07814 652568 steve@rsprepress.com

Linotronic 530

Boot Status Messages
 Code:                                               Description:
 INIT RECORDER START    Recorder initialization started
 INIT RECORDER 0    Time loop of about 45s. (LES power on delay)
 INIT RECORDER 1    Polygon drive initialized using the last X resolution setting
 INIT RECORDER 2    Film feed initialized using the last Y resolution value
 INIT RECORDER 3    Current density set
 INIT RECORDER 4    Cutter initialization, move to cutter stop, if necessary
 INIT RECORDER DONE
 Recorder is ready
   Recorder initialization completed successfully
 (In Test mode, not all initialization routines are executed; certain
 errors may not be recognized)

 

Status Messages During Operation
 Message:                                      Description:
 LI5 ENABLE    LI5 interface enabled; parameters can be defined also from
 the LT55 panel (equal priority)
 PROCESS ACTIVE    A process is active; no other process can be started. The
 process may be aborted by (SHIFT) STOP
 USER STOPPED    Process aborted by the user
 FILM ADVANCING    Film is being advanced
 FILM ADVANCE DONE    Film advance completed
 FILM CUTTING    Film is being cut
 FILM CUT DONE    Film cutting completed
 INSERT FILM    Insert film into the film transport system. Wait until the
 message is displayed
 ADJUST FILM     Adjust the film. Unlock the film drive (right-hand red button)
 Centre the film. Lock the film drive
 FILM LOADING    Film is being loaded into the film transport system
 CONTINUE FILM LOAD    Film loading is continued. Film advance with film cut
 FILM LOAD DONE     Film loading completed. Insert take-up cassette
 ALREADY FILM    Film already loaded
 ABORT FILM LOAD    Film loading aborted. Photomaterial was not recognized
 FILM UNLOADING    Film unloading is started
 FILM UNLOAD DONE    Film unloaded from the film transport system
 CUT BEFORE UNLOAD    Film loading aborted. Cut material
 NO FILM SUPPLY    No film available in film transport system (end of film)
 WARNING END OF FILM    End of film approaching alert
 FILMLOAD > CMD-
 ERROR
   Photomaterial error. (Try REC 1)
 IMAGING    Output in progress
 IMAGING DONE    Output completed
 IMAGING DONE    Recorder test printout in progress
 TEST IMAGING DONE    Recorder test printout completed
 DENSITY JOB STARTED    Density test printout in progress (several densities)
 DENSITY JOB DONE    Density test printout completed
 ACTUAL JDNS
 STARTED
   Density test printout in progress (current density only)
 ACTUAL JDNS
 STARTED
   Density test printout completed
 CHANGE TAKEUP CASS    Change the take-up cassette
 NO TAKEUP CASSETTE    Take-up cassette not inserted
 TAKEUP CASS FULL    Take-up cassette is full; material is cut automatically
 REMOVE TAKEUP
 CASS
   Remove the take-up cassette – cut has been performed
 CHECK CUTTER POS    Cutter not at stop position. Do not close the film transport
 system to avoid damaging the cutter
 WARNING DENSITY    The selected density is too low. SOL detection may not be
 possible 
 TAKO ACTIVE    Calculation of tacho correction
 WARNING TAKO    Polygon tacho correction not successful
 WARNING FILM DRIVE    Zero mark of the film transport roller not found
 RANGE OVERFLOW    Zero mark of the film transport roller not found
 X.LM + X.M > F.WIDTH    Left margin plus measure greater than film width
 NO VALID RESOLUTION    The defined resolution is not supported
 NO RES FOR LI2 STNG    The defined resolution is not allowed with the current LI2
 Parameters. Select 16 MHz async mode in the INTERFACE
 menu; the RIP must also support the 16 MHz mode 
 OLP FORCED CUT    Forced cut of material is being executed because the
 maximum  galley length of the online processor is reached
 OLP AUTOMATIC CUT    Auto film cut for online processor is being executed
 Status Error Messages
 Message:                                               Description:
 RIP, NOT CONNECTED    A backend defined as imagesetter cannot see the RIP
 RIP > NOT SELECTED    RIP and recorder not synchronized
 RECORDER > TIME OUT    START signal did not trigger an interrupt. No light at SOL?
 RECORDER > TIME OUT    SOL missing. SOL-threshold, but no SOL recognized. Light intensity too low?
 SOL amplifier failure 
 NO LIGHT > DENSITY    Selected density too low. SOL is not recognized. Increase the density 
 SPINNER > TIME OUT    Selected density too low. SOL is not recognized. Increase the 
 DENSITY >TIME OUT    At present not used
 ERROR TAKO > WRITE    Tachometer correction error on writing the correction values.
 Has been Polygon fault
 ERROR TAKO >READ    Tacho correction error on reading the correction values
 TAKO ACTIVE    Tachometer correction iteration. Please wait
 ERROR > CUT [120]    Cutter not at stop position. Limit switch still active
 ERROR > CUT [121]    Cutter time-out. Cutter blocked
 ERROR > CUT [122]    Film advance in progress. Cutting not allowed
 ERROR > FILM LOAD    Film loading error
 OLP NOT OPERABLE    Online processor not available. Check connection
 OLP NOT READY    Online processor not ready. Check online processor
 OLP BRIDGE    Failure of bridge to online processor
 LI2 >SENDER NOT OPR    LI2 sender not operable. SOPR deactivated
 LI2 >SCAN OVERRUN    Too many pixels in transferred scan line
 LI2 >SENDER ERROR    Recorder aborted the job at the receiver operable signal (ROPR). A new output request
 is issued but the old sender page signal (SPGE) of the sender is still active 
 LI2 >TIME OUT    Abort of an LI2 connection to the recorder by time-out. This error may, at present,
 not occur because a time-out is not defined
 LI2 WITHOUT LI5    Output is not controlled via the LI5 interface. Output is started by pressing the START
 key
 LI5 >NO PARTNER    LI5 partner (RIP) not available
 LI5 >TIME OUT    Time-out on the LI5 interface. This error may at present not occur because a time-out
 is not defined 
 LI5 >OVERRUN    DUART overrun on the LI5 interface. LI5 interface may not be served by the recorder 
 LI5 >PARITY ERR    Parity error on the LI5 interface
 LI5 >FRAMING ERR    Framing error on the LI5 interface
 LI5 >SYNCHR ERR    Software synchronization error on the LI5 interface
 HARD-REV TOO LARGE    Hardware revision number too large for firmware
 HARD-REV TOO SMALL    Hardware revision number too small for firmware
 HARD-REV TOO SMALL    Wrong flag returned by application process
 PLEASE RESET    Press both Reset keys
 

EEPROM Errors
 Message:                                               Description:
 EEPROM >INIT    EEPROM initialization. Default values are assumed
 EEPROM >INIT    EEPROM update. After installation of a new program on the REC1 board the EEPROM
 data has been defaulted
 EEPROM >NEW INIT    A new EEPROM was installed. Default values assumed
 EEPROM ERROR    General EEPROM error
 EEPROM >CHECKSUM    Wrong checksum of EEPROM data
 EEPROM OVERFLOW    EEPROM full. (All three EEPROM blocks were used and may no longer be written)
 Install new EEPROM
 EEPROM >OLDSOFTWARE    Firmware older than EEPROM data structure. Install new firmware
 EEPROM >OLD EEPROM    EEPROM data structure obsolete. The firmware automatically converts the data
 structure. Check the data
 EEPROM>TOO OLD    EEPROM structure very obsolete. The firmware automatically converts the data
 structure. Check the data
 EEPROM>TOO OLD    EEPROM defect. Replace the EEPROM
 NVRAM Errors
 Message:                                               Description:
 NVRAM >TOO OLD    NVRAM data structure obsolete. Reinitialze the LT55
 NVRAM >OLDSOFTWARE    Firmware older than NVRAM data . Install new firmware
 NVRAM >FATALERROR    Fatal NVRAM error; initialize the LT55 panel
 NVRAM >ERROR    General NVRAM error, initialize LT55
 NVRAM >MESSAGE ERR    General NVRAM error, initialize LT55
 

Linotronic 330

 Boot Status Messages
 Code:                                               Description:
 INIT RECORDER START    Recorder initialization started
 INIT RECORDER 0    Time loop of about 45s. (LES power on delay)
 INIT RECORDER 1    Polygon drive initialized using the last X resolution setting
 INIT RECORDER 2    Film feed initialized using the last Y resolution value
 INIT RECORDER 3    Current density set
 INIT RECORDER 4    Cutter initialization, move to cutter stop, if necessary
 INIT RECORDER DONE
 Recorder is ready
   Recorder initialization completed successfully
 (In Test mode, not all initialization routines are executed; certain
 errors may not be recognized)

 

 Status Messages During Operation
 Message:                                       Description:
 LI5 ENABLE    LI5 interface enabled; parameters can be defined also from
 the LT55 panel (equal priority)
 PROCESS ACTIVE    A process is active; no other process can be started. The
 process may be aborted by (SHIFT) STOP
 USER STOPPED    Process aborted by the user
 FILM ADVANCING    Film is being advanced
 FILM ADVANCE DONE    Film advance completed
 FILM CUTTING    Film is being cut
 FILM CUT DONE    Film cutting completed
 INSERT FILM    Insert film into the film transport system. Wait until the
 message is displayed
 ADJUST FILM     Adjust the film. Unlock the film drive (right-hand red button)
 Centre the film. Lock the film drive
 FILM LOADING    Film is being loaded into the film transport system
 CONTINUE FILM LOAD    Film loading is continued. Film advance with film cut
 FILM LOAD DONE     Film loading completed. Insert take-up cassette
 ALREADY FILM    Film already loaded
 ABORT FILM LOAD    Film loading aborted. Photomaterial was not recognized
 FILM UNLOADING    Film unloading is started
 FILM UNLOAD DONE    Film unloaded from the film transport system
 CUT BEFORE UNLOAD    Film loading aborted. Cut material
 NO FILM SUPPLY    No film available in film transport system (end of film)
 WARNING END OF FILM    End of film approaching alert
 FILMLOAD > CMD-
 ERROR
   Photomaterial error. (Try REC 1)
 IMAGING    Output in progress
 IMAGING DONE    Output completed
 IMAGING DONE    Recorder test printout in progress
 TEST IMAGING DONE    Recorder test printout completed
 DENSITY JOB STARTED    Density test printout in progress (several densities)
 DENSITY JOB DONE    Density test printout completed
 ACTUAL JDNS
 STARTED
   Density test printout in progress (current density only)
 ACTUAL JDNS
 STARTED
   Density test printout completed
 CHANGE TAKEUP CASS    Change the take-up cassette
 NO TAKEUP CASSETTE    Take-up cassette not inserted
 TAKEUP CASS FULL    Take-up cassette is full; material is cut automatically
 REMOVE TAKEUP
 CASS
   Remove the take-up cassette – cut has been performed
 CHECK CUTTER POS    Cutter not at stop position. Do not close the film transport
 system to avoid damaging the cutter
 WARNING DENSITY    The selected density is too low. SOL detection may not be
 possible 
 TAKO ACTIVE    Calculation of tacho correction
 WARNING TAKO    Polygon tacho correction not successful
 WARNING FILM DRIVE    Zero mark of the film transport roller not found
 RANGE OVERFLOW    Zero mark of the film transport roller not found
 X.LM + X.M > F.WIDTH    Left margin plus measure greater than film width
 NO VALID RESOLUTION    The defined resolution is not supported
 NO RES FOR LI2 STNG    The defined resolution is not allowed with the current LI2
 Parameters. Select 16 MHz async mode in the INTERFACE
 menu; the RIP must also support the 16 MHz mode 
 OLP FORCED CUT    Forced cut of material is being executed because the
 maximum  galley length of the online processor is reached
 OLP AUTOMATIC CUT    Auto film cut for online processor is being executed
 Status Error Messages
 Message:                                               Description:
 RIP, NOT CONNECTED    A backend defined as imagesetter cannot see the RIP
 RIP > NOT SELECTED    RIP and recorder not synchronized
 RECORDER > TIME OUT    START signal did not trigger an interrupt. No light at SOL?
 RECORDER > TIME OUT    SOL missing. SOL-threshold, but no SOL recognized. Light intensity too low?
 SOL amplifier failure 
 NO LIGHT > DENSITY    Selected density too low. SOL is not recognized. Increase the density 
 SPINNER > TIME OUT    Selected density too low. SOL is not recognized. Increase the 
 DENSITY >TIME OUT    At present not used
 ERROR TAKO > WRITE    Tachometer correction error on writing the correction values.
 Has been Polygon fault
 ERROR TAKO >READ    Tacho correction error on reading the correction values
 TAKO ACTIVE    Tachometer correction iteration. Please wait
 ERROR > CUT [120]    Cutter not at stop position. Limit switch still active
 ERROR > CUT [121]    Cutter time-out. Cutter blocked
 ERROR > CUT [122]    Film advance in progress. Cutting not allowed
 ERROR > FILM LOAD    Film loading error
 OLP NOT OPERABLE    Online processor not available. Check connection
 OLP NOT READY    Online processor not ready. Check online processor
 OLP BRIDGE    Failure of bridge to online processor
 LI2 >SENDER NOT OPR    LI2 sender not operable. SOPR deactivated
 LI2 >SCAN OVERRUN    Too many pixels in transferred scan line
 LI2 >SENDER ERROR    Recorder aborted the job at the receiver operable signal (ROPR). A new output request
 is issued but the old sender page signal (SPGE) of the sender is still active 
 LI2 >TIME OUT    Abort of an LI2 connection to the recorder by time-out. This error may, at present,
 not occur because a time-out is not defined
 LI2 WITHOUT LI5    Output is not controlled via the LI5 interface. Output is started by pressing the START
 key
 LI5 >NO PARTNER    LI5 partner (RIP) not available
 LI5 >TIME OUT    Time-out on the LI5 interface. This error may at present not occur because a time-out
 is not defined 
 LI5 >OVERRUN    DUART overrun on the LI5 interface. LI5 interface may not be served by the recorder 
 LI5 >PARITY ERR    Parity error on the LI5 interface
 LI5 >FRAMING ERR    Framing error on the LI5 interface
 LI5 >SYNCHR ERR    Software synchronization error on the LI5 interface
 HARD-REV TOO LARGE    Hardware revision number too large for firmware
 HARD-REV TOO SMALL    Hardware revision number too small for firmware
 HARD-REV TOO SMALL    Wrong flag returned by application process
 PLEASE RESET    Press both Reset keys
 

EEPROM Errors
 Message:                                               Description:
 EEPROM >INIT    EEPROM initialization. Default values are assumed
 EEPROM >INIT    EEPROM update. After installation of a new program on the REC1 board the EEPROM
 data has been defaulted
 EEPROM >NEW INIT    A new EEPROM was installed. Default values assumed
 EEPROM ERROR    General EEPROM error
 EEPROM >CHECKSUM    Wrong checksum of EEPROM data
 EEPROM OVERFLOW    EEPROM full. (All three EEPROM blocks were used and may no longer be written)
 Install new EEPROM
 EEPROM >OLDSOFTWARE    Firmware older than EEPROM data structure. Install new firmware
 EEPROM >OLD EEPROM    EEPROM data structure obsolete. The firmware automatically converts the data
 structure. Check the data
 EEPROM>TOO OLD    EEPROM structure very obsolete. The firmware automatically converts the data
 structure. Check the data
 EEPROM>TOO OLD    EEPROM defect. Replace the EEPROM
 NVRAM Errors
 Message:                                               Description:
 NVRAM >TOO OLD    NVRAM data structure obsolete. Reinitialze the LT55
 NVRAM >OLDSOFTWARE    Firmware older than NVRAM data . Install new firmware
 NVRAM >FATALERROR    Fatal NVRAM error; initialize the LT55 panel
 NVRAM >ERROR    General NVRAM error, initialize LT55
 NVRAM >MESSAGE ERR    General NVRAM error, initialize LT55

Linotronic 300R

 Boot Status Messages
 Code:                 Description:
 200    Selftest 0 
 201    Selftest 1
 202    Selftest 2
 203    Selftest 3
 204    Selftest 4
 205    Selftest 5 
 206    Selftest 6
 207    Selftest 7
 208    Selftest 8
 210    Selftest done

 

 
 Recorder Messages
 Error Code:      Description:
 001    Film End
 002    No take up cassette
 003    Take up cassette full
 004    Caution: Tako malfunction
 005    Cutter not home
 006    Density malfunction
 007    OLP-FLAG too long
 010    Exposure active
 011    Exposure ready
 012    Exposure stopped
 013    Test exposure ready
 014    Text exposure ready
 020    Film load active
 021    Film load ready
 022    Take up cassette fitted
 023    Insert film
 024    Adjust film
 025    Film in transport
 026    Film load stopped
 030    Film unload active
 031    Film unload active
 032    Take up casette is fitted
 040    Film advance active
 041    Film advance ready
 050    Cut active
 051    Cut ready
 052    Cut stopped
 100    Caution: Polygon error
 101    Abort: Fine density error
 102    Abort: Coarse density error
 103    Abort: Density adjust
 104    Film start / stop. No start
 105    Film start / stop inactive
 110    Abort: Fatal error BELI
 111    Abort: Command error
 112    Abort: Data error BELI
 113    Abort: X/Y error
 116    Abort: Machine parameter
 120    Abort: Film load command error
 121    Abort: Film shutter does not close
 122    Abort: Film Tension
 141    Abort: Film unload command error
 150    Abort: Cutter does not move
 151    Abort: Cutter is blocked
 160    Abort: No input processor Clk
 161    Abort: No output process Clk
 162    Abort: Input window counter
 163    Abort: Output window counter
 164    Abort: Altern buffer A counter
 165    Abort: Altern buffer A data
 166    Abort: Altern buffer B counter
 167    Abort: Altern buffer B data
 180    Abort: Bus error
 181    Abort: Address error
 182    Abort: Ilegal instruction
 183    Abort: Zero divide
 184    Abort: CHK instruction
 185    Abort: TRAPV instruction
 186    Abort: Privilege violation
 187    Abort: Trace
 188    Abort: Reserved
 189    Abort: Trap
 190    Abort: Auto vector interrupt
 191    Abort: Hardware vector interupt
 215    Message: Adjust active
 216    Message: Adjust ready
 217    Message: Exposure active
 218    Message: Exposure ready
 219    Message: Density adjust active
 220    Message: Density adjust ready
 221    Message: Tako adjust active
 222    Message: Tako adjust ready
 233    O.L.P. error. No take up cassette
 235    Sender not active
 236    SOPR inactive
 237    SSCN exceeds active length
 238    Timeout LI2
 240    LI5 not available
 246    EEprom error Write
 248    EEprom error Data
 252    EEprom error Block
 254    NV ram error (LT50)
 

Heidelberg Herkules

Error Index:
 0000-9FFF: Errors    0000-00FF: reserve
     0100-08FF: boot system
     0800-0FFF: main control
     1000-1FFF: communication control
     2000-2FFF: video control
     3000-3FFF: Material control
     4000-4FFF: feed control
     5000-5FFF: user interface
     6000-6FFF: machine drivers
     7000-77FF: operating system PSOS-Fehler
     7800-7BFF: file system
     7C00-7DFF: laser control HELIOS
     7E00-7FFF: peeler control HELIOS
     8000-87FF: ecc control
     8800-9FFF: reserve (free)
 A000-BFFF: Warnings    A000-A1FF: boot system
     A200-A3FF: main control
     A400-A5FF: communication control
     A600-A7FF: video control
     A800-A9FF: Material control
     AA00-ABFF: feed control
     AC00-ADFF: user interface
     AE00-AFFF: machine driver
     B000-B1FF: operation system PSOS+
     B200-B3FF: file system
     B400-B5FF: ecc control
     B600-BFFF: reserve (free)
 C000-DFFF: User Info    C000-C3FF: user intervention for STA
     C400-C7FF: user intervention for ORL
     C800-CBFF: user intervention for SWE
     CC00-CFFF: user intervention for HAU
     C400-C7FF: user intervention for ORL
     D400-DFFF: reserve (free)
 E000-FFFE: reserve    
 FFFF: special used    FFFF     : special used by HERKULES
 
Error:                                     Description:
 USER INFO 0000    Recorder is ready for operating
 ERROR 0001    Recorder in test run – No exposure possible
 ERROR 0800    Recorder hardware defective
 ERROR 0801    The inserted diskette is not the system diskette for this recorder
 ERROR 0802    The graphics display could not be initialized
 ERROR 0803    The material reception unit (collecting cassette or on-line device connected) has not been selected
 ERROR 0804    Supply cassette not inserted
 ERROR 0805    Collecting cassette not inserted
 ERROR 0806    Material feed error
 ERROR 0807    Collecting cassette has not been emptied
 ERROR 0808    Material feed into the material reception unit (collecting cassette or connected on-line device) not  possible 
 ERROR 0809    An error occurred in the recorder cutting device
 ERROR 080A    Supply cassette is empty
 ERROR 080D    Internal error
 ERROR 080E    An error occurred during the automatic material position and width recognition
 ERROR 080F    The on-line processor is not switched on
 ERROR 0810    On-line processor not ready
 ERROR 0811    The on-line processor is not connected to the on-line recorder interface
 ERROR 0812    Power supply error – An error occurred in the negative 12 Volt power supply;
 ERROR 0813    Power supply error – An error occurred in the positive 12 Volt power supply
 ERROR 0814    Power supply error – An error occurred in the negative 15 Volt power supply
 ERROR 0815    Power supply error – An error occurred in the positive 15 Volt power supply
 ERROR 0816    Power supply error – An error occurred in the first negative 2 Volt power supply
 ERROR 0817    Power supply error – An error occurred in the negative 5.2 Volt power supply
 ERROR 0818    Power supply error – An error occurred in the positive 7.5 Volt power supply
 ERROR 0819    Power supply error – An error occurred in the positive 24 Volt power supply
 ERROR 081A    Power supply error – An error occurred in the second negative 2 Volt power supply
 ERROR 081B    Power supply error – An error occurred in the positive 28 Volt power supply
 ERROR 081C    Power supply error – An error occurred in one of the power supply modules
 ERROR 081D    The recorder could not be initialized
 ERROR 081F    The supply cassette does not belong to this recorder
 ERROR 0900    The communication with the laser unit is interrupted
 ERROR 1001    No more memory available to create a SPEEDWAY message
 ERROR 2000    The recorder hardware could not be reset
 ERROR 2001    The recorder hardware could not be initialized
 ERROR 2002    The recorder hardware could not be reset
 ERROR 2003    The recorder hardware could not be initialized
 ERROR 2004    The recorder hardware could not be initialized
 ERROR 2005    The recorder hardware could not be initialized
 ERROR 2007    The recorder hardware could not be initialized
 ERROR 2008    The SPEEDWAY link is interrupted
 ERROR 2009    The SPEEDWAY link is interrupted
 ERROR 200A    The SPEEDWAY link is interrupted
 ERROR 200B    The system memory for SPEEDWAY communication could not be released
 ERROR 200C    An error occurred in the program sequence
 ERROR 3101    An internal error occurred when calling up the material control
 ERROR 3102    An internal error occurred when calling up the material control
 ERROR 3103    An internal error occurred when calling up the material control
 ERROR 3104    An internal error occurred when calling up the material control
 ERROR 3105    An internal error occurred when calling up the material control
 ERROR 3106    The material feed length exceeds the maximum feed length
 ERROR 3107    The material type, which is selected in the material parameter MATERIAL_TYPE, isn’t supported by the recorder
 ERROR 3108    The material thickness (in combination with the selected material type) isn’t supported by the recorder. The thickness is selected in the material parameter MATERIAL_THICKNESS
 ERROR 3109    The measured material width (in combination with the selected material thickness and material type) isn’t supported by the recorder
 ERROR 3110    The VAR_MAT_CONTROL-parameters (PID 681-700) in the static parameters do not have the defined format or they are corrupted
 ERROR 3200    An error occurred when initializing the punch
 ERROR 3201    An error occurred when selecting the punches
 ERROR 3202    An error occurred during the punching
 ERROR 3300    An error occurred during the transport of the residual material – The supply cassette is empty
 ERROR 3301    An error occurred during the transport of the residual material – The supply cassette is empty
 ERROR 3302    An error occurred during the transport of the residual material – The supply cassette is empty
 ERROR 3400    The residual material measurement is incorrect
 ERROR 3401    The residual material measurement is incorrect
 ERROR 3402    The residual material measurement is incorrect
 ERROR 3500    An error occurred during the material transport
 ERROR 3501    An error occurred when loading the material
 ERROR 3502    An error occurred during the material transport
 ERROR 3503    An error occurred during the material transport
 ERROR 3504    An error occurred during the material transport
 ERROR 3505    An error occurred during the material transport
 ERROR 3506    An error occurred during the material transport
 ERROR 3507    An error occurred when loading the material
 ERROR 3508    An error occurred when loading the material. The end of material has been recognized
 ERROR 3509    An error occurred when loading the material. The end of material has been recognized
 ERROR 350A    An error occurred during the loading process. Material jam has occurred
 ERROR 350B    An error occurred during the loading process. Material jam has occurred
 ERROR 350C    An error occurred during the loading process. There is residual material in the recorder trough. The end of material has been recognized
 ERROR 350D    An error occurred during the unloading process
 ERROR 350F    An error occurred during the unloading process
 ERROR 3510    An error occurred during the unloading process
 ERROR 3511    An error occurred during the unloading process
 ERROR 3512    An error occurred during the unloading process
 ERROR 3515    An error was detected during material feed. Material jam occured
 ERROR 3516    An error was detected during material feed. Material jam in the output unit of the recorder has occured
 ERROR 3600    An internal error occurred when transferring the parameters
 ERROR 3601    An internal error occurred when transferring the parameters
 ERROR 3602    An internal error occurred when transferring the parameters
 ERROR 3700    A problem occurred in the material guide system
 ERROR 3701    A problem occurred in the material guide system
 ERROR 3702    A problem occurred in the material guide system
 ERROR 3703    A problem occurred in the material guide system
 ERROR 3704    A problem occurred in the material guide system
 ERROR 3705    A problem occurred in the material guide system
 ERROR 3706    A problem occurred in the material guide system
 ERROR 4000    Parameter set-up error 
 ERROR 4001    An error occurred during the initialization of the recorder hardware
 ERROR 4002    SlowScan feed error
 ERROR 4003    SlowScan feed error
 ERROR 4004    An error occurred in the SlowScan feed unit
 ERROR 4005    The dust cover and (or) the side panel are not closed
 ERROR 4006    The dust cover and (or) the side panel are not closed
 ERROR 4007    Material jam in the recorder
 ERROR 4008    An error occurred during the material width measurement
 ERROR 6000    An error occurred when accessing the non-volatile memory of the supply cassette
 ERROR 6001    An error occurred when accessing the non-volatile memory of the supply cassette
 ERROR 6002    An internal error occurred when accessing the non-volatile memory of the supply cassette
 ERROR 6003    A non-volatile memory is missing in the recorder
 ERROR 6004    The supply cassette has not been inserted
 ERROR 6005    An internal error occurred when accessing the non-volatile memories
 ERROR 6006    An internal error occurred when accessing the non-volatile memories
 ERROR 6007    An error occurred when accessing the non-volatile memories
 ERROR 6008    An error occurred when accessing the non-volatile memories
 ERROR 6009    An internal error occurred when accessing the non-volatile memories
 ERROR 7000    Internal operating system error
 ERROR 7001    Internal operating system error
 ERROR 7002    Internal operating system error
 ERROR 7003    Internal operating system error
 ERROR 7004    Internal operating system error
 ERROR 7005    Internal operating system error
 ERROR 7006    Internal operating system error
 ERROR 7800    No diskette or the wrong diskette has been inserted
 ERROR 7801    Diskette error: File cannot be opened
 ERROR 7802    Diskette error: File cannot be found
 ERROR 7803    Diskette error: File cannot be read
 ERROR 7804    Diskette error: File cannot be written
 ERROR 7805    Diskette error: File cannot be created
 ERROR 7806    Diskette error: File cannot be deleted
 ERROR 7807    Diskette error: File cannot be renamed
 ERROR 7808    Diskette error: Directory cannot be changed
 ERROR 7809    Diskette error: Directory cannot be created
 ERROR 780A    Diskette error: Diskette is write-protected
 ERROR 780B    The inserted diskette is no UPDATE diskette
 ERROR 780C    The inserted diskette is no recorder system diskette
 ERROR 7C3D    EEPROM Data read error has occured
 ERROR 7C3E    AC-fault greater than 50 milliseconds
 ERROR 7C40    A transmission error on LASERWAY has occured
 ERROR 7C41    The laser power is outside the ready range
 ERROR 7C42    Laser power mode – an adjust timeout has occured
 ERROR 7C43    Laser power supply – an over-temperature error on the passbank has occured
 ERROR 7C44    Laser module – the current limit is reached
 ERROR 7C45    Diode module safety loop test – a bad voltage was detected
 ERROR 7C46    Diode module safety loop check – a logic-fault was detected
 ERROR 7C47    Diode module safety check 2 – a bad voltage was detected
 ERROR 7C48    Diode module safety check 2 – a logic-fault was detected
 ERROR 7C49    Diode module safety check 1 – a bad voltage was detected
 ERROR 7C4A    Diode module safety check 1 – a logic-fault was detected
 ERROR 7C51    Diode module – the EEPROM data is not available
 ERROR 7C52    Diode module – a EEPROM data write failure has occured
 ERROR 7C53    Laser module – a bad microprocessor configuration was detected
 ERROR 7C54    Laser module – a failure of the cooling system was detected
 ERROR 7C55    Laser module – a failure of the heater system was detected
 ERROR 7C58    Diode module – the thermistor is shorted
 ERROR 7C59    Diode module – the thermistor is open
 ERROR 7C5B    Diode module – an over-temperature error has occured ( > 37.5 C)
 ERROR 7C5C    Diode module – an under-temperature error has occured ( < 7.5 C)
 ERROR 7C5D    Laser module – the current limit PASSBANK is reached (2)
 ERROR 7C5E    Laser module – the current limit PASSBANK is reached (1)
 ERROR 7C5F    The laser module safety loop is open
 ERROR 7C62    The diode module relay is closed but should be open
 ERROR 7C63    The diode module relay is open but should be closed
 ERROR 8000    Internal error
 ERROR 8001    Internal error
 ERROR 8002    An error occurred in the recorder hardware
 ERROR 8003    An error occurred in the recorder hardware
 ERROR 8004    An error occurred in the recorder hardware
 ERROR 8005    An error occurred in the recorder hardware
 ERROR 8100    A parameter set-up error occurred in the optics unit
 ERROR 8101    A parameter set-up error occurred in the optics unit
 ERROR 8102    A parameter set-up error occurred in the optics unit
 ERROR 8110    An error occurred in the optics unit of the recorder
 ERROR 8111    An error occurred in the optics unit of the recorder
 ERROR 8112    An error occurred in the optics unit of the recorder
 ERROR 8120    An error occurred in the optics unit of the recorder
 ERROR 8121    A parameter set-up error occurred in the optics unit
 ERROR 8122    A parameter set-up error occurred in the optics unit
 ERROR 8200    An error occurred in the mirror motor unit
 ERROR 8201    A parameter set-up error of the mirror motor unit occurred
 ERROR 8202    An error occurred in the mirror motor unit
 ERROR 8203    An error occurred in the mirror motor unit
 ERROR 8204    An error occurred in the mirror motor unit
 ERROR 8205    An error occurred in the mirror motor unit
 ERROR 8300    The voltage monitoring recognized an error
 ERROR 8301    The voltage monitoring recognized an error
 ERROR 8302    The voltage monitoring recognized an error
 ERROR 8303    The temperature monitoring of the optics unit recognized an error
 ERROR 8304    The temperature monitoring of the optics unit recognized an error
 ERROR 8310    An internal error occurred
 ERROR 83F1    An error occurred when preparing the optics for exposure
 WARNING A600    The recorder is in test operation mode
 WARNING AC00    The selected material is not in the supply cassette
 USER INFO CC00    The image data have not been all processed during the exposure
 USER INFO CC01    The *.RIF initialization file cannot be read from the diskette
 USER INFO CC02    The recorder hardware and software are incompatible
 USER INFO CC03    The recorder received an unacceptable application parameter from the RIP
 USER INFO CC04    The recorder received an unacceptable application parameter from the RIP
 USER INFO CC05    The recorder received an unacceptable application parameter from the RIP
 USER INFO CC06    The recorder received an unacceptable application parameter from the RIP
 USER INFO CC07    The recorder received an unacceptable application parameter from the RIP
 USER INFO CC08    The recorder received an unacceptable application parameter from the RIP
 USER INFO CC09    The recorder received an unacceptable application parameter from the RIP
 USER INFO D000    There is no diskette in the drive
 USER INFO D001    The diskette in the drive is defective or has a wrong format, e.g. DD(720KB)