Error:            Description:
 Ex101
 Nip roller does not ascend
 Ex102  Nip roller does not descend
 Ex103  Transport unit does not ascend
 Ex104  Transport unit does not descend
 Ex105  Trail clamp arm does not ascend
 Ex106  Trail clamp arm does not descend
 Ex107  Squeeze roller does not descend
 Ex108  Squeeze roller does not ascend
 Ex109  Trail clamp cannot be locked
 Ex10a  Trail clamp cannot be unlocked
 Ex10b  Balancer drive pin cannot be initialized
 Ex10c  Both of the Home and Away side drive pins for the balancer can not be pulled out
 Ex10d  Both of the Home and Away side drive pins for the balancer can not be inserted
 Ex110  Shutter does not open
 Ex111  Shutter does not close
 Ex112  Plate size (in the Y direction) is shorter than the set value
 Ex113  When the plate is unloaded, the plate pass sensor (PH54-2) does not switch to ON
 Ex114  Not bring down squeeze at loading
 Ex115  Plate size (in the Y direction) is longer than the set value
 Ex116  Servo status is illegal
 Ex117  Servo status is error
 Ex118  Servo alarm
 Ex11a  Drum speed is set beyond the permitted rate of the servo controller
 Ex11b  Current drum’s encoder pulse is beyond 4000
 Ex11c  Error has occurred during drum positioning
 Ex11d  When the clamp is locked, some tail clamps are detected on the clamp arm, or when the clamp is unlocked, some tail clamps are not detected on the clamp arm
 Ex11e  Drum’s encoder pulse is beyond the permitted range after drum positioning
 Ex11f  Plate cannot be transferred into the transport unit
 Ex120  Balancer pin cannot be detected before inserted (Home side)
 Ex121  Balancer pin cannot be detected before pulled out (the balancer is not moving) (Home side)
 Ex122  Clamp arm and squeeze roller do not descend
 Ex123  Clamp arm and squeeze roller do not ascend
 Ex126  There was no plate to move to the shutter
 Ex127  Servo controller does not enter the “Ready” status
 Ex128  No balancer has been detected by the balancer search sensor
 Ex129  Error has occurred on the Home side of the alignment plate (while the alignment plate is returning to its origin)
 Ex12a  Error has occurred on the Away side of the alignment plate (while the alignment plate is returning to its origin)
 Ex12b  Error has occurred on the Home and Away sides of the alignment plate (while the alignment plate is returning to its origin)
 Ex12c  Error has occurred on the Home side of the alignment plate (while alignment is performed)
 Ex12d  Error has occurred on the alignment plate (while alignment is performed)
 Ex12e  Error has occurred on the Home and Away sides of the alignment plate (when alignment is performed)
 Ex12f  Plate has not transferred to the punch unit
 Ex139  After a plate is transferred to the gripper clamp, the plate detection sensor (PH25H/A) does not switch to ON
 Ex13a  When the clamp arm is lowered, the sensor (to detect whether the clamp arm pins are hooked on the clamp properly) has been turned
 Ex13b  The specified encoder pulse for the drum is beyond 4000
 Ex13c  The transport unit’s Away side is not moving during its operation
 Ex13d  The transport unit’s Home side is not moving during its operation
 Ex13e  Error has occurred on the Home side of the alignment plate (while the alignment plate is finely returning to its origin)
 Ex13f  Error has occurred on the Away side of the alignment plate (while the alignment plate is finely returning to its origin)
 Ex140  Error has occurred on the Home and Away side of the alignment plate (while the alignment plate is returning to its origin)
 Ex141  A plate remains in the transport unit when the machine received a request command
 Ex142  A plate remains in the transport unit during error handling
 Ex143  A plate remains on the discharge table in the transport unit
 Ex144  A plate remains on the insertion table in the transport unit
 Ex145  Plate cannot be moved onto the discharge table during initialization
 Ex146  Plate cannot be moved onto the insertion table
 Ex147  Balancer search operation has not been completed properly
 Ex148  When the transport unit descends, only the Home side Down sensor in the transport unit is turned ON
 Ex149  When the transport unit descends, only the Away side Down sensor in the transport unit is turned ON
 Ex14a  When the transport unit ascends, only the Home side UP sensor in the transport unit is turned ON
 Ex14b  When the transport unit ascends, only the Away side UP sensor in the transport unit is turned ON
 Ex14c  Front, rear or side cover is open. (Some interlock switches are OFF)
 Ex14d  A fuse on the relay board was blown. (home)
 Ex14e  Thumbscrew is not tightened securely on the rear cover. (The servo stop switch is OFF)
 Ex14f  A plate exists on the discharge table in the transport unit during initialization
 Ex150  A plate exists on the insertion table in the transport unit during initialization
 Ex151  Number of balancers is not sufficient. (The number of balancers checked by the balancer search sensor was one, two or three for both the Home and Away sides)
 Ex152  Clamp arm is not in the UP position
 Ex153  A fuse on the relay board was blown. (away)
 Ex154  Blower is turned off, but signal does not change
 Ex155  Tail clamps are missing during initialization
 Ex156  The size check program of the cetering function detects that the measured plate size is longer than the expected one
 Ex157  The size check program of the cetering function detects that the measured plate size is shorter than the expected one
 Ex158  Both of Home and Away size check sensors are on before starting the centering program
 Ex159  Auto-loader is stopped by a interlock OFF
 Ex15a  The drum is rotated to “balance pin before inserted”, but status of Servo controller (SVC) is not changed to “Ready”.[away]
 Ex15b  The drum is rotated to “balance pin after inserted”, but status of Servo controller (SVC) is not changed to “Ready”.[away]
 Ex15d  During plate loading, double plate loading is detected
 Ex15e  The loaded plate is floating from the drum is detected during drum spinning
 Ex15f  The drum can not be spined up because the Away-Upper sensor of the clamp arm is off
 Ex160  The drum can not be spined up because the Home-Upper sensor of the clamp arm is off
 Ex161  The drum can not be spined up because the balancing pin (Away side) is not in the waiting position
 Ex162  The drum can not be spined up because the balancing pin (Home side) is not in the waiting position
 Ex163  The drum can not be spined up because the Upper sensor of the squeeze roller is off
 Ex165  The drum is rotated to the “lead clamp position”, but the status of the Servo controller (SVC) has not changed to “Ready”
 Ex166  The drum is rotated to the “tail clamp position”, but the status of the Servo controller (SVC) has not changed to “Ready”
 Ex167  The drum is rotated to the “squeeze position”, but the status of the Servo controller (SVC) has not changed to “Ready”
 Ex168  The drum is rotated to the “balance pin before inserted”, but the status of the Servo controller (SVC) has not changed to “Ready”
 Ex169  The drum is rotated to the “balance pin after inserted”, but the status of the Servo controller (SVC) has not changed to “Ready”
 Ex16a  The drum is rotated to the “pick up tail clamp position”, but the status of Servo controller (SVC) has not changed to “Ready”
 Ex16b  The drum is rotated to the “plate removal position”, but the status of the Servo controller (SVC) has not changed to “Ready”
 Ex16c  SVC Error has occurred during drum positioning for the lead clamp
 Ex16d  SVC Error has occurred during drum positioning for the tail clamp
 Ex16e  SVC Error has occurred during drum positioning for the squeeze
 Ex16f  SVC Error has occurred during drum positioning for the balance pin insertion
 Ex170  SVC Error has occurred during drum positioning for the balance pin pull out
 Ex171  SVC Error has occurred during drum positioning for the picking up tail clamp
 Ex172  SVC Error has occurred during drum positioning for the plate removal
 Ex173  Time-out error has occurred during drum positioning (Lead clamp position)
 Ex174  Time-out error has occurred during drum positioning (Tail clamp position)
 Ex175  Time-out error has occurred during drum positioning (Squeeze position)
 Ex176  Time-out error has occurred during drum positioning (Balance pin before inserted)
 Ex177  Time-out error has occurred during drum positioning (Balance pin after inserted) (Home)
 Ex178  Time-out error has occurred during drum positioning (Pick up tail clamp)
 Ex179  Time-out error has occurred during drum positioning (Plate removal)
 Ex17a  After verifying the removal of the plate, press the OK button. When the OK button is pressed, initialization begins
 Ex17b  PH62A-sensor is illegal. The sensor detects a plate during initialization
 Ex17c  PH25H-sensor is illegal. The sensor detects a plate during plate loading
 Ex17d  Time-out error has occurred during drum positioning.(balance pin before inserted) (Away)
 Ex17e  Time-out error has occurred during drum positioning.(balance pin after inserted) (Away)
 Ex180  Drum does not start rotating at high-speed
 Ex181  Drum does not rotate at the specified high-speed
 Ex182  Error has occurred after the drum rotated at the specified high-speed
 Ex183  Drum cannot be stopped when rotating at high-speed
 Ex184  Drum operation is halted with an emergency stop command
 Ex185  Drum operation is stopped with an abort command
 Ex186  Drum’s vacuum pressure is not sufficient
 Ex187  Error has occurred on the blower or the power supply of the blower is OFF
 Ex188  Drum operation is halted due to low pressure in the drum
 Ex189  Door is open
 Ex18a  Door does not open
 Ex18b  Transport tasks: Parameter error
 Ex18c  Error has occured on the blower. Please turn off this machine, and turn on after waiting 10 seconds. Also, confirm whether or not the connector doesn’t come off
 Ex18d  The drum can not be spun up, because some of the interlock switches are OFF, or some of the actuator’s sensors are damaged, or the blower is damaged
 Ex18e  Door does not open, because some of the interlock switches are OFF (front cover or rear cover is open)
 Ex190  Clamp arm does not descend (Home side)
 Ex191  Clamp arm does not descend (Away side)
 Ex192  Clamp arm does not ascend (Home side)
 Ex193  Clamp arm does not ascend (Away side)
 Ex194  When the clamp arm is lowered, the sensor (to detect whether the clamp arm pins are hooked on the clamp properly) has been turned ON (Away side)
 Ex195  Trail clamp cannot be locked (Home side)
 Ex196  Trail clamp cannot be locked (Away side)
 Ex197  Trail clamp cannot be unlocked (Home side)
 Ex198  Trail clamp cannot be unlocked (Away side)
 Ex199  Balancer drive pin cannot be inserted (Home side)
 Ex19a  Balancer drive pin cannot be inserted (Away side)
 Ex19b  Balancer drive pin cannot be pulled out (Home side)
 Ex19c  Balancer drive pin cannot be pulled out (Away side)
 Ex19d  Balancer pin cannot be detected before insertion (Away side)
 Ex19e  Balancer pin cannot be detected before pull out (the balancer is not moving) (Away side)
 Ex19f  No balancer has been detected by the balancer search sensor (Home side)
 Ex1a0  No balancer has been detected by the balancer search sensor (Away side)
 Ex1a1  Number of balancers is not sufficient. (Home side)
 Ex1a2  Number of balancers is not sufficient. (Away side)
 Ex1a3  Rear cover is open (Some interlock switch are OFF)
 Ex1a4  Away side cover is open (Some interlock switch are OFF)
 Ex1a5  Front cover is open (Some interlock switch are OFF)
 Ex1a6  A plate cannot be carried into the transport unit
 Ex1a7  A plate cannot be carried to sensor PPH50-2
 Ex1a8  Auto-loader is not turned on, or some interlock switches on Auto-loader are OFF
 Ex1a9  Cassete carrier was removed
 Ex1aa  The door of the cassette part is open
 Ex1ab  Rear-cover of Auto-loader was opend
 Ex1ac  Top cover was opened
 Ex1ad  A slipping paper under a plate was detected. Or a plate size (in the Y direction) is shorter than the set value
 Ex1ae  A slipping paper on a plate was detected. Or a plate size (in the Y direction) is shorter than the set value
 Ex1b0  Time-out error has occurred when Punch 1 is activated
 Ex1b1  Time-out error has occurred when Punch 2 is activated
 Ex1b2  Time-out error has occurred when Punch 3 is activated
 Ex1b3  Time-out error has occurred when Punch 4 is activated
 Ex1b4  Time-out error has occurred when Punch 5 is activated
 Ex1b5  Time-out error has occurred when Punch 6 is activated
 Ex1b6  Time-out error has occurred when Punch 7 is activated
 Ex1b7  Time-out error has occurred when Punch 8 is activated
 Ex1b8  Time-out error has occurred when Punch 9 is activated
 Ex1b9  Time-out error has occurred when Punch A is activated
 Ex1ba  Time-out error has occurred when Punch B is activated
 Ex1bb  Time-out error has occurred when Punch C is activated
 Ex1bc  Nip roller(Unload) does not ascend
 Ex1bd  Nip roller(Unload) does not descend
 Ex1be  Unload path does not ascend
 Ex1bf  Unload path does not descend
 Ex1c0  Time-out error has occurred when the caterpillar motor is activated
 Ex1c1  Error has occurred on the caterpillar motor (while the alignment plate is finely returning to its origin)
 Ex1c2  Door does not open
 Ex1c3  Door does not close
 Ex1c7  Plate is not transferred to the punch unit [PH59]
 Ex1c8  After a plate is transferred to the gripper clamp, the plate detection sensor (PH25H/A) does not switch to ON [PH59]
 Ex1c9  When the transport unit descends, plate cannot be transferred into the transport unit
 Ex1ca  When the plate is unloaded, PH53-sensor does not switch to ON
 Ex1cb  Opened shutter obstructs trans path driving
 Ex1cc  Trail clamp arm obstructs trans path driving
 Ex1cd  A plate remains in a machine
 Ex1d0  Transfer operation is halted with an abort command
 Ex1d1  Transport tasks are being processed
 Ex1d2  Transport tasks are not being processed
 Ex1d3  Transport tasks: Message order error
 Ex1d4  Transport system is not initialized
 Ex1e0  SVC User constant breakdown
 Ex1e1  SVC User constant setting error
 Ex1e2  SVC over-current
 Ex1e3  SVC detection of regenerative error
 Ex1e4  SVC postion error pulse overflow
 Ex1e5  SVC Main circuit voltage error detection
 Ex1e6  SVC over speed
 Ex1e7  SVC overloaded (high load)
 Ex1e8  SVC overloaded (low load)
 Ex1e9  SVC stauts 99h
 Ex1ea  SVC heat sink has overheated
 Ex1eb  SVC stauts b1h
 Ex1ec  SVC is out of control
 Ex1ed  SVC phase error has been detected in the encoder
 Ex1ef  SVC A and B phase for the encoder has broke down
 Ex1f0  SVC C phase for the encoder has broke down
 Ex1f1  SVC Power line Open phase
 Ex1f3  SVC An instantaneous loss of power has occurred
 Ex1f4  SVC unknown error
 Ex1f5   Detection of servo encorder error
 Ex200  Exposure operation is interrupted with an abort command
 Ex201  Exposure processing task is now processing another command
 Ex202  Cancellation requested while processing was not being performed
 Ex203  PGON is not asserted
 Ex204  START signal is not asserted
 Ex205  START signal is not negated
 Ex206  Test pattern; Data is not transferred
 Ex207  Test pattern; Data transfer is not completed
 Ex208  Reset procedure for TB64 board is not completed
 Ex209  The set value for the drum rotation speed is too large
 Ex20a  No plate edge is detected (when the plate edge sensor moves to the Away side)
 Ex20b  No plate edge is detected (when the plate edge sensor is returning to the Home side)
 Ex20c  Recording head has traveled beyond the limit (on the Away side)
 Ex20d  Recording head has traveled beyond the limit (on the Home side)
 Ex20e  Recording head positioning range error
 Ex20f  Recording head has not been positioned at its origin. (Origin sensor does not turn OFF)
 Ex210  Recording head has not been positioned at its origin. (Origin sensor does not turn ON)
 Ex211  Emergency stop is requested for the secondary-scanning motor
 Ex212  Secondary-scanning motor is deactivated with an abort command
 Ex213  Secondary scanning motor is illegal
 Ex214  Exposure in the secondary scanning direction exceeds the effective image ouput range
 Ex215  FPGA sequence error
 Ex216  Time-out error has occurred when the secondary scanning motor is activated
 Ex217  EZ search has not detected the ORG sensor
 Ex218  EZ search has not detected the EZ sensor
 Ex219  When the CAL sensor search was executed, the maximum light intensity was less than 50 mW
 Ex21a  When the CAL sensor search was executed, the light intensity at the measurement starting point was the maximum
 Ex21b  When the CAL sensor search was executed, the light intensity at the measurement end point was the maximum
 Ex21c  CAL sensor search has not detected the over travel limit switch on the recording head’s Home side
 Ex21d  Test pattern parameter error
 Ex21e  PGON signal is not negated
 Ex21f  Secorndary direction origin point setup procedure failure (The calibrated origin point is not the same as logical origin point)
 Ex220  After an image data transfer from RIP is interrupted, it isn’t resumed
 Ex221  Cooling fan for TB64 board is illegal
 Ex222  Hungup was detected
 Ex223  The version of TB64 board and FES board is inharmonious
 Ex224  Machine and firmware is inharmonious
 Ex300  Both of plate pad and paper pad are not in original point
 Ex301  After a slipping paper is removed, plate cannot be detected
 Ex302  A slipping paper on a plate was detected. Or a plate size (in the Y direction) is shorter than the set value
 Ex303  Plate pad cannot be initialized
 Ex304  Plate pad cannot carry a plate
 Ex305  During the carring a plate, plate pad dropped the plate
 Ex306  Paper pad cannot be initialized
 Ex307  Air pressure in the plate pad does not go down
 Ex308  Air pressure in the paper pad does not go down
 Ex309  Time-out error has occurred when plate pad was moved
 Ex30a  Time-out error has occurred when paper pad was moved
 Ex30b  Time-out error has occurred when plate pad was moved intermittently
 Ex30c  Time-out error has occurred when paper pad was moved intermittently
 Ex30e  During the removing a papaer, PH90 does not switch to ON
 Ex30f  During the removing a papaer, PH90 does not switch to OFF
 Ex310  Rear cover of auto-loader is open
 Ex311  Top cover of auto-loader is open
 Ex312  Cassette carrier is not set
 Ex313  A plate remains in the bridge unit
 Ex314  An interleaf remains in the paper exit
 Ex315  Nip roller does not ascend or some interlock switch are illegal, or emergency switch is turned ON
 Ex316  Nip roller does not descend
 Ex317  Auto-loader is not turned on, or all interlock switch are OFF
 Ex318  A plate cannot be carried to the bridge-passing sensor
 Ex319  The plate pad went down from the original point
 Ex31a  The paper pad went down from the original point
 Ex31b  Rear-cover of Auto-loader was opened
 Ex31c  Top cover was opened
 Ex31d  Door was opened
 Ex31e  Cassete carrier was removed
 Ex31f  During the carring a paper, paper pad dropped the paper
 Ex320  Plate pad dropped a plate before the plate pad reached the intermediate sensor
 Ex321  A slipping paper on front of a plate was detected
 Ex322  A slipping paper under front of a plate was detected
 Ex323  Intermediate sensor is OFF
 Ex324  Power switch was turned off while Auto-loader was moving
 Ex325  A plate cannot be carried to the intermediate sensor
 Ex326  A slipping paper under a plate was detected. Or a plate size (in the Y direction) is shorter than the set value
 Ex327  The bridge-passing sensor does not turn OFF (for Jig mode)
 Ex328  Door is open
 Ex32c  The nip-roller for paper discharge cann’t be opened
 Ex340  Door is open
 Ex341  The interlock switch-3 is OFF
 Ex342  The interlock switch-2 is OFF
 Ex343  The interlock switch-1 is OFF
 Ex344  A fuse on the relay board at home side has blown
 Ex345  A fuse on the relay board at away side has blown
 Ex346  Nip roller does not descend
 Ex347  Nip roller does not ascend
 Ex348  Shutter does not open
 Ex349  Shutter does not close
 Ex380  The door of the cassette part is open
 Ex381  Time-out error has occurred when lift was initialized
 Ex382  Time-out error has occurred when lift was moved
 Ex383  Though the lift was initialized, the origin sensor is not ON
 Ex384  The lift is not in the position where it is specified
 Ex385  Already, there has been a cassette on the lift
 Ex386  There are some cassettes which aren’t being set properly
 Ex387  MA-L can’t be initialized because some cassettes are not in the lift or the cassette properly
 Ex388  There is no cassette in the specified cassette slot
 Ex389  There is no cassette on the lift
 Ex38a  Lift has traveled beyond the limit (on the Up side)
 Ex38b  Lift has traveled beyond the limit (on the Down side)
 Ex38d  A cassette is already in the place to return a cassette
 Ex38e  A lift can’t be raised and lowered because some cassettes are not in the lift or the cassette properly
 Ex38f  Time-out error has occurred when a cassette was moved to cassette part
 Ex390  Time-out error has occurred when a cassette was moved to lift
 Ex391  Either plate pad or paper pad is not in original point
 Ex392  An ineffective cassette number was indicated
 Ex393  Cassette has traveled beyond the limit (on the Lift side)
 Ex394  Cassette has traveled beyond the limit (on the Cassette side)
 Ex395  MA-L can’t be initialized because some cassettes can’t be returned to the origin
 Ex396  Though there is a cassette on the lift, the place to return the cassette isn’t vacant
 Ex397  Though the movement of the lift was finished, the lift position sensor at the target position is not on
 Ex398  MA-L Servo alarm
 Ex399  The belt broke
 Ex400  Plate has already been loaded
 Ex401  Plate has not been loaded
 Ex402  Door is open
 Ex403  Dump interleaves from the collection box
 Ex600  Either the conveyor, processor, or stocker is not turned on, or is in the busy status or error status
 Ex601  Either the conveyor, processor, or stocker is not turned on, or is in the busy status or error status
 Ex602  The plate cannot be transferred into the AT unit
 Ex603  The plate cannot be transferred completely into the AT unit
 Ex606  Error
 Ex607  Busy
 Ex608  Error
 Ex609  Busy
 Ex60a  Error
 Ex60b  Busy
 Ex60c  Error occurred in ATM while a plate was carried to ATM
 Ex60d  When the plate is unloaded, the plate pass sensor (PH70) does not switch to ON
 Ex80d  The result of the calculation “Initial value + increment value * (repetition – 1)” exceeds the upper limit value
 Ex80e  (The result of the calculation “Exposure starting point + (pattern width + gap) * (repetition – 1)” exceeds the plate size
 Ex80f  The specified plate is not linked with the printing-machine’s data
 Ex810  Perform initialization at the service screen
 Ex811  No plate is set at inlet of transport unit
 Ex812  Plate (printer) size specified by the host computer is not registered
 Ex813  Image size specified by host computer is larger than allowable output image size
 Ex814  Current offset of printing machine settings cause image to extend off plate
 Ex815  Current paper-position of printing machine settings cause image to extend outside of allowable exposure area
 Ex817  Some LD is nearing the end of its usable life
 Ex818  There are some punch blocks, which have been used for more than the endurance time
 Ex81a  It failed to read the cassette number. It considers that the cassette number is No.1
 Ex81b  Some LD’s cannot be calibrated to the target power
 Ex81c  Some LD’s cannot be calibrated to the target power
 Ex81d  Some LD’s cannot be calibrated to target power
 Ex81e  The temperature of the environment is greater than 28degrees
 Ex81f  The temperature of the environment is less than 18degrees
 Ex820  Sensor for the temperature of the environment has not been connected
 Ex821  Trail clamps are nearing the end of its usable life
 Ex822  Trail clamps have been used for more than the endurance time
 Ex823  Backup/restore of the data on NVRAM can’t be performed, because the Dip-Sw 2 is not on
 Ex824  The backup of the data on NVRAM is not in Flash-Memory
 Ex825  Calibration must be done because there is some LD which doesn’t reach the target power. But, LD calibration can not processed because temperature of LD block is too low
 Ex826  The direction where a connected conveyer can’t be changed is set up in the plate types setting
 Ex827  No response was returned from the conveyor
 Ex828  An error was returned from the conveyer toward the switching command
 Ex829  The conveyer can’t be changed to the direction that is set up in the plate types setting
 Ex82a  Since the light intensity of laser diodes is detected as having deviated more than +-5% from the specified value, the equipment executes the calibration
 Ex82b  The head task was hanged up.
 Ex82c  Head:Iopd data error
 Ex850  Communication with the RAS server was interrupted. (RAS server was turned off or RS-232C cable was drawn out)
 Ex851  No response come from DNS
 Ex852  Communication with the RAS server has resume
 Ex853  It failed in the connection to the rotating light server
 Ex854  The name of the mail server isn’t right
 Ex855  It failed in the connection to the mail server
 Ex856  Mail account was rejected
 Ex857  An error occurred in the transmission of DATA command
 Ex858  An error occurred in the transmission of header
 Ex859  An error occurred in the transmission of body
 Ex85a  An error occurred in the transmission of attached file
 Ex85b  An error occurred in the transmission of TO command
 Ex85c  A command was sent to the SMTP server. But, no answer was returned from the server
 Ex880  Servo pack: Time-out error occurred while receiving data
 Ex881  Servo-Pack:Address error
 Ex882  Servo-Pack:Data error
 Ex883  Servo-Pack:Check sum error
 Ex884  Servo-Pack:Undefined error code
 Ex885  Servo-Pack:Number of received characters are insufficient
 Exd01  Excessive current in the LD drive (driver 1 board)
 Exd02  Excessive current in the LD drive (driver 2 board)
 Exd03  Excessive current in the LD drive (driver 3 board)
 Exd04  Excessive current in the LD drive (driver 4 board)
 Exd05  Driver board temperature error
 Exd08  Irregular peltier
 Exd09  Irregular FES board power supply
 Exd0a  Irregular +9 V power supply
 Exd21  Temperature at the RH base > 35degrees (Temperature of environment > 28degrees)
 Exd22  Temperature at the periphery of the optical unit is high
 Exd25  Sensor for the RH base has not been connected
 Exd28  Temperature of the LD block is low
 Exd30  Writing error occurred when the recording head received the AC command
 Exd31  Writing error on EEPROM
 Exd32  Data error due to a divide-by-zero error
 Exd33  Calibration must be done
 Exd40  Temperature of the LD block is high. block 0
 Exd41  Temperature of the LD block is high. block 1
 Exd42  Temperature of the LD block is high. block 2
 Exd43  Temperature of the LD block is high. block 3
 Exd44  Temperature of the LD block is high. block 4
 Exd45  Temperature of the LD block is high. block 5
 Exd46  Temperature of the LD block is high. block 6
 Exd47  Temperature of the LD block is high. block 7
 Exd48  Temperature of the LD block > 28degrees
(Temperature at the periphery of the optical unit > 35degrees. Temperature of environment ≤ 28degrees.) block 0
 Exd49  Temperature of the LD block > 28degrees
(Temperature at the periphery of the optical unit > 35degrees. Temperature of environment ≤ 28degrees.) block 1
 Exd4a  Temperature of the LD block > 28degrees
(Temperature at the periphery of the optical unit > 35degrees. Temperature of environment ≤ 28degrees.) block 2
 Exd4b  Temperature of the LD block > 28degrees
(Temperature at the periphery of the optical unit > 35degrees. Temperature of environment ≤ 28degrees.) block 3
 Exd4c  Temperature of the LD block > 28degrees
(Temperature at the periphery of the optical unit > 35degrees. Temperature ofenvironment ≤ 28degrees.) block 4
 Exd4d  Temperature of the LD block > 28degrees
(Temperature at the periphery of the optical unit > 35degrees. Temperature of environment ≤ 28degrees.) block 5
 Exd4e  Temperature of the LD block > 28degrees
(Temperature at the periphery of the optical unit > 35degrees. Temperature of environment ≤ 28degrees.) block 6
 Exd4f  Temperature of the LD block > 28degrees
(Temperature at the periphery of the optical unit > 35degrees. Temperature of environment ≤ 28degrees.) block 7
 Exd50  Temperature of the LD block > 28degrees
(Temperature at the periphery of the optical unit ≤ 35degrees. Temperature of environment > 28degrees.) block 0
 Exd51  Temperature of the LD block > 28degrees
(Temperature at the periphery of the optical unit ≤ 35degrees. Temperature of environment > 28degrees.) block 1
 Exd52  Temperature of the LD block > 28degrees
(Temperature at the periphery of the optical unit ≤ 35degrees. Temperature of environment > 28degrees.) block 2
 Exd53  Temperature of the LD block > 28degrees
(Temperature at the periphery of the optical unit ≤ 35degrees. Temperature of environment > 28degrees.) block 3
 Exd54  Temperature of the LD block > 28degrees
(Temperature at the periphery of the optical unit ≤ 35degrees. Temperature of environment > 28degrees.) block 4
 Exd55  Temperature of the LD block > 28degrees
(Temperature at the periphery of the optical unit ≤ 35degrees. Temperature of environment > 28degrees.) block 5
 Exd56  Temperature of the LD block > 28degrees
(Temperature at the periphery of the optical unit ≤ 35degrees. Temperature of environment > 28degrees.) block 6
 Exd57  Temperature of the LD block > 28degrees
(Temperature at the periphery of the optical unit ≤ 35degrees. Temperature of environment > 28degrees.) block 7
 Exd58  Temperature of the LD block > 28degrees
(Temperature at the periphery of the optical unit ≤ 35degrees. Temperature of environment ≤ 28degrees.) block 0
 Exd59  Temperature of the LD block > 28degrees
(Temperature at the periphery of the optical unit ≤ 35degrees. Temperature of environment ≤ 28degrees.) block 1
 Exd5a  Temperature of the LD block > 28degrees
(Temperature at the periphery of the optical unit ≤ 35degrees. Temperature of environment ≤ 28degrees.) block 2
 Exd5b  Temperature of the LD block > 28degrees
(Temperature at the periphery of the optical unit ≤ 35degrees. Temperature of environment ≤ 28degrees.) block 3
 Exd5c  Temperature of the LD block > 28degrees
(Temperature at the periphery of the optical unit ≤ 35degrees. Temperature of environment ≤ 28degrees.) block 4
 Exd5d  Temperature of the LD block > 28degrees
(Temperature at the periphery of the optical unit ≤ 35degrees. Temperature of environment ≤ 28degrees.) block 5
 Exd5e  Temperature of the LD block > 28degrees
(Temperature at the periphery of the optical unit ≤ 35degrees. Temperature of environment ≤ 28degrees.) block 6
 Exd5f  Temperature of the LD block > 28degrees
(Temperature at the periphery of the optical unit ≤ 35degrees. Temperature of environment ≤ 28degrees.) block 7
 Exd60  Temperature of the radiator > 55degrees
(Temperature at the periphery of the optical unit > 35degrees. Temperature of environment > 28degrees.) block 0
 Exd61  Temperature of the radiator > 55degrees
(Temperature at the periphery of the optical unit > 35degrees. Temperature of environment > 28degrees.) block 1
 Exd62  Temperature of the radiator > 55degrees
(Temperature at the periphery of the optical unit > 35degrees. Temperature of environment > 28degrees.) block 2
 Exd63  Temperature of the radiator > 55degrees
(Temperature at the periphery of the optical unit > 35degrees. Temperature of environment > 28degrees.) block 3
 Exd64  Temperature of the radiator > 55degrees
(Temperature at the periphery of the optical unit > 35degrees. Temperature of environment > 28degrees.) block 4
 Exd65  Temperature of the radiator > 55degrees
(Temperature at the periphery of the optical unit > 35degrees. Temperature of environment > 28degrees.) block 5
 Exd66  Temperature of the radiator > 55degrees
(Temperature at the periphery of the optical unit > 35degrees. Temperature of environment > 28degrees.) block 6
 Exd67  Temperature of the radiator > 55degrees
(Temperature at the periphery of the optical unit > 35degrees. Temperature of environment > 28degrees.) block 7
 Exd68  Temperature of the radiator > 55degrees
(Temperature at the periphery of the optical unit > 35degrees. Temperature of environment ≤ 28degrees.) block 0
 Exd69  Temperature of the radiator > 55degrees
(Temperature at the periphery of the optical unit > 35degrees. Temperature of environment ≤ 28degrees.) block 1
 Exd6a  Temperature of the radiator > 55degrees
(Temperature at the periphery of the optical unit > 35degrees. Temperature of environment ≤ 28degrees.) block 2
 Exd6b  Temperature of the radiator > 55degrees
(Temperature at the periphery of the optical unit > 35degrees. Temperature of environment ≤ 28degrees.) block 3
 Exd6c  Temperature of the radiator > 55degrees
(Temperature at the periphery of the optical unit > 35degrees. Temperature of environment ≤ 28degrees.) block 4
 Exd6d  Temperature of the radiator > 55degrees
(Temperature at the periphery of the optical unit > 35degrees. Temperature of environment ≤ 28degrees.) block 5
 Exd6e  Temperature of the radiator > 55degrees
(Temperature at the periphery of the optical unit > 35degrees. Temperature of environment ≤ 28degrees.) block 6
 Exd6f  Temperature of the radiator > 55degrees
(Temperature at the periphery of the optical unit > 35degrees. Temperature of environment ≤ 28degrees.) block 7
 Exd70  Temperature of the radiator > 55degrees
(Temperature at the periphery of the optical unit ≤ 35degrees.) block 0
 Exd71  Temperature of the radiator > 55degrees
(Temperature at the periphery of the optical unit ≤ 35degrees.) block 1
 Exd72  Temperature of the radiator > 55degrees
(Temperature at the periphery of the optical unit ≤ 35degrees.) block 2
 Exd73  Temperature of the radiator > 55degrees
(Temperature at the periphery of the optical unit ≤ 35degrees.) block 3
 Exd74  Temperature of the radiator > 55degrees
(Temperature at the periphery of the optical unit ≤ 35degrees.) block 4
 Exd75  Temperature of the radiator > 55degrees
(Temperature at the periphery of the optical unit ≤ 35degrees.) block 5
 Exd76  Temperature of the radiator > 55degrees
(Temperature at the periphery of the optical unit ≤ 35degrees.) block 6
 Exd77  Temperature of the radiator > 55degrees
(Temperature at the periphery of the optical unit ≤ 35degrees.) block 7
 Exd78  Dew condensation error. block 0
 Exd79  Dew condensation error. block 1
 Exd7a  Dew condensation error. block 2
 Exd7b  Dew condensation error. block 3
 Exd7c  Dew condensation error. block 4
 Exd7d  Dew condensation error. block 5
 Exd7e  Dew condensation error. block 6
 Exd7f  Dew condensation error. block 7
 Exd80  The LD block has dew
(Temperature of the LD block < 22degrees. Temperature inside the machine ≥ 18degrees.) block 0
 Exd81  The LD block has dew
(Temperature of the LD block < 22degrees. Temperature inside the machine ≥ 18degrees.) block 1
 Exd82  The LD block has dew
(Temperature of the LD block < 22degrees. Temperature inside the machine ≥ 18degrees.) block 2
 Exd83  The LD block has dew
(Temperature of the LD block < 22degrees. Temperature inside the machine ≥ 18degrees.) block 3
 Exd84  The LD block has dew
(Temperature of the LD block < 22degrees. Temperature inside the machine ≥ 18degrees.) block 4
 Exd85  The LD block has dew
(Temperature of the LD block < 22degrees. Temperature inside the machine ≥ 18degrees.) block 5
 Exd86  The LD block has dew
(Temperature of the LD block < 22degrees. Temperature inside the machine ≥ 18degrees.) block 6
 Exd87  The LD block has dew
(Temperature of the LD block < 22degrees. Temperature inside the machine ≥ 18degrees.) block 7
 Exd88  The LD block has dew
(Temperature of the LD block < 22degrees. Temperature inside the machine < 18degrees.) block 0
 Exd89  The LD block has dew
(Temperature of the LD block < 22degrees. Temperature inside the machine < 18degrees.) block 1
 Exd8a  The LD block has dew
(Temperature of the LD block < 22degrees. Temperature inside the machine < 18degrees.) block 2
 Exd8b  The LD block has dew
(Temperature of the LD block < 22degrees. Temperature inside the machine < 18degrees.) block 3
 Exd8c  The LD block has dew
(Temperature of the LD block < 22degrees. Temperature inside the machine < 18degrees.) block 4
 Exd8d  The LD block has dew
(Temperature of the LD block < 22degrees. Temperature inside the machine < 18degrees.) block 5
 Exd8e  The LD block has dew
(Temperature of the LD block < 22degrees. Temperature inside the machine < 18degrees.) block 6
 Exd8f  The LD block has dew
(Temperature of the LD block < 22degrees. Temperature inside the machine < 18degrees.) block 7
 Exd90  Temperature of the LD block < 5degrees
(Temperature at the periphery of the optical unit ≥ 17degrees.) block 0
 Exd91  Temperature of the LD block < 5degrees
(Temperature at the periphery of the optical unit ≥ 17degrees.) block 1
 Exd92  Temperature of the LD block < 5degrees
(Temperature at the periphery of the optical unit ≥ 17degrees.) block 2
 Exd93  Temperature of the LD block < 5degrees
(Temperature at the periphery of the optical unit ≥ 17degrees.) block 3
 Exd94  Temperature of the LD block < 5degrees
(Temperature at the periphery of the optical unit ≥ 17degrees.) block 4
 Exd95  Temperature of the LD block < 5degrees
(Temperature at the periphery of the optical unit ≥ 17degrees.) block 5
 Exd96  Temperature of the LD block < 5degrees
(Temperature at the periphery of the optical unit ≥ 17degrees.) block 6
 Exd97  Temperature of the LD block < 5degrees
(Temperature at the periphery of the optical unit ≥ 17degrees.) block 7
 Exd98  Temperature of the LD block < 5degrees
(Temperature at the periphery of the optical unit < 17degrees. Temperature of environment ≥ 18degrees.) block 0
 Exd99  Temperature of the LD block < 5degrees
(Temperature at the periphery of the optical unit < 17degrees. Temperature of environment ≥ 18degrees.) block 1
 Exd9a  Temperature of the LD block < 5degrees
(Temperature at the periphery of the optical unit < 17degrees. Temperature of environment ≥ 18degrees.) block 2
 Exd9b  Temperature of the LD block < 5degrees
(Temperature at the periphery of the optical unit < 17degrees. Temperature of environment ≥ 18degrees.) block 3
 Exd9c  Temperature of the LD block < 5degrees
(Temperature at the periphery of the optical unit < 17degrees. Temperature of environment ≥ 18degrees.) block 4
 Exd9d  Temperature of the LD block < 5degrees
(Temperature at the periphery of the optical unit < 17degrees. Temperature of environment ≥ 18degrees.) block 5
 Exd9e  Temperature of the LD block < 5degrees
(Temperature at the periphery of the optical unit < 17degrees. Temperature of environment ≥ 18degrees.) block 6
 Exd9f  Temperature of the LD block < 5degrees
(Temperature at the periphery of the optical unit < 17degrees. Temperature of environment ≥ 18degrees.) block 7
 Exda0  Temperature of the LD block < 5degrees
(Temperature at the periphery of the optical unit < 17degrees. Temperature of environment < 18degrees.) block 0
 Exda1  Temperature of the LD block < 5degrees
(Temperature at the periphery of the optical unit < 17degrees. Temperature of environment < 18degrees.) block 1
 Exda2  Temperature of the LD block < 5degrees
(Temperature at the periphery of the optical unit < 17degrees. Temperature of environment < 18degrees.) block 2
 Exda3  Temperature of the LD block < 5degrees
(Temperature at the periphery of the optical unit < 17degrees. Temperature of environment < 18degrees.) block 3
 Exda4  Temperature of the LD block < 5degrees
(Temperature at the periphery of the optical unit < 17degrees. Temperature of environment < 18degrees.) block 4
 Exda5  Temperature of the LD block < 5degrees
(Temperature at the periphery of the optical unit < 17degrees. Temperature of environment < 18degrees.) block 5
 Exda6  Temperature of the LD block < 5degrees
(Temperature at the periphery of the optical unit < 17degrees. Temperature of environment < 18degrees.) block 6
 Exda7  Temperature of the LD block < 5degrees
(Temperature at the periphery of the optical unit < 17degrees. Temperature of environment < 18degrees.) block 7
 Exdb0  LD block can not cool. block 0
 Exdb1  LD block can not cool. block 1
 Exdb2  LD block can not cool. block 2
 Exdb3  LD block can not cool. block 3
 Exdb4  LD block can not cool. block 4
 Exdb5  LD block can not cool. block 5
 Exdb6  LD block can not cool. block 6
 Exdb7  LD block can not cool. block 7
 Exdb8  LD block can not cool. block 0
 Exdb9  LD block can not cool. block 1
 Exdba  LD block can not cool. block 2
 Exdbb  LD block can not cool. block 3
 Exdbc  LD block can not cool. block 4
 Exdbd  LD block can not cool. block 5
 Exdbe  LD block can not cool. block 6
 Exdbf  LD block can not cool. block 7
 Exdc0  Irregular peltier. block 0
 Exdc1  Irregular peltier. block 1
 Exdc2  Irregular peltier. block 2
 Exdc3  Irregular peltier. block 3
 Exdc4  Irregular peltier. block 4
 Exdc5  Irregular peltier. block 5
 Exdc6  Irregular peltier. block 6
 Exdc7  Irregular peltier. block 7
 Exdd0  TP1-TP3 peltier line is incorrect
 Exdd1  TP1-TP5 peltier line is incorrect
 Exdd2  TP1-TP7 peltier line is incorrect
 Exdd3  TP3-TP5 peltier line is incorrect
 Exdd4  TP3-TP7 peltier line is incorrect
 Exdd5  TP5-TP7 peltier line is incorrect
 Exdd6  TP2-TP4 peltier line is incorrect
 Exdd7  TP2-TP6 peltier line is incorrect
 Exdd8  TP2-TP8 peltier line is incorrect
 Exdd9  TP4-TP6 peltier line is incorrect
 Exdda  TP4-TP8 peltier line is incorrect
 Exddb  TP6-TP8 peltier line is incorrect
 Exe01  Excessive current in the LD drive (driver 1 board)
 Exe02  Excessive current in the LD drive (driver 2 board)
 Exe03  Excessive current in the LD drive (driver 3 board)
 Exe04  Excessive current in the LD drive (driver 4 board)
 Exe05  Driver board temperature error or FPGA Version error
 Exe06  -5 V power supply error
 Exe07  Calibration sensor is not connected
 Exe08  Offset error in the calibration sensor
 Exe09  Irregular 5 V power supply
 Exe0a  Irregular +15 V power supply
 Exe0b  Irregular -15 V power supply
 Exe0c  Irregular 24 V power supply
 Exe0d  Cover switch is OFF
 Exe0e  BL command error (counter value is 0)
 Exe0f  Zoom sensor does not detect
 Exe10  Focus sensor does not detect
 Exe11  Time over for home return.(zoom or focus motor)
 Exe12  Power supply irregular while the motor is driving.(zoom or focus motor)
 Exe13  [8600 ]Pulse motor has traveled beyond the away limit. (zoom or focus motor)
 Exe13  [8000-2]Pulse motor has traveled beyond the limit. (zoom or focus motor)
 Exe14  [8600 ]Pulse motor has traveled beyond the home limit. (zoom or focus motor)
 Exe14  [8600-2]Irregular power supply(instantaneous loss)
 Exe20  Temperature of the LD block is high
 Exe21  Temperature at the periphery of the optical unit is high
 Exe22  Temperature of the radiating fin of the Peltier element is high
 Exe23  Dew condensation error
 Exe24  Sensor for LD block has not been connected
 Exe25  Sensor for the periphery of the optical unit has not been connected
 Exe26  Sensor for the radiating fin of the Peltier element has not been connected
 Exe27  Sensor for the dew condensation detection sensor has not been connected
 Exe28  Temperature of the LD block is low
 Exe30  Power supply error occurred when the recording head received the DW command
 Exe31  Command error occurred when the recording head received the DW command
 Exe32  Download error occurred when the recording head received the DP command
 Exe33  Download error occurred when the recording head received the DF command
 Exe34  Download address error occurred
 Exe35  Error occurred when the recording head received the BU command
 Exe36  Error occurred when the recording head received the BD command
 Exe40  Writing error occurred when the recording head received the AC command
 Exe41  Writing error on EEPROM
 Exe42  RAM error
 Exe43  ROM check sum error
 Exe44  FPGA error
 Exe45  Data error due to a divide-by-zero error
 Exe60  LD Current setting error
 Exe61  Temperature of the LD block > 28degrees
(Temperature at the periphery of the optical unit > 35degrees. Temperature environment ≤ 28degrees)
 Exe62  Temperature of the LD block > 28degrees
(Temperature at the periphery of the optical unit ≤ 35degrees. Temperature of environment > 28degrees)
 Exe63  Temperature of the LD block > 28degrees
(Temperature at the periphery of the optical unit ≤ 35degrees. Temperature of environment ≤ 28degrees)
 Exe64  Temperature at the periphery of the optical unit > 35degrees
(Temperature of environment ≤ 28degrees)
 Exe65  Temperature of the radiator > 55degrees
(Temperature at the periphery of the optical unit > 35degrees. Temperature of environment ≤ 28degrees)
 Exe66  Temperature of the radiator > 55degrees
(Temperature at the periphery of the optical unit ≤ 35degrees)
 Exe67  The LD block has dew
(Temperature of the LD block < 22degrees. Temperature inside the machine ≥ 18degrees)
 Exe68  The LD block has dew
(Temperature of the LD block < 22degrees. Temperature inside the machine < 18degrees)
 Exe69  Temperature of the LD block < 5degrees
(Temperature at the periphery of the optical unit ≥ 17degrees)
 Exe6a  Temperature of the LD block < 5degrees
(Temperature at the periphery of the optical unit < 17degrees. Temperature of environment ≥ 18degrees)
 Exe6b  Temperature of the LD block > 28degrees
(Temperature at the periphery of the optical unit > 35degrees. Temperature of environment ≤ 28degrees)
 Exe6c  Temperature of the LD block > 28degrees
(Temperature at the periphery of the optical unit ≤ 35degrees. Temperature of environment > 28degrees)
 Exe6d  Temperature of the LD block > 28degrees
(Temperature at the periphery of the optical unit ≤ 35degrees. Temperature of environment ≤ 28degrees)
 Exe6e  Temperature at the periphery of the optical unit > 35degrees
(Temperature of environment ≤ 28degrees)
 Exe6f  Temperature of the radiator > 55degrees
(Temperature at the periphery of the optical unit > 35degrees. Temperature of environment ≤ 28degrees)
 Exe70  Temperature of the radiator > 55degrees
(Temperature at the periphery of the optical unit ≤ 35degrees)
 Exe71  It is just before an exposure head has dew
(Temperature of the LD block < 22degrees. Temperature of environment ≥ 18 degrees)
 Exe72  It is just before an exposure head has dew
(Temperature of the LD block < 22degrees. Temperature of environment < 18 degrees)
 Exe73  5degrees ≤ Temperature of the LD block < 17degrees
(Temperature of environment ≥ 18degrees)
 Exe74  5degrees ≤ Temperature of the LD block < 17degrees
(Temperature of environment < 18degrees)
 Exea0  Light intensity adjustment error 0ch
 Exea1  Light intensity adjustment error 1ch
 Exea2  Light intensity adjustment error 2ch
 Exea3  Light intensity adjustment error 3ch
 Exea4  Light intensity adjustment error 4ch
 Exea5  Light intensity adjustment error 5ch
 Exea6  Light intensity adjustment error 6ch
 Exea7  Light intensity adjustment error 7ch
 Exea8  Light intensity adjustment error 8ch
 Exea9  Light intensity adjustment error 9ch
 Exeaa  Light intensity adjustment error 10ch
 Exeab  Light intensity adjustment error 11ch
 Exeac  Light intensity adjustment error 12ch
 Exead  Light intensity adjustment error 13ch
 Exeae  Light intensity adjustment error 14ch
 Exeaf  Light intensity adjustment error 15ch
 Exeb0  Light intensity adjustment error 16ch
 Exeb1  Light intensity adjustment error 17ch
 Exeb2  Light intensity adjustment error 18ch
 Exeb3  Light intensity adjustment error 19ch
 Exeb4  Light intensity adjustment error 20ch
 Exeb5  Light intensity adjustment error 21ch
 Exeb6  Light intensity adjustment error 22ch
 Exeb7  Light intensity adjustment error 23ch
 Exeb8  Light intensity adjustment error 24ch
 Exeb9  Light intensity adjustment error 25ch
 Exeba  Light intensity adjustment error 26ch
 Exebb  Light intensity adjustment error 27ch
 Exebc  Light intensity adjustment error 28ch
 Exebd  Light intensity adjustment error 29ch
 Exebe  Light intensity adjustment error 30ch
 Exebf  Light intensity adjustment error 31ch
 Exec0 Light intensity adjustment error 32ch
 Exec1  Light intensity adjustment error 33ch
 Exec2  Light intensity adjustment error 34ch
 Exec3  Light intensity adjustment error 35ch
 Exec4  Light intensity adjustment error 36ch
 Exec5  Light intensity adjustment error 37ch
 Exec6  Light intensity adjustment error 38ch
 Exec7  Light intensity adjustment error 39ch
 Exec8  Light intensity adjustment error 40ch
 Exec9  Light intensity adjustment error 41ch
 Execa  Light intensity adjustment error 42ch
 Execb  Light intensity adjustment error 43ch
 Execc  Light intensity adjustment error 44ch
 Execd  Light intensity adjustment error 45ch
 Exece  Light intensity adjustment error 46ch
 Execf  Light intensity adjustment error 47ch
 Exed0  Light intensity adjustment error 48ch
 Exed1  Light intensity adjustment error 49ch
 Exed2  Light intensity adjustment error 50ch
 Exed3  Light intensity adjustment error 51ch
 Exed4  Light intensity adjustment error 52ch
 Exed5  Light intensity adjustment error 53ch
 Exed6  Light intensity adjustment error 54ch
 Exed7  Light intensity adjustment error 55ch
 Exed8  Light intensity adjustment error 56ch
 Exed9  Light intensity adjustment error 57ch
 Exeda  Light intensity adjustment error 58ch
 Exedb  Light intensity adjustment error 59ch
 Exedc  Light intensity adjustment error 60ch
 Exedd  Light intensity adjustment error 61ch
 Exede  Light intensity adjustment error 62ch
 Exedf  Light intensity adjustment error 63ch
 Exee0  Incorrect command has been input
 Exee1  Temperature of the LD block > 28degrees
(Temperature at the periphery of the optical unit > 35degrees. Temperature of environment > 28degrees)
 Exee2  Temperature at the periphery of the optical unit > 35degrees
(Temperature of environment > 28degrees)
 Exee3  Temperature of the radiator > 55degrees
(Temperature at the periphery of the optical unit > 35degrees. Temperature of environment > 28degrees)
 Exee4  It is just before an exposure head has dew
(Temperature of the LD block ≥ 22degrees.)
 Exee5  Temperature of the LD block < 5degrees
(Temperature at the periphery of the optical unit < 17degrees. Temperature of environment < 18degrees.)
 Exef0  Recording head processing task is now processing another message
 Exef2  Recording head unit is not running
 Exef3  Check sum error occurred when data was uploaded
 Exef4  Address error occurred when data was uploaded
 Exef5  LD calibration can not processed because temperature of LD block is too low
 Exef6  A command was sent to the exposure head. But, no answer was returned from the exposure head
 Exfa0  System error (stack overflow)
 Exfa1  Floating point arithmetic error
 Exfa2  Divide-by-zero error
 Exfa3  System error (semaphore)
 Exfb0  Flash memory erase error
 Exfb1  Flash memory erase error (during verification)
 Exfb2  Flash memory write error
 Exfb3  Incompatible flash memory