system error | Error using operating system function | ||
97 | Internal system error | Error using operating system function | ||
98 | Internal system error | Error using operating system function | ||
99 | Internal system error | Error in file operation | ||
100 | Internal system error | Error in file operation | ||
101 | Internal system error | Error in file operation | ||
102 | Internal system error | Error in file operation | ||
103 | Internal system error | Error in file operation | ||
104 | Internal system error | Error in file operation | ||
105 | Internal system error | Error in file operation | ||
106 | Internal system error | Error in file operation | ||
107 | Internal system error | Error in file operation | ||
108 | Internal system error | Error in file operation | ||
109 | Internal system error | Error in file operation | ||
110 | Internal system error | Error in file operation | ||
111 | Internal system error | Error in file operation | ||
112 | Internal system error | Error using operating system function | ||
113 | Internal system error | Error using operating system function | ||
114 | Internal system error | Error using operating system function | ||
115 | Internal system error | Error using operating system function | ||
116 | Internal system error | Error using operating system function | ||
117 | Internal system error | Error using operating system function | ||
118 | Internal system error | Error using operating system function | ||
119 | Internal system error | Error using operating system function | ||
120 | Internal system error | Error using operating system function | ||
121 | Internal system error | Error using operating system function | ||
122 | Internal system error | Error using operating system function | ||
123 | Internal system error | Error using operating system function | ||
124 | Internal system error | Error using operating system function | ||
126 | Internal system error | Error in file operation | ||
128 | Internal system error | Error in file operation | ||
129 | Internal system error | Error in filebox | ||
130 | Internal system error | Error in filebox | ||
133 | Communication error | Speedway communication error | ||
134 | Communication error | Speedway communication error | ||
135 | Internal system error | Error using operating system function | ||
136 | Internal system error | Error using operating system function | ||
146 | Internal system error | Internal communication error | ||
147 | Internal system error | Internal communication error | ||
148 | Internal system error | Internal communication error | ||
149 | Internal system error | Internal communication error | ||
150 | Internal system error | Internal communication error | ||
151 | Internal system error | Internal communication error | ||
152 | Internal system error | Internal communication error | ||
153 | Internal system error | Internal communication error | ||
154 | Internal system error | Internal communication error | ||
155 | Internal system error | Error using operating system function | ||
156 | Internal system error | Error using operating system function | ||
157 | Internal system error | Error using operating system function | ||
158 | An error occurred in a database | The erasing of a record out of a database is not possible | ||
163 | Internal system error | Error in file operation | ||
164 | Internal system error | Error in file operation | ||
170 | An internal hardware error occurred | FPGA busy error | ||
171 | An internal hardware error occurred | FPGA detection error | ||
172 | An internal hardware error occurred | FPGA initialization error | ||
173 | An internal hardware error occurred | FPGA busy error | ||
174 | An internal hardware error occurred | FPGA frame data error during configuration | ||
175 | An internal hardware error occurred | FPGA length count error | ||
220 | An error occurred in a database | A file which should be copied does not exist | ||
221 | An error occurred in a database | A file could not be deleted | ||
222 | An error occurred in a database | A file could not be copied | ||
223 | An error occurred in a database | A directory could not be created | ||
224 | An error occurred while parsing a source | A serious syntax error is occurred | ||
225 | An error occurred while parsing a source | A serious syntax error is occurred | ||
234 | Internal error | Operating system error | ||
235 | Internal error | Operating system error | ||
237 | An internal hardware error occurred | Communication error on the SPI Bus | ||
282 | Internal system error | Error in Package | ||
283 | Internal system error | Error in Package | ||
284 | Internal system error | Error in FPGA box | ||
285 | Internal system error | Error in FPGA box | ||
293 | The current machine type is usable for test purposes only | The current machine type is usable for test purposes only | ||
294 | The current machine type is invalid | The current machine type is invalid | ||
295 | The current machine variation is invalid | The current machine variation is invalid | ||
313 | Internal system error | Operating system error | ||
314 | Internal error | Operating system error | ||
319 | An error occurred while parsing a source | A semantics error occurred | ||
320 | An error occurred while parsing a source | Simple semantics error | ||
321 | An error occurred while parsing a source | Serious semantics error | ||
322 | Switch off sequence initiated | Fast switch off sequence initiated | ||
323 | Fast switch off sequence initiated | A second switch off command was received. Only data will be saved before switch | ||
324 | An error occurred in the parameter database | The parameter configuration file does not exist | ||
400 | Internal error | Undefined error | ||
401 | Internal error | Undefined error | ||
402 | Internal error | Wrong magic number received with the data | ||
403 | Internal error | Buffer size error | ||
404 | Internal error | Checksum error | ||
405 | Internal error | Error after select() function | ||
406 | Internal error | select() timeout | ||
407 | Internal error | Error after ioctl() function | ||
408 | Internal error | Not enough buffer for download | ||
409 | Internal error | Not enough buffer for download | ||
410 | Internal error | Not enough FLASH memory | ||
411 | Internal error | Unknown FLASH vendor | ||
412 | Internal error | Unknown FLASH module | ||
413 | Internal error | Invalid FLASH map | ||
414 | Internal error | FLASH not ready | ||
415 | Internal error | Error clearing the FLASH | ||
416 | Internal error | Error clearing the FLASH | ||
417 | Internal error | Error clearing the FLASH | ||
418 | Internal error | Error clearing a FLASH sector | ||
419 | Internal error | Error clearing a FLASH sector | ||
420 | Internal error | Error checking a FLASH sector | ||
421 | Internal error | Timeout programming the FLASH | ||
422 | Internal error | FLASH not ready | ||
423 | Internal error | Error comparing the FLASH after write operation | ||
424 | Internal error | Error connecting with an interrupt | ||
425 | Internal error | Error activating an interrupt | ||
426 | Internal error | Out of init error memory | ||
427 | Internal error | Error initializing the hardware | ||
428 | Internal error | Error reading from FLASH | ||
429 | Internal error | Error writing to FLASH | ||
430 | Internal error | Error after open() function | ||
431 | Internal error | Error after close() function | ||
440 | Internal system error | Error using operating system function | ||
441 | Internal system error | Error using operating system function | ||
442 | Internal system error | Error using operating system function | ||
443 | Internal system error | Error using operating system function | ||
3001 | The ventilator for the central electronics is defective! Forcing power off of the recorder | Electronics ventilator monitor reports an error. You cannot continue operation. Powering down the recorder | ||
3002 | Wrong Bacher punch configuration | Bacher Configuration parameter (PID 21958) is wrong. The bit map of the Bacher Configuration (PID 21958) must be a subset of the bit map of the Punch Configuration (PID 766) | ||
3003 | The ventilator of the air filter is not working. There will be a loss of recorder quality due to dirty mirrors if this error occurs over a longer period of time | The ventilator of the air filter is not rotating or the phase sequence sensor is defective | ||
3004 | The air filter is used and must be replaced. There will be a loss of recorder quality due to dirty mirrors if this error occurs over a longer period of time | The sensor for the air filter reports that the filter is used | ||
3005 | Max. output level of the optical head is not enough to image in the selected mode | Max. output level of the optical head is not enough to image in the selected mode | ||
3006 | Max. output level of the optical head is not enough to image in the selected mode | Cannot end an action in the recorder because of a preceding error or power-off function | ||
3007 | Punch setting doesn’t match punch configuration | RIP punch action doesn’t match punch configuration | ||
3008 | ATTENTION: Plate lost in device! Do NOT correct error | A plate was probably lost in the device during initialization. Error correction is illegal in this present state | ||
3009 | Internal communication error | Communication with an internal assembly (e.g. Optic) failed | ||
3010 | Internal communication error | Communication with with the Autoloader failed | ||
3011 | Error in the slow scan unit | Could not find resolution for calculation of an imaging ramp | ||
3012 | Network addresses (IP addresses) conflict | The two network addresses of the recorder must not come from the same network | ||
3014 | An error occurred in the mirror motor unit | The time monitor reports timeout during the spin-up phase of the mirror motor | ||
3015 | An error occurred in the mirror motor unit | The time monitor reports timeout during the spin-down phase of the mirror motor | ||
3016 | An error occurred in the air supply unit | The air safety switch is not closed | ||
3017 | An error occurred in the air supply unit | The mirror air cooler temperature is to high | ||
3018 | An error occurred in the air supply unit | Communication error on the I2C-Bus | ||
3019 | Internal communication error | The air pump did not start | ||
3020 | An error occurred in the air supply unit | The focus stepping motor cannot find the zero position | ||
3021 | An error occurred in the optic unit | The focus stepping motor cannot find the zero position | ||
3022 | A parameter set-up error occurred in the optic unit | The focus position set point is not within the permissible range | ||
3023 | An error occurred in the optic unit | The filter stepping motor cannot find the zero position | ||
3024 | An error occurred in the optic unit | The filter stepping motor cannot leave the zero position | ||
3025 | A parameter set-up error occurred in the optic unit | The filter number is not within the permissible range | ||
3026 | A parameter set-up error occurred in the optic unit | The number of the shaping element is not within the permissible range | ||
3027 | An error occurred in the optic unit | The adjust bias current of the laser diode is higher than the maximum current | ||
3028 | An error occurred in the optic unit | The maximum bias current of the laser diode is not sufficient to achieve the required light value | ||
3029 | An error occurred in the optic unit | The adjusted current of the laser diode is higher than the maximum current | ||
3030 | A parameter set-up error occurred in the optic unit | The modulation current of the laser diode set to maximum is not sufficient to achieve the required light value | ||
3031 | An error occurred in the optic unit | The laser diode must be on for the light stabilization | ||
3032 | An error occurred in the optic unit | The light stabilization must be off | ||
3033 | An error occurred in the optic unit | Passed value is to high for this function | ||
3034 | An error occurred in the optic unit | Passed value is to low for this function | ||
3050 | On board device error | Unable to set mirror power supply (36 V) | ||
3051 | An error occurred in the slow scan unit | The stepper board signals a short circuit, the safety loop is open or power supply (36V) failed | ||
3052 | An error occurred in the slow scan unit | The stepper board signals high temperature | ||
3053 | An error occurred in the slow scan unit | The stepper board signals not ready | ||
3054 | An error occurred in the slow scan unit | The carrier reaches the left limit | ||
3055 | An error occurred in the slow scan unit | The carrier reaches the right limit | ||
3056 | An error occurred in the slow scan unit | The carrier is moving when it is not allowed | ||
3057 | An error occurred in the slow scan unit | The safety loop is not closed | ||
3058 | An error occurred in the slow scan unit | An interrupt has occurred when not expected. Interrupt: Stop | ||
3059 | An error occurred in the slow scan unit | An interrupt has occurred when not expected. Interrupt: Signal of light barrier has changed | ||
3060 | An error occurred in the slow scan unit | An interrupt has occurred when not expected. Interrupt: Destination reached | ||
3061 | An error occurred in the slow scan unit | A SlowScan timeout is occurred during finding a position or moving into the light barrier | ||
3062 | An error occurred in the slow scan unit | A valid ramp could not be found | ||
3063 | An error occurred in the slow scan unit | A ramp which fits into a specified distance could not be found | ||
3064 | A parameter error occurred | The value of a parameter is not valid | ||
3078 | An internal software error occurred | An attempt to read an uninitialized ADC device. | ||
3088 | An error occurred while material handling | Timeout at build vacuum | ||
3089 | An error occurred while material handling | Timeout at vacuum off | ||
3138 | An error occurred at punch init | Punch not connected or not configured | ||
3159 | An error occurred in the slow scan unit | The safety loop is not closed | ||
3160 | An error occurred in the slow scan unit | The carrier reaches the left limit | ||
3161 | An error occurred in the slow scan unit | The carrier reaches the right limit | ||
3162 | An error occurred in the slow scan unit | The stepper board signals not ready | ||
3165 | An error occurred while setting the light intensity | The BaseIntensity value for the selected resolution of the current job is lower than the adjustable light | ||
3168 | An error occurred in the slow scan unit | The feed ramp could not be written | ||
3169 | An error occurred in the slow scan unit | Error while calculating feed ramp data | ||
3198 | Not calibrated resolution selected | The selected resolution is not calibrated. The BaseIntensity parameter for the selected resolution is zero | ||
3199 | An communication error to the optic head occurred | The communication to the optic head is broken | ||
3200 | An communication error to the optic head occurred | The communication to the optic head is faulty | ||
3201 | An error occurred in the optichead unit | The number of gate impulses generated by the Image-Control is out of range | ||
3202 | An error occurred in the optichead unit | The temperature of the laser diode did not change after switching on the temperature regulation | ||
3203 | An error occurred in the optichead unit | The temperature of the laser diode is over the maximum allowed temperature | ||
3204 | An error occurred in the optichead unit | A parameter transmitted to the optichead is out of range | ||
3205 | An error occurred in the optichead unit | A parameter transmitted to the optichead is out of range | ||
3206 | An error occurred in the optichead unit | An error without a defined event has occurred | ||
3207 | An error occurred in the optichead unit | The light value on the laser diode with the bias current alone is higher than the value in the application data. This may be due to an error in the primesetter or a not initialized material data set or an defective optichead | ||
3208 | An error occurred in the optichead unit | The error occurs if you switch on the temperature regulation on the optichead without a regulation device | ||
3209 | An error occurred in the optichead unit | The mirror phased out during transmission. The mirror is not locked | ||
3211 | The mirror phased out during transmission. The mirror is not locked | The detect vacuum is much too low | ||
3212 | An error occurred while selecting the focus value | The RIP transmitted resolution is not a element of the recorder resolution table | ||
3213 | An error occurred while selecting the focus value | The calculation of the spotshape value failed | ||
3214 | An error occurred in the optic unit | The calculation of the filter value failed | ||
3215 | An error occurred in the optic unit | The calculation of the physical focus value failed | ||
3216 | An error occurred in the optic unit | The calculation of the physical focus value failed | ||
3217 | The safety loop was at least briefly interrupted | |||
3226 | An error occurred while setting the light intensity | The BaseIntensity value for the selected resolution of the current job is lower than the adjustable light | ||
3227 | An error occurred while setting the light intensity | The BaseIntensity value for the selected resolution of the current job is higher than the adjustable light | ||
3228 | An error occurred in the optichead unit | The light value on the laser diode with the modulation current alone is to high . This may be due to an error in the primesetter or an defective optichead | ||
3229 | An error occurred in the air supply unit | The high-water sensor is still active, after water blow-off | ||
3230 | An error occurred in the air supply unit | The high-water sensor is still active, after water blow-off | ||
3238 | Plate on table missing for load | Possibly plate detector (on plate table) defect | ||
3239 | An error occurred at punch action | Timeout at punch action (10s) at arrive ls | ||
3240 | An error occurred at material transport | Timeout at drive plate slider to Down-Wait Position (prepare to load) | ||
3241 | An error occurred at material transport | Timeout at drive plate slider to Down-Free position (unload plate) | ||
3242 | An error occurred at material transport | Timeout at drive plate slider to Up-Unload Position (unload plate or init) | ||
3243 | An error occurred at material transport | Timeout at center plate on table | ||
3244 | Plate on the table is not valid. Measured plate width is different to requested plate | Plate on the table is not valid. Measured plate width is different to requested plate | ||
3245 | Inserted plate is not valid. Measured plate length is different to requested plate | Inserted plate is not valid. Measured plate length is different to requested plate | ||
3246 | Unexpected plate on table detected. Exposed plate can not be ejected | Unexpected plate on table detected. Exposed plate can not be ejected | ||
3247 | An error occurred at material transport | A timeout is occurred during moving the lift into a position. No interrupt occurred | ||
3248 | There is no plate at the grip. Loading material isn’t possible | The plate sensor at the grip signals no-plate | ||
3249 | An internal hardware error occurred | The lift stepping motor cannot find it’s zero position | ||
3250 | An internal hardware error occurred. One or more fans at the back-wall don’t work | One or more of the guide fans at the back-wall don’t work | ||
3251 | An internal hardware error occurred. One or more fans at the back-wall don’t work | One or more of the guide fans at the back-wall don’t work | ||
3252 | An internal hardware error occurred. One or more fans at the back-wall don’t work | One or more of the guide fans at the back-wall don’t work | ||
3253 | An internal hardware error occurred. One or more fans at the back-wall don’t work | One or more of the guide fans at the back-wall don’t work | ||
3254 | The safety loop is open | The safety loop is open | ||
3255 | An internal hardware error occurred | An internal hardware error occurred | ||
3256 | An internal hardware error occurred | An internal hardware error occurred | ||
3258 | Plate position in lift is not valid for unloading | Inserted plate is not valid. Measured plate length is different to requested plate | ||
3259 | An error occurred at material transport | An error occurred at material transport | ||
3260 | An error occurred at material transport | Moving the flaps failed. They didn’t reach their in-or-out target position | ||
3261 | An error occurred at material transport | Moving the flaps failed. They didn’t reach their in-or-out target position | ||
3262 | An error occurred at material transport | Lift didn’t reach it’s set position. Maybe stopped by a sporadic interrupt | ||
3263 | An error occurred at material transport | Moving the lift isn’t possible because the flaps stays in the path | ||
3264 | An error occurred at material transport | Moving the lift isn’t possible because the grip unit is in horizontal position | ||
3265 | An error occurred at material transport | There are no valid parameter available | ||
3266 | An error occurred at material transport | Lift lost it’s position. Lower reference light-barrier shows a position error bigger than 1.2mm | ||
3267 | Material Length isn’t possible to load | It isn’t possible to move the lift into the calculated load position for this material length | ||
3269 | An error occurred at material transport | This operation isn’t possible at this time because the system wasn’t initialized correctly | ||
3270 | The set lift position is out of range | It isn’t possible to move the lift into the calculated load position for this material length | ||
3271 | An error occurred at material transport | There are no valid parameter available | ||
3272 | An error occurred at material transport | Initializing of the lift not possible – maybe the grip is still under the hooks in the indrum | ||
3274 | An error occurred in the lift and grip unit | The stepper board signals not ready | ||
3275 | An error occurred in the lift and grip unit | The lift ramp could not be written | ||
3276 | An error occurred in the lift and grip unit | Error while calculating lift ramp data | ||
3277 | An error occurred in the lift and grip unit | Moving the lift isn’t possible because the flaps stays in the path | ||
3278 | An error occurred in the lift and grip unit | FPGA and Parameter Grip Mode do not match | ||
3279 | part of the covering isn’t closed correctly or the emergency switch is activated | |||
3280 | Exposed plate is keeping in recorder | Exposed plate is keeping in recorder | ||
3281 | The service switch bypasses the safety loop | |||
3286 | Unexpected plate on table detected. Init recorder or error correction not possible | Unexpected plate on table detected. Init recorder or error correction not possible | ||
3287 | An error occurred in the lift and grip unit | The lift stepping motor cannot find it’s zero position | ||
3288 | An internal hardware error occurred. One or more fans at the plate-table don’t work | One or more of the guide fans at the plate-table don’t work | ||
3289 | An internal hardware error occurred. One or more fans at the plate-table don’t work | One or more of the guide fans at the plate-table don’t work | ||
3296 | Voltage failure | The negative analog 5 V failed | ||
3297 | Voltage failure | The negative analog 5 V failed | ||
3298 | Voltage failure | The negative analog 5 V failed | ||
3299 | Voltage failure | The positive 36 V failed | ||
3300 | Voltage failure | The positive 15 V failed | ||
3301 | Voltage failure | The positive 42 V failed | ||
3302 | Voltage failure | The positive 7.5 V failed | ||
3303 | Voltage failure | The positive 7.5 V failed | ||
3304 | Voltage failure | The positive analog 24 V failed | ||
3305 | Voltage failure | The positive 3.3 V failed | ||
3306 | Voltage failure | The positive 2.5 V failed | ||
3307 | The positive 2.5 V failed | Safety loop check failed. Check the Logfile for further information | ||
3309 | An error occurred in the material base | The requested material does not exist | ||
3310 | An error occurred at material transport | The plate center unit does not left the light barrier | ||
3311 | An error occurred at material transport | An unexpected motor stop from stepper counter at plate centering | ||
3312 | An error occurred in the air supply unit | The air pressure did not reach the required minimum | ||
3315 | The aging of the laser diode has accelerated | Too few exposure time has elapsed since the last automatic increase of the bias current setvalue. Nevertheless the bias current setvalue will be increased | ||
3316 | The end of lifetime of the laser diode is approaching | The nominal maximum limit of the total current of the laser diode has been reached | ||
3317 | An error occurred in the air supply unit | The mirror air pressure is above stop-limit | ||
3318 | An error occurred in the air supply unit | The mirror air pressure is above stop-limit | ||
3325 | An error occurred in the material base. The preferred shaft has not been specified | The preferred shaft is used in case a material shall be loaded which gets no link from any shaft | ||
3326 | An error occurred in the material base | The name of the material that is send with the command request material is invalid | ||
3327 | Remove Plate from table. Plate is exposed | Remove Plate from table | ||
3328 | Remove Plate from table. Plate is unexposed | Remove plate from manual tray | ||
3329 | OLP program change necessary | OLP program change necessary | ||
3913 | Autoloader error state detected | Autoloader error state detected | ||
3914 | Internal software or parameter error | Syntax error in debug configuration | ||
3915 | The Emergency Switch is activated | |||
3916 | The boot sequence failed. Please reboot the system | The boot sequence failed. Please reboot the system | ||
4001 | Internal software or parameter error | Syntax error in debug configuration | ||
4002 | Execution error – A general STOP occurred | A general BREAK occurred | ||
4003 | Internal error – sensor not recognized | A sensor in the device does not respond | ||
4004 | Internal error – setting a sensor failed | Writing to a sensor failed | ||
4005 | Internal error – actuator not recognized | An actuator in the device does not respond | ||
4006 | An actuator in the device does not respond | Writing to an actuator failed | ||
4007 | Error checking the Cassette/Waste safety loop | There is a problem with the safety loop of the Cassette / Waste section. Checking it failed | ||
4008 | Invalid Autoloader machine type set | |||
4009 | Any part of the covering isn’t closed correctly | |||
4010 | The safety loop was at least briefly interrupted | |||
4011 | The service switch bypasses the safety loop | |||
4012 | Internal system error | Error using operating system function | ||
4013 | Error checking the cover safety loop | There is a problem with the safety loop of the cover section. Checking it failed | ||
4014 | Runtime error | Internal software error | ||
4015 | The Emergency Switch is activated | |||
4016 | The boot sequence failed. Please reboot the system | The boot sequence failed. Please reboot the system | ||
4100 | Error separating a plate | |||
4101 | Error initializing the shutter | Unable to access the shutter init sensor | ||
4102 | Error initializing the shutter | Unable to quit the shutter init sensor | ||
4103 | Error moving the shutter | Unable to move the shutter into waste position | ||
4104 | Error moving the shutter | The shutter failed to get to the material transfer position | ||
4105 | Error polling a load table plate sensor | Load table plate sensor on the suction cart not found | ||
4106 | Error separating | Plate lost while separating or during transport to the entry of the load table plate. The plate did not arrive at the relevant sensor | ||
4107 | Error placing the plate on the load table plate | Plate lost during transport to the load table plate, the table plate sensor on the suction cart fails to detect the plate at the end of the transfer process | ||
4108 | Error moving the shutter | Separator exit sensor not left when transporting the plate to the load table plate | ||
4109 | Paper sheet lost when separating | When depositing the paper sheet, the vacuum shows that the sheet was lost during transfer into the waste container | ||
4110 | Error initializing the stripper unit | Stripper unit did not arrive at the init position during initialization | ||
4111 | Error initializing the stripper unit | Unable to quit the init sensor of the stripper unit | ||
4112 | Error moving the stripper unit into working position | Unable to quit the parking sensor of the stripper unit | ||
4113 | Error moving the stripper unit | Unable to get to the parking sensor of the stripper unit | ||
4115 | Moving the stripper unit into the parking position caused an error several times | Moving the stripper unit into the parking position caused an error several times | ||
4116 | A sensor was not reached while the stripper unit was moving to its park position | The light barrier of the park sensor was not detected while the stripper unit was moving to its park position | ||
4117 | A sensor was not reached during initialization of the stripper unit | The light barrier of the park sensor was not detected during initialization of the stripper unit | ||
4118 | A sensor was not reached during normalization of the shutter | A sensor was not reached during normalization of the shutter | ||
4119 | A sensor was not reached during initialization of the shutter | The zero light barrier was not detected during initialization of the shutter | ||
4120 | Error initializing the cassette shutter | Cassette shutter motor did not arrive at the init position during initialization | ||
4121 | Error initializing the cassette shutter | Unable to quit the init position when initializing the cassette shutter motor | ||
4122 | Error while preparing cassette shade drive for taking a new cassette | Sensor could not detect the requested phase 1 during the specified number of attempts during initialization of the cassette shade drive | ||
4123 | Error while preparing cassette shade drive for taking a new cassette | Sensor could not detect the requested phase 2 during the specified number of attempts during initialization of the cassette shade drive | ||
4124 | A sensor was not reached during initialization of the cassette shade drive | The light barrier of the close sensor was not detected during initialization of the cassette shade drive | ||
4130 | Error moving the suck bar | The suck bar did not arrive in its new position during the expected time | ||
4133 | Error lowering the suck bar | The suck bar is not at its bottom position as expected | ||
4134 | Error moving the suck bar | The suck bar is not at the middle position as expected | ||
4135 | Error lifting the suck bar | The suck bar is not at the top position as expected | ||
4136 | Error moving the suck bar | The suck bar does not move | ||
4137 | Error setting the suck bar parameters | A command to the suck bar returned an invalid command | ||
4138 | While separating, double sheet error Paper under plate occurred several times without a plate being present | While separating, double sheet error Paper under plate occurred several times without a plate being present | ||
4139 | A piece of paper, located on the Jalousie, couldn’t fix by the suck bar | A piece of Paper couldn’t move from the suck bar to the Jalousie suction bar | ||
4140 | Error setting the separator ejector parameters | Invalid command encountered when enabling the ejector’s blowing function | ||
4141 | Error setting the separator ejector parameters | Invalid command encountered when enabling the ejector’s suction function | ||
4142 | Error setting the separator ejector parameters | Invalid command encountered when actuating the compressed air supply of the ejector’s suck bar | ||
4143 | Error setting the separator ejector parameters | Invalid command encountered when actuating the compressed air supply of the ejector’s suction bar | ||
4144 | Vacuum error signaled by vacuum sensor. Unable to suck and hold the material or material lost | The vacuum sensor of the separator detected an insufficient vacuum | ||
4152 | Error setting the double sheet sensor parameters | Invalid command encountered when selecting the double sheet sensor | ||
4153 | No or not enough compressed air | Poll of compressed air status result: no compressed air | ||
4154 | Error separating. A double sheet detected cannot be separated because the suction bar is carrying material already | |||
4155 | A double sheet detected on the jalousie. The material could not be separated | The double sheet must be removed manually by hand | ||
4156 | A double sheet was detected on the Jalousie. The material couldn’t be split | The double sheet couldn’t fix by the suck bar – it must be removed by hand | ||
4157 | A double sheet was detected on the Jalousie. The material couldn’t be split | The double sheet couldn’t fix by the suck bar – it must be removed by hand | ||
4161 | Tray empty. No material on the active tray | No material found when reading the tray fill level | ||
4162 | A detected double sheet on the Jalousie couldn’t move to the Load Table | A double sheet wasn’t detected from the exit-sensor of the separator | ||
4163 | A double sheet was detected on the Jalousie. The material couldn’t be split within several tries | The double sheet couldn’t be split within several tries – it must be removed by hand | ||
4164 | While checking the material at the suction bar, an error with the vacuum occurred | |||
4165 | While sucking the paper with the suck bar, a vacuum error occurred | There was no vacuum at the suction bar | ||
4166 | The paper could not be removed, because the cassette was not open | |||
4167 | While loading and locking the cassette an error occured inside the SCL | |||
4171 | Clamp jaw unit error | Unable to close the clamp jaw | ||
4172 | Clamp jaw unit error | Unable to open the clamp jaw unit – the unit will not release the plate | ||
4173 | Error closing the clamp jaw unit | Unable to close the clamp jaw unit during the expected time | ||
4174 | Error closing the clamp jaw unit | Unable to open the clamp jaw unit during the expected time | ||
4181 | No material found in the cassette | No material was detected during check of cassette level | ||
4182 | Almost no material in the cassette | A check of the cassette level detected only a few plates still in the cassette. The number has fallen below the set alert level | ||
4183 | The waste container is full | A check of the waste container level detected that the container is full | ||
4184 | The waste container is almost full | A check of the waste container level detected that the set alert level was exceeded | ||
4190 | Error setting the waste container parameters | Invalid command encountered when opening / closing the waste container | ||
4191 | Unable to open the waste container | The waste container could not be opened because it was impossible to move the shutter into the specified position | ||
4192 | Waste container open | Could not open the cassette because the waste container was not closed | ||
4193 | Vacuum error at the suction bar. Could not suck the material to the bar or the material was lost | Vacuum sensor detected that the vacuum was too low when the suction bar of the separator was used | ||
4194 | Vacuum error after raising the suction bar. Could not suck the material to the bar or the material was lost | Vacuum sensor detected that the vacuum was too low after raising the suction bar | ||
4195 | Configuration error – unknown machine type | Invalid machine type set | ||
4196 | Error separating | Plate lost while separating or during transport to the entry of the load table plate. The plate did not arrive at the relevant sensor | ||
4197 | Error separating | Material lost when lifting it out of the tray | ||
4198 | An error occurred during initialization or error handling. Material was found on the shutter | Material was found on the shutter during initialization or error handling. The material is to be removed by the operator | ||
4201 | Unable to determine the position of the load table plate | Both load table plate position sensors output the same signal | ||
4202 | Error moving the load table | Timeout encountered when swivelling/moving the load table | ||
4203 | The load table fans are not working | |||
4204 | Error moving the plate holder | Timeout encountered when lifting/lowering the plate holder | ||
4205 | Error initializing the plate holder | The plate holder did not move away from its init sensor | ||
4206 | Error initializing the plate drive motor | The plate holder did not move up to its init sensor | ||
4207 | Error initializing the plate drive motor | Initialization of the plate drive motor failed. Absolute positioning of the plate holder is not possible | ||
4208 | No plate on the load table | The procedure requires a plate but none has been detected | ||
4209 | Error initializing the center unit | The center unit did not move away from its init sensor | ||
4210 | Error initializing the center unit | The center unit did not move up to its init sensor | ||
4211 | Material transport error | Error transporting the plate from the load table to the conveyor | ||
4212 | Plate not in the gripper | The plate did not move up to the grip sensor | ||
4213 | The plate did not move up to the grip sensor | Wrong width of plate. See the log file for further details | ||
4214 | Load table process error | A signal expected from the load table holder sensor not received | ||
4215 | Error initializing the load table | The states of the load table sensors have been checked. The result is an impossible combination | ||
4226 | Double sheet detected on load table during material transport to recorder | Please remove the material manually by hand | ||
4227 | The load table can not be moved, because material was detected between separator and load table | Material was detected in light barrier of the separator. The material is to be removed by the operator before moving the load table | ||
4301 | Error moving the conveyor | Timeout lifting/lowering the conveyor table | ||
4302 | Error initializing the conveyor roller motor | Initialization of the conveyor roller motor failed | ||
4303 | Error transporting the plate from the conveyor to the load table | Plate transport from the conveyor to the load table is not possible. The plate has left the range of the entry sensor already | ||
4304 | Error centering the plate on the conveyor | Unable to fully load the plate onto the conveyor. The conveyor entry sensor is not free | ||
4305 | No plate on the conveyor | The procedure requires a plate but none has been detected | ||
4306 | Configuration error – no valid assembly position of the online processor | Assembly position of the online processor wrong or not specified | ||
4307 | Error centering the plate on the conveyor | Conveyor center sensor not enabled | ||
4308 | Error initializing the conveyor slider | The conveyor slider did not move away from its init sensor | ||
4309 | Error initializing the conveyor slider | The conveyor slider did not move up to its init sensor | ||
4310 | Error initializing the conveyor slider | Initialization of the conveyor slider motor failed | ||
4311 | Error unloading the plate | Signal expected from the conveyor entry sensor not received | ||
4312 | Conveyor process error | Signal expected from the conveyor slider init sensor not received | ||
4313 | Error actuating the online processor | No ON signal of the online processor | ||
4314 | Error actuating the online processor | No connect signal of the online processor | ||
4315 | Configuration error – wrong online processor interface set | The set online processor interface is unknown | ||
4316 | Error unloading the plate | Error centering the plate on the conveyor. The computed correction exceeds the maximum | ||
4317 | Error unloading the plate | Signal expected from the conveyor exit sensor not received | ||
4318 | Error unloading the plate | Signal expected from the conveyor center sensor not received | ||
4319 | Error initializing the conveyor | The states of the conveyor sensors have been checked. The result is an impossible combination | ||
4320 | Error centering the plate on the conveyor | Unable to readjust the plate onto the conveyor. The plate is expected on the entry sensor but isn’t there | ||
4401 | An error occurred while swinging out the cassette drive | One of the two cassette drives did not reach its swing-out position in the allotted time | ||
4402 | An error occurred while swinging out the cassette drive | One of the two cassette drives did not leave its swing-out position in the allotted time | ||
4403 | An error occurred during the cassette drive setup | An invalid command for the cassette drive was detected | ||
4404 | An error occurred while evaluating the current cassette position | The sensors for the horizontal cassette position returned an invalid position | ||
4405 | No cassette was detected at the MCL exit when conveying a cassette from the SCL to the MCL | The exit sensor of the MCL did not detect a cassette | ||
4406 | No cassette was detected at the MCL entry when loading a cassette | The cassette drive sensor (perhaps the entry sensor as well) did not detect a cassette | ||
4407 | No fully loaded cassette was detected while unloading a cassette from the MCL | |||
4408 | A cassette could not be positioned correctly while loading it from the SCL | The specified number of attempts to position the cassette was exceeded | ||
4409 | A cassette could not be positioned correctly while loading it from the trolley | The specified number of attempts to position the cassette was exceeded | ||
4410 | Error closing the inlet door | The inlet door did not reach the position in the allotted time | ||
4411 | Error opening the inlet door | The inlet door did not reach the position in the allotted time | ||
4412 | An error occurred while evaluating the current inlet door position | The sensors for the inlet door position returned an invalid position | ||
4413 | An error occurred during the setup of the inlet door drive | An invalid command for the inlet door drive was detected | ||
4414 | The inlet door was not open before a cassette was unloaded to the trolley | |||
4415 | The inlet door was not closed before the elevator moved | |||
4420 | Error initializing the elevator | The elevator init sensor was not reached | ||
4421 | Error initializing the elevator | The elevator init sensor was not left | ||
4422 | An error occurred while evaluating the current elevator position | The sensors for the vertical cassette position detected an invalid position | ||
4423 | Failed to find cause of aborted movement after elevator or cassette drive finished moving | The cause was an undefined event | ||
4424 | The elevator or cassette drive did not finish moving by reaching a sensor | |||
4425 | An error occurred while moving the elevator | The error bit of the elevator motor is active | ||
4426 | A safety error occurred before the elevator moved | One of the two cassette drives is not swung out | ||
4427 | A safety error occurred before the elevator moved | The cassette in the SCL was not locked | ||
4428 | An error occurred while evaluating the current elevator position | The sensors for the vertical cassette position returned an invalid position | ||
4429 | An error occurred during the elevator setup | An invalid command for the elevator was detected | ||
4440 | No fully loaded cassette was detected before unloading a cassette from the MCL to the SCL or the trolley | |||
4441 | No fully loaded cassette was detected after loading a cassette from the SCL or the trolley to the MCL | |||
4442 | No cassette was detected at the MCL entry sensor before loading a cassette from the SCL to the MCL | |||
4443 | No cassette was detected at the MCL exit sensor after unloading a cassette from the MCL to the SCL | |||
4444 | No cassette was detected at the MCL entry sensor before loading a cassette from the trolley to the MCL | |||
4445 | No cassette was detected at the MCL entry sensor after unloading a cassette from the MCL to the trolley | |||
4446 | A cassette was detected to be not fully loaded to its position before the elevator moved | |||
4447 | The cassette is not in valid position | |||
4448 | No trolley was found in front of the MCL before unloading a cassette from the MCL | |||
4449 | A cassette was detected in the SCL before unloading a cassette from the MCL to the SCL | |||
4450 | The elevator could not be moved or movement had to be stopped too soon because the cassette drive was no longer swung out | |||
4451 | An error occurred, at least one safety relay of the MCL is open | |||
4460 | Movement of elevator started, duration approximately 90 sec | |||
4461 | Movement of elevator started, duration approximately 60 sec | |||
4462 | Movement of elevator started, duration approximately 30 sec | |||
4500 | No tray with the requested material | Further processing will be paused until a tray with the requested material has been put in | ||
4501 | The waste container is open | Further processing will be paused until the waste container has been closed | ||
4502 | The load table is not free. The system may be waiting for a plate to be moved on into the online processor | Further processing will be paused until the load table is free again | ||
4503 | The conveyor is not free. The system may be waiting for a plate to be moved on into the online processor | Further processing will be paused until the conveyor is free again | ||
4504 | The trolley is not in loading/unloading position | Further processing will be paused until the trolley is in the correct position | ||
4505 | Online processor not ready – no connect signal | Further processing will be paused until a connect signal has been received from the online processor | ||
4506 | The online processor is off | Further processing will be paused until the online processor is on and has sent a ready signal | ||
4507 | The online processor is busy | Further processing will be paused until the state of the online processor has changed from Busy to Not Busy | ||
4508 | The paper container is full | Further processing will be paused until the paper container has been opened and emptied | ||
4509 | Tray empty | Further processing will be paused until the tray has been removed, filled with material and put back in | ||
4510 | No or not enough compressed air | Further processing will be paused until the pressure level has reached the required value | ||
4511 | Remove the cassette | Further processing will be paused until the cassette has been removed | ||
4512 | Insert required plate to bypass | Insert required plate to bypass | ||
4513 | Remove plate from bypass. Plate width is not as requested | Remove plate from bypass | ||
4520 | Shaft data inconsistency detected. Rescan initiated (approx. 120 sec.) | |||
4530 | Error executing comand | The DAL command is not implemented | ||
4531 | Error executing command | The DAL command was rejected | ||
4532 | Error loading/unloading a cassette | Loading/unloading the cassette to the specified tray was impossible as the tray already contained a cassette | ||
4533 | Error loading/unloading a cassette | The specified tray number is out of ra | ||
4534 | Error loading/unloading a cassette | The specified tray type is incorrect | ||
4535 | Error loading/unloading a cassette | The state of the specified tray is incorrect | ||
4536 | Initialization failed | The initialization loop exceeded the maximum | ||
4537 | Error Correction failed | The error correction loop exceeded the maximum | ||
4538 | Shut down failed | The shutdown loop exceeded the maximum | ||
4988 | An error was detected in the horizontal drive of the MCL | The elevator’s motor control detected an error and switched itself off | ||
4989 | Error initializing a motor | Unable to quit the home sensor | ||
4990 | Error initializing a motor | Expected home sensor not found at the target position | ||
4991 | Error controlling a motor | Expected sensor not found at the target position | ||
4992 | Error controlling a motor | Invalid parameter found when computing the data for stepper motor actuation | ||
4993 | Error controlling a motor | No actuation data found when starting the stepper motor | ||
4994 | Error controlling a motor | Insufficiently larger memory range found when computing the data for stepper motor actuation | ||
4995 | Error controlling a motor | Absolute motor positioning not possible, the motor is to be initialized first | ||
4996 | Error controlling a motor | Timeout actuating the stepper motor | ||
4997 | Error controlling a motor | Invalid minimum frequency for actuating the stepper motor | ||
4998 | Error controlling a motor | Invalid parameter found when computing the data for stepper motor actuation | ||
4999 | Error controlling a motor | Error computing the data for actuating the stepper motor |