07814 652568 steve@rsprepress.com

Heidelberg ProSetter

Error:             Description:                                                        More Details:
 0   Recorder is ready for operating    
 1   Internal Error   An error occurred in the program sequence 
 2   Internal Error   An error occurred in the program sequence
 12   Internal Error   Internal communication error
 35   An error occurred in a database.   The specified record is not available.
 36   An error occurred in a database.   The specified error got a different type.
 37   An error occurred in a database.   The length of the value of the specified error is to long for the delivered buffer
 38   An error occurred in a database.   The length of the buffer of the specified record is to short for the delivered value
 40   An error occurred in a database   The insertion of a record into a database is not possible
 41   An error occurred in the file system   A file could not be opened
 42   An error occurred in the file system   A file could not be closed
 43   An error occurred in the file system   A file could not be seeked
 44   An error occurred in the file system   A file could not be written
 45   An error occurred in the file system   A file could not be read
 48   An error occurred while allocating memory   Memory could not be allocated
 49   An error occurred while parsing a source   A syntax error is occurred
 94   Internal system error   Error using operating system function
 95   Internal system error   Error using operating system function
 96   Internal system error   Error using operating system function
 97   Internal system error   Error using operating system function
 98   Internal system error   Error using operating system function
 99   Internal system error   Error in file operation
 100   Internal system error   Error in file operation
 101   Internal system error   Error in file operation
 102   Internal system error   Error in file operation
 103   Internal system error   Error in file operation
 104   Internal system error   Error in file operation
 105   Internal system error   Error in file operation
 106   Internal system error   Error in file operation
 107   Internal system error   Error in file operation
 108   Internal system error   Error in file operation
 109   Internal system error   Error in file operation
 110   Internal system error   Error in file operation
 111   Internal system error   Error in file operation
 112   Internal system error   Error using operating system function
 113   Internal system error   Error using operating system function
 114   Internal system error   Error using operating system function
 115   Internal system error   Error using operating system function
 116   Internal system error   Error using operating system function
 117   Internal system error   Error using operating system function
 118   Internal system error   Error using operating system function
 119   Internal system error   Error using operating system function
 120   Internal system error   Error using operating system function
 121   Internal system error   Error using operating system function
 122   Internal system error   Error using operating system function
 123   Internal system error   Error using operating system function
 124   Internal system error   Error using operating system function
 126   Internal system error   Error in file operation
 128   Internal system error   Error in file operation
 129   Internal system error   Error in filebox
 130   Internal system error   Error in filebox
 133   Communication error   Speedway communication error
 134   Communication error   Speedway communication error
 135   Internal system error   Error using operating system function
 136   Internal system error   Error using operating system function
 146   Internal system error   Internal communication error
 147   Internal system error   Internal communication error
 148   Internal system error   Internal communication error
 149   Internal system error   Internal communication error
 150   Internal system error   Internal communication error
 151   Internal system error   Internal communication error
 152   Internal system error   Internal communication error
 153   Internal system error   Internal communication error
 154   Internal system error   Internal communication error
 155   Internal system error   Error using operating system function
 156   Internal system error   Error using operating system function
 157   Internal system error   Error using operating system function
 158   An error occurred in a database   The erasing of a record out of a database is not possible
 163   Internal system error   Error in file operation
 164   Internal system error   Error in file operation
 170   An internal hardware error occurred   FPGA busy error
 171   An internal hardware error occurred   FPGA detection error
 172   An internal hardware error occurred   FPGA initialization error
 173   An internal hardware error occurred   FPGA busy error
 174   An internal hardware error occurred   FPGA frame data error during configuration
 175   An internal hardware error occurred   FPGA length count error
 220   An error occurred in a database   A file which should be copied does not exist
 221   An error occurred in a database   A file could not be deleted
 222   An error occurred in a database   A file could not be copied
 223   An error occurred in a database   A directory could not be created
 224   An error occurred while parsing a source   A serious syntax error is occurred
 225   An error occurred while parsing a source   A serious syntax error is occurred
 234   Internal error   Operating system error
 235   Internal error   Operating system error
 237   An internal hardware error occurred   Communication error on the SPI Bus
 282   Internal system error   Error in Package
 283   Internal system error   Error in Package
 284   Internal system error   Error in FPGA box
 285   Internal system error   Error in FPGA box
 293   The current machine type is usable for test purposes only   The current machine type is usable for test purposes only
 294   The current machine type is invalid   The current machine type is invalid
 295   The current machine variation is invalid   The current machine variation is invalid
 313   Internal system error   Operating system error
 314   Internal error   Operating system error
 319   An error occurred while parsing a source   A semantics error occurred
 320   An error occurred while parsing a source   Simple semantics error
 321   An error occurred while parsing a source   Serious semantics error
 322   Switch off sequence initiated   Fast switch off sequence initiated
 323   Fast switch off sequence initiated   A second switch off command was received. Only data will be saved before switch 
 324   An error occurred in the parameter database   The parameter configuration file does not exist
 400   Internal error   Undefined error
 401   Internal error   Undefined error
 402   Internal error   Wrong magic number received with the data
 403   Internal error   Buffer size error
 404   Internal error   Checksum error
 405   Internal error   Error after select() function
 406   Internal error   select() timeout
 407   Internal error   Error after ioctl() function
 408   Internal error   Not enough buffer for download
 409   Internal error   Not enough buffer for download
 410   Internal error   Not enough FLASH memory
 411   Internal error   Unknown FLASH vendor
 412   Internal error   Unknown FLASH module
 413   Internal error   Invalid FLASH map
 414   Internal error   FLASH not ready
 415   Internal error   Error clearing the FLASH
 416   Internal error   Error clearing the FLASH
 417   Internal error   Error clearing the FLASH
 418   Internal error   Error clearing a FLASH sector
 419   Internal error   Error clearing a FLASH sector
 420   Internal error   Error checking a FLASH sector
 421   Internal error   Timeout programming the FLASH
 422   Internal error   FLASH not ready
 423   Internal error   Error comparing the FLASH after write operation
 424   Internal error   Error connecting with an interrupt
 425   Internal error   Error activating an interrupt
 426   Internal error   Out of init error memory
 427   Internal error   Error initializing the hardware
 428   Internal error   Error reading from FLASH
 429   Internal error   Error writing to FLASH
 430   Internal error   Error after open() function
 431   Internal error   Error after close() function
 440   Internal system error   Error using operating system function
 441   Internal system error   Error using operating system function
 442   Internal system error   Error using operating system function
 443   Internal system error   Error using operating system function
 3001   The ventilator for the central electronics is defective! Forcing power off of the recorder   Electronics ventilator monitor reports an error. You cannot continue operation. Powering down the recorder
 3002   Wrong Bacher punch configuration   Bacher Configuration parameter (PID 21958) is wrong. The bit map of the Bacher Configuration (PID 21958) must be a subset of the bit map of the Punch Configuration (PID 766)
 3003   The ventilator of the air filter is not working. There will be a loss of recorder quality due to dirty mirrors if this error occurs over a longer period of time   The ventilator of the air filter is not rotating or the phase sequence sensor is defective
 3004   The air filter is used and must be replaced. There will be a loss of recorder quality due to dirty mirrors if this error occurs over a longer period of time   The sensor for the air filter reports that the filter is used
 3005   Max. output level of the optical head is not enough to image in the selected mode   Max. output level of the optical head is not enough to image in the selected mode
 3006   Max. output level of the optical head is not enough to image in the selected mode   Cannot end an action in the recorder because of a preceding error or power-off function
 3007   Punch setting doesn’t match punch configuration   RIP punch action doesn’t match punch configuration
 3008   ATTENTION: Plate lost in device! Do NOT correct error   A plate was probably lost in the device during initialization. Error correction is illegal in this present state
 3009   Internal communication error   Communication with an internal assembly (e.g. Optic) failed
 3010   Internal communication error   Communication with with the Autoloader failed
 3011   Error in the slow scan unit   Could not find resolution for calculation of an imaging ramp
 3012   Network addresses (IP addresses) conflict   The two network addresses of the recorder must not come from the same network
 3014   An error occurred in the mirror motor unit   The time monitor reports timeout during the spin-up phase of the mirror motor
 3015   An error occurred in the mirror motor unit   The time monitor reports timeout during the spin-down phase of the mirror motor
 3016   An error occurred in the air supply unit   The air safety switch is not closed
 3017   An error occurred in the air supply unit   The mirror air cooler temperature is to high
 3018   An error occurred in the air supply unit   Communication error on the I2C-Bus
 3019   Internal communication error   The air pump did not start
 3020   An error occurred in the air supply unit   The focus stepping motor cannot find the zero position
 3021   An error occurred in the optic unit   The focus stepping motor cannot find the zero position
 3022   A parameter set-up error occurred in the optic unit   The focus position set point is not within the permissible range
 3023   An error occurred in the optic unit   The filter stepping motor cannot find the zero position
 3024   An error occurred in the optic unit   The filter stepping motor cannot leave the zero position
 3025   A parameter set-up error occurred in the optic unit   The filter number is not within the permissible range
 3026   A parameter set-up error occurred in the optic unit   The number of the shaping element is not within the permissible range
 3027   An error occurred in the optic unit   The adjust bias current of the laser diode is higher than the maximum current
 3028   An error occurred in the optic unit   The maximum bias current of the laser diode is not sufficient to achieve the required light value
 3029   An error occurred in the optic unit   The adjusted current of the laser diode is higher than the maximum current
 3030   A parameter set-up error occurred in the optic unit   The modulation current of the laser diode set to maximum is not sufficient to achieve the required light value
 3031   An error occurred in the optic unit   The laser diode must be on for the light stabilization
 3032   An error occurred in the optic unit   The light stabilization must be off
 3033   An error occurred in the optic unit   Passed value is to high for this function
 3034   An error occurred in the optic unit   Passed value is to low for this function
 3050   On board device error   Unable to set mirror power supply (36 V)
 3051   An error occurred in the slow scan unit   The stepper board signals a short circuit, the safety loop is open or power supply (36V) failed
 3052   An error occurred in the slow scan unit   The stepper board signals high temperature
 3053   An error occurred in the slow scan unit   The stepper board signals not ready
 3054   An error occurred in the slow scan unit   The carrier reaches the left limit
 3055   An error occurred in the slow scan unit   The carrier reaches the right limit
 3056   An error occurred in the slow scan unit   The carrier is moving when it is not allowed
 3057   An error occurred in the slow scan unit   The safety loop is not closed
 3058   An error occurred in the slow scan unit   An interrupt has occurred when not expected. Interrupt: Stop
 3059   An error occurred in the slow scan unit   An interrupt has occurred when not expected. Interrupt: Signal of light barrier has changed
 3060   An error occurred in the slow scan unit   An interrupt has occurred when not expected. Interrupt: Destination reached
 3061   An error occurred in the slow scan unit   A SlowScan timeout is occurred during finding a position or moving into the light barrier
 3062   An error occurred in the slow scan unit   A valid ramp could not be found
 3063   An error occurred in the slow scan unit   A ramp which fits into a specified distance could not be found
 3064   A parameter error occurred   The value of a parameter is not valid
 3078   An internal software error occurred   An attempt to read an uninitialized ADC device.
 3088   An error occurred while material handling   Timeout at build vacuum
 3089   An error occurred while material handling   Timeout at vacuum off
 3138   An error occurred at punch init   Punch not connected or not configured
 3159   An error occurred in the slow scan unit   The safety loop is not closed
 3160   An error occurred in the slow scan unit   The carrier reaches the left limit
 3161   An error occurred in the slow scan unit   The carrier reaches the right limit
 3162   An error occurred in the slow scan unit   The stepper board signals not ready
 3165   An error occurred while setting the light intensity   The BaseIntensity value for the selected resolution of the current job is lower than the adjustable light
 3168   An error occurred in the slow scan unit   The feed ramp could not be written
 3169   An error occurred in the slow scan unit   Error while calculating feed ramp data
 3198   Not calibrated resolution selected   The selected resolution is not calibrated. The BaseIntensity parameter for the selected resolution is zero
 3199   An communication error to the optic head occurred   The communication to the optic head is broken
 3200   An communication error to the optic head occurred   The communication to the optic head is faulty
 3201   An error occurred in the optichead unit   The number of gate impulses generated by the Image-Control is out of range
 3202   An error occurred in the optichead unit   The temperature of the laser diode did not change after switching on the temperature regulation
 3203   An error occurred in the optichead unit   The temperature of the laser diode is over the maximum allowed temperature
 3204   An error occurred in the optichead unit   A parameter transmitted to the optichead is out of range
 3205   An error occurred in the optichead unit   A parameter transmitted to the optichead is out of range
 3206   An error occurred in the optichead unit   An error without a defined event has occurred
 3207   An error occurred in the optichead unit   The light value on the laser diode with the bias current alone is higher than the value in the application data. This may be due to an error in the primesetter or a not initialized material data set or an defective optichead
 3208   An error occurred in the optichead unit   The error occurs if you switch on the temperature regulation on the optichead without a regulation device
 3209   An error occurred in the optichead unit   The mirror phased out during transmission. The mirror is not locked
 3211   The mirror phased out during transmission. The mirror is not locked   The detect vacuum is much too low
 3212   An error occurred while selecting the focus value   The RIP transmitted resolution is not a element of the recorder resolution table
 3213   An error occurred while selecting the focus value   The calculation of the spotshape value failed
 3214   An error occurred in the optic unit   The calculation of the filter value failed
 3215   An error occurred in the optic unit   The calculation of the physical focus value failed
 3216   An error occurred in the optic unit   The calculation of the physical focus value failed
 3217   The safety loop was at least briefly interrupted    
 3226   An error occurred while setting the light intensity   The BaseIntensity value for the selected resolution of the current job is lower than the adjustable light
 3227   An error occurred while setting the light intensity   The BaseIntensity value for the selected resolution of the current job is higher than the adjustable light
 3228   An error occurred in the optichead unit   The light value on the laser diode with the modulation current alone is to high . This may be due to an error in the primesetter or an defective optichead
 3229   An error occurred in the air supply unit   The high-water sensor is still active, after water blow-off
 3230   An error occurred in the air supply unit   The high-water sensor is still active, after water blow-off
 3238   Plate on table missing for load   Possibly plate detector (on plate table) defect
 3239   An error occurred at punch action   Timeout at punch action (10s) at arrive ls
 3240   An error occurred at material transport   Timeout at drive plate slider to Down-Wait Position (prepare to load)
 3241   An error occurred at material transport   Timeout at drive plate slider to Down-Free position (unload plate)
 3242   An error occurred at material transport   Timeout at drive plate slider to Up-Unload Position (unload plate or init)
 3243   An error occurred at material transport   Timeout at center plate on table
 3244   Plate on the table is not valid. Measured plate width is different to requested plate   Plate on the table is not valid. Measured plate width is different to requested plate
 3245   Inserted plate is not valid. Measured plate length is different to requested plate   Inserted plate is not valid. Measured plate length is different to requested plate
 3246   Unexpected plate on table detected. Exposed plate can not be ejected   Unexpected plate on table detected. Exposed plate can not be ejected
 3247   An error occurred at material transport   A timeout is occurred during moving the lift into a position. No interrupt occurred
 3248   There is no plate at the grip. Loading material isn’t possible   The plate sensor at the grip signals no-plate
 3249   An internal hardware error occurred   The lift stepping motor cannot find it’s zero position
 3250   An internal hardware error occurred. One or more fans at the back-wall don’t work   One or more of the guide fans at the back-wall don’t work
 3251   An internal hardware error occurred. One or more fans at the back-wall don’t work   One or more of the guide fans at the back-wall don’t work
 3252   An internal hardware error occurred. One or more fans at the back-wall don’t work   One or more of the guide fans at the back-wall don’t work
 3253   An internal hardware error occurred. One or more fans at the back-wall don’t work   One or more of the guide fans at the back-wall don’t work
 3254   The safety loop is open   The safety loop is open
 3255   An internal hardware error occurred   An internal hardware error occurred
 3256   An internal hardware error occurred   An internal hardware error occurred
 3258   Plate position in lift is not valid for unloading   Inserted plate is not valid. Measured plate length is different to requested plate
 3259   An error occurred at material transport   An error occurred at material transport
 3260   An error occurred at material transport   Moving the flaps failed. They didn’t reach their in-or-out target position
 3261   An error occurred at material transport   Moving the flaps failed. They didn’t reach their in-or-out target position
 3262   An error occurred at material transport   Lift didn’t reach it’s set position. Maybe stopped by a sporadic interrupt
 3263   An error occurred at material transport   Moving the lift isn’t possible because the flaps stays in the path
 3264   An error occurred at material transport   Moving the lift isn’t possible because the grip unit is in horizontal position
 3265   An error occurred at material transport   There are no valid parameter available
 3266   An error occurred at material transport   Lift lost it’s position. Lower reference light-barrier shows a position error bigger than 1.2mm 
 3267   Material Length isn’t possible to load   It isn’t possible to move the lift into the calculated load position for this material length
 3269   An error occurred at material transport   This operation isn’t possible at this time because the system wasn’t initialized correctly 
 3270   The set lift position is out of range   It isn’t possible to move the lift into the calculated load position for this material length 
 3271   An error occurred at material transport   There are no valid parameter available 
 3272   An error occurred at material transport   Initializing of the lift not possible – maybe the grip is still under the hooks in the indrum 
 3274   An error occurred in the lift and grip unit   The stepper board signals not ready
 3275   An error occurred in the lift and grip unit   The lift ramp could not be written
 3276   An error occurred in the lift and grip unit   Error while calculating lift ramp data
 3277   An error occurred in the lift and grip unit   Moving the lift isn’t possible because the flaps stays in the path
 3278   An error occurred in the lift and grip unit   FPGA and Parameter Grip Mode do not match
 3279   part of the covering isn’t closed correctly or the emergency switch is activated    
 3280   Exposed plate is keeping in recorder   Exposed plate is keeping in recorder
 3281   The service switch bypasses the safety loop    
 3286   Unexpected plate on table detected. Init recorder or error correction not possible   Unexpected plate on table detected. Init recorder or error correction not possible
 3287   An error occurred in the lift and grip unit   The lift stepping motor cannot find it’s zero position
 3288   An internal hardware error occurred. One or more fans at the plate-table don’t work   One or more of the guide fans at the plate-table don’t work
 3289   An internal hardware error occurred. One or more fans at the plate-table don’t work   One or more of the guide fans at the plate-table don’t work
 3296   Voltage failure    The negative analog 5 V failed 
 3297   Voltage failure    The negative analog 5 V failed 
 3298   Voltage failure    The negative analog 5 V failed 
 3299   Voltage failure    The positive 36 V failed 
 3300   Voltage failure    The positive 15 V failed
 3301   Voltage failure    The positive 42 V failed
 3302   Voltage failure    The positive 7.5 V failed 
 3303   Voltage failure    The positive 7.5 V failed 
 3304   Voltage failure    The positive analog 24 V failed 
 3305   Voltage failure    The positive 3.3 V failed 
 3306   Voltage failure    The positive 2.5 V failed 
 3307   The positive 2.5 V failed    Safety loop check failed. Check the Logfile for further information
 3309   An error occurred in the material base   The requested material does not exist
 3310   An error occurred at material transport   The plate center unit does not left the light barrier
 3311   An error occurred at material transport   An unexpected motor stop from stepper counter at plate centering
 3312   An error occurred in the air supply unit   The air pressure did not reach the required minimum
 3315   The aging of the laser diode has accelerated   Too few exposure time has elapsed since the last automatic increase of the bias current setvalue. Nevertheless the bias current setvalue will be increased
 3316   The end of lifetime of the laser diode is approaching   The nominal maximum limit of the total current of the laser diode has been reached
 3317   An error occurred in the air supply unit   The mirror air pressure is above stop-limit
 3318   An error occurred in the air supply unit   The mirror air pressure is above stop-limit
 3325   An error occurred in the material base. The preferred shaft has not been specified   The preferred shaft is used in case a material shall be loaded which gets no link from any shaft
 3326   An error occurred in the material base   The name of the material that is send with the command request material is invalid
 3327   Remove Plate from table. Plate is exposed   Remove Plate from table
 3328   Remove Plate from table. Plate is unexposed   Remove plate from manual tray
 3329   OLP program change necessary   OLP program change necessary
 3913   Autoloader error state detected   Autoloader error state detected
 3914   Internal software or parameter error   Syntax error in debug configuration
 3915   The Emergency Switch is activated    
 3916   The boot sequence failed. Please reboot the system   The boot sequence failed. Please reboot the system
 4001   Internal software or parameter error   Syntax error in debug configuration
 4002   Execution error – A general STOP occurred   A general BREAK occurred
 4003   Internal error – sensor not recognized   A sensor in the device does not respond
 4004   Internal error – setting a sensor failed   Writing to a sensor failed
 4005   Internal error – actuator not recognized   An actuator in the device does not respond
 4006   An actuator in the device does not respond   Writing to an actuator failed
 4007   Error checking the Cassette/Waste safety loop   There is a problem with the safety loop of the Cassette / Waste section. Checking it failed
 4008   Invalid Autoloader machine type set    
 4009   Any part of the covering isn’t closed correctly    
 4010   The safety loop was at least briefly interrupted    
 4011   The service switch bypasses the safety loop    
 4012   Internal system error   Error using operating system function
 4013   Error checking the cover safety loop   There is a problem with the safety loop of the cover section. Checking it failed
 4014   Runtime error   Internal software error
 4015   The Emergency Switch is activated    
 4016   The boot sequence failed. Please reboot the system   The boot sequence failed. Please reboot the system
 4100   Error separating a plate    
 4101   Error initializing the shutter   Unable to access the shutter init sensor
 4102   Error initializing the shutter   Unable to quit the shutter init sensor
 4103   Error moving the shutter   Unable to move the shutter into waste position
 4104   Error moving the shutter   The shutter failed to get to the material transfer position
 4105   Error polling a load table plate sensor   Load table plate sensor on the suction cart not found
 4106   Error separating   Plate lost while separating or during transport to the entry of the load table plate. The plate did not arrive at the relevant sensor
 4107   Error placing the plate on the load table plate   Plate lost during transport to the load table plate, the table plate sensor on the suction cart fails to detect the plate at the end of the transfer process
 4108   Error moving the shutter   Separator exit sensor not left when transporting the plate to the load table plate
 4109   Paper sheet lost when separating   When depositing the paper sheet, the vacuum shows that the sheet was lost during transfer into the waste container
 4110   Error initializing the stripper unit   Stripper unit did not arrive at the init position during initialization
 4111   Error initializing the stripper unit   Unable to quit the init sensor of the stripper unit
 4112   Error moving the stripper unit into working position   Unable to quit the parking sensor of the stripper unit
 4113   Error moving the stripper unit   Unable to get to the parking sensor of the stripper unit
 4115   Moving the stripper unit into the parking position caused an error several times   Moving the stripper unit into the parking position caused an error several times
 4116   A sensor was not reached while the stripper unit was moving to its park position   The light barrier of the park sensor was not detected while the stripper unit was moving to its park position
 4117   A sensor was not reached during initialization of the stripper unit   The light barrier of the park sensor was not detected during initialization of the stripper unit
 4118   A sensor was not reached during normalization of the shutter   A sensor was not reached during normalization of the shutter
 4119   A sensor was not reached during initialization of the shutter   The zero light barrier was not detected during initialization of the shutter
 4120   Error initializing the cassette shutter   Cassette shutter motor did not arrive at the init position during initialization
 4121   Error initializing the cassette shutter   Unable to quit the init position when initializing the cassette shutter motor
 4122   Error while preparing cassette shade drive for taking a new cassette   Sensor could not detect the requested phase 1 during the specified number of attempts during initialization of the cassette shade drive
 4123   Error while preparing cassette shade drive for taking a new cassette   Sensor could not detect the requested phase 2 during the specified number of attempts during initialization of the cassette shade drive
 4124   A sensor was not reached during initialization of the cassette shade drive   The light barrier of the close sensor was not detected during initialization of the cassette shade drive
 4130   Error moving the suck bar   The suck bar did not arrive in its new position during the expected time
 4133   Error lowering the suck bar   The suck bar is not at its bottom position as expected
 4134   Error moving the suck bar   The suck bar is not at the middle position as expected
 4135   Error lifting the suck bar   The suck bar is not at the top position as expected
 4136   Error moving the suck bar   The suck bar does not move
 4137   Error setting the suck bar parameters   A command to the suck bar returned an invalid command
 4138   While separating, double sheet error Paper under plate occurred several times without a plate being present   While separating, double sheet error Paper under plate occurred several times without a plate being present
 4139   A piece of paper, located on the Jalousie, couldn’t fix by the suck bar   A piece of Paper couldn’t move from the suck bar to the Jalousie suction bar
 4140   Error setting the separator ejector parameters   Invalid command encountered when enabling the ejector’s blowing function
 4141   Error setting the separator ejector parameters   Invalid command encountered when enabling the ejector’s suction function
 4142   Error setting the separator ejector parameters   Invalid command encountered when actuating the compressed air supply of the ejector’s suck bar
 4143   Error setting the separator ejector parameters   Invalid command encountered when actuating the compressed air supply of the ejector’s suction bar
 4144   Vacuum error signaled by vacuum sensor. Unable to suck and hold the material or material lost   The vacuum sensor of the separator detected an insufficient vacuum
 4152   Error setting the double sheet sensor parameters   Invalid command encountered when selecting the double sheet sensor
 4153   No or not enough compressed air   Poll of compressed air status result: no compressed air
 4154   Error separating. A double sheet detected cannot be separated because the suction bar is carrying material already    
 4155   A double sheet detected on the jalousie. The material could not be separated   The double sheet must be removed manually by hand
 4156   A double sheet was detected on the Jalousie. The material couldn’t be split   The double sheet couldn’t fix by the suck bar – it must be removed by hand
 4157   A double sheet was detected on the Jalousie. The material couldn’t be split   The double sheet couldn’t fix by the suck bar – it must be removed by hand
 4161   Tray empty. No material on the active tray   No material found when reading the tray fill level
 4162   A detected double sheet on the Jalousie couldn’t move to the Load Table   A double sheet wasn’t detected from the exit-sensor of the separator
 4163   A double sheet was detected on the Jalousie. The material couldn’t be split within several tries   The double sheet couldn’t be split within several tries – it must be removed by hand
 4164   While checking the material at the suction bar, an error with the vacuum occurred    
 4165   While sucking the paper with the suck bar, a vacuum error occurred   There was no vacuum at the suction bar
 4166   The paper could not be removed, because the cassette was not open    
 4167   While loading and locking the cassette an error occured inside the SCL    
 4171   Clamp jaw unit error   Unable to close the clamp jaw
 4172   Clamp jaw unit error   Unable to open the clamp jaw unit – the unit will not release the plate
 4173   Error closing the clamp jaw unit   Unable to close the clamp jaw unit during the expected time
 4174   Error closing the clamp jaw unit   Unable to open the clamp jaw unit during the expected time
 4181   No material found in the cassette   No material was detected during check of cassette level
 4182   Almost no material in the cassette   A check of the cassette level detected only a few plates still in the cassette. The number has fallen below the set alert level
 4183   The waste container is full   A check of the waste container level detected that the container is full
 4184   The waste container is almost full   A check of the waste container level detected that the set alert level was exceeded
 4190   Error setting the waste container parameters   Invalid command encountered when opening / closing the waste container
 4191   Unable to open the waste container   The waste container could not be opened because it was impossible to move the shutter into the specified position
 4192   Waste container open   Could not open the cassette because the waste container was not closed
 4193   Vacuum error at the suction bar. Could not suck the material to the bar or the material was lost   Vacuum sensor detected that the vacuum was too low when the suction bar of the separator was used
 4194   Vacuum error after raising the suction bar. Could not suck the material to the bar or the material was lost   Vacuum sensor detected that the vacuum was too low after raising the suction bar
 4195   Configuration error – unknown machine type   Invalid machine type set
 4196   Error separating   Plate lost while separating or during transport to the entry of the load table plate. The plate did not arrive at the relevant sensor
 4197   Error separating   Material lost when lifting it out of the tray
 4198   An error occurred during initialization or error handling. Material was found on the shutter   Material was found on the shutter during initialization or error handling. The material is to be removed by the operator
 4201   Unable to determine the position of the load table plate   Both load table plate position sensors output the same signal
 4202   Error moving the load table   Timeout encountered when swivelling/moving the load table
 4203   The load table fans are not working    
 4204   Error moving the plate holder   Timeout encountered when lifting/lowering the plate holder
 4205   Error initializing the plate holder   The plate holder did not move away from its init sensor
 4206   Error initializing the plate drive motor   The plate holder did not move up to its init sensor
 4207   Error initializing the plate drive motor   Initialization of the plate drive motor failed. Absolute positioning of the plate holder is not possible
 4208   No plate on the load table   The procedure requires a plate but none has been detected
 4209   Error initializing the center unit   The center unit did not move away from its init sensor
 4210   Error initializing the center unit   The center unit did not move up to its init sensor
 4211   Material transport error   Error transporting the plate from the load table to the conveyor
 4212   Plate not in the gripper   The plate did not move up to the grip sensor
 4213   The plate did not move up to the grip sensor   Wrong width of plate. See the log file for further details
 4214   Load table process error   A signal expected from the load table holder sensor not received
 4215   Error initializing the load table   The states of the load table sensors have been checked. The result is an impossible combination
 4226   Double sheet detected on load table during material transport to recorder   Please remove the material manually by hand
 4227   The load table can not be moved, because material was detected between separator and load table   Material was detected in light barrier of the separator. The material is to be removed by the operator before moving the load table
 4301   Error moving the conveyor   Timeout lifting/lowering the conveyor table
 4302   Error initializing the conveyor roller motor   Initialization of the conveyor roller motor failed
 4303   Error transporting the plate from the conveyor to the load table   Plate transport from the conveyor to the load table is not possible. The plate has left the range of the entry sensor already
 4304   Error centering the plate on the conveyor   Unable to fully load the plate onto the conveyor. The conveyor entry sensor is not free
 4305   No plate on the conveyor   The procedure requires a plate but none has been detected
 4306   Configuration error – no valid assembly position of the online processor   Assembly position of the online processor wrong or not specified
 4307   Error centering the plate on the conveyor   Conveyor center sensor not enabled
 4308   Error initializing the conveyor slider   The conveyor slider did not move away from its init sensor
 4309   Error initializing the conveyor slider   The conveyor slider did not move up to its init sensor
 4310   Error initializing the conveyor slider   Initialization of the conveyor slider motor failed
 4311   Error unloading the plate   Signal expected from the conveyor entry sensor not received
 4312   Conveyor process error   Signal expected from the conveyor slider init sensor not received
 4313   Error actuating the online processor   No ON signal of the online processor
 4314   Error actuating the online processor   No connect signal of the online processor
 4315   Configuration error – wrong online processor interface set   The set online processor interface is unknown
 4316   Error unloading the plate   Error centering the plate on the conveyor. The computed correction exceeds the maximum
 4317   Error unloading the plate   Signal expected from the conveyor exit sensor not received
 4318   Error unloading the plate   Signal expected from the conveyor center sensor not received
 4319   Error initializing the conveyor   The states of the conveyor sensors have been checked. The result is an impossible combination
 4320   Error centering the plate on the conveyor   Unable to readjust the plate onto the conveyor. The plate is expected on the entry sensor but isn’t there
 4401   An error occurred while swinging out the cassette drive   One of the two cassette drives did not reach its swing-out position in the allotted time
 4402   An error occurred while swinging out the cassette drive   One of the two cassette drives did not leave its swing-out position in the allotted time
 4403   An error occurred during the cassette drive setup   An invalid command for the cassette drive was detected
 4404   An error occurred while evaluating the current cassette position   The sensors for the horizontal cassette position returned an invalid position
 4405   No cassette was detected at the MCL exit when conveying a cassette from the SCL to the MCL   The exit sensor of the MCL did not detect a cassette
 4406   No cassette was detected at the MCL entry when loading a cassette   The cassette drive sensor (perhaps the entry sensor as well) did not detect a cassette
 4407   No fully loaded cassette was detected while unloading a cassette from the MCL    
 4408   A cassette could not be positioned correctly while loading it from the SCL   The specified number of attempts to position the cassette was exceeded
 4409   A cassette could not be positioned correctly while loading it from the trolley   The specified number of attempts to position the cassette was exceeded
 4410   Error closing the inlet door   The inlet door did not reach the position in the allotted time
 4411   Error opening the inlet door   The inlet door did not reach the position in the allotted time
 4412   An error occurred while evaluating the current inlet door position   The sensors for the inlet door position returned an invalid position
 4413   An error occurred during the setup of the inlet door drive   An invalid command for the inlet door drive was detected
 4414   The inlet door was not open before a cassette was unloaded to the trolley    
 4415   The inlet door was not closed before the elevator moved    
 4420   Error initializing the elevator   The elevator init sensor was not reached
 4421   Error initializing the elevator   The elevator init sensor was not left
 4422   An error occurred while evaluating the current elevator position   The sensors for the vertical cassette position detected an invalid position
 4423   Failed to find cause of aborted movement after elevator or cassette drive finished moving   The cause was an undefined event
 4424   The elevator or cassette drive did not finish moving by reaching a sensor    
 4425   An error occurred while moving the elevator   The error bit of the elevator motor is active
 4426   A safety error occurred before the elevator moved   One of the two cassette drives is not swung out
 4427   A safety error occurred before the elevator moved   The cassette in the SCL was not locked
 4428   An error occurred while evaluating the current elevator position   The sensors for the vertical cassette position returned an invalid position
 4429   An error occurred during the elevator setup   An invalid command for the elevator was detected
 4440   No fully loaded cassette was detected before unloading a cassette from the MCL to the SCL or the trolley    
 4441   No fully loaded cassette was detected after loading a cassette from the SCL or the trolley  to the MCL    
 4442   No cassette was detected at the MCL entry sensor before loading a cassette from the SCL to the MCL    
 4443   No cassette was detected at the MCL exit sensor after unloading a cassette from the MCL to the SCL    
 4444   No cassette was detected at the MCL entry sensor before loading a cassette from the trolley to the MCL    
 4445   No cassette was detected at the MCL entry sensor after unloading a cassette from the  MCL to the trolley    
 4446   A cassette was detected to be not fully loaded to its position before the elevator moved    
 4447   The cassette is not in valid position    
 4448   No trolley was found in front of the MCL before unloading a cassette from the MCL    
 4449   A cassette was detected in the SCL before unloading a cassette from the MCL to the SCL    
 4450   The elevator could not be moved or movement had to be stopped too soon because the cassette drive was no longer swung out    
 4451   An error occurred, at least one safety relay of the MCL is open    
 4460   Movement of elevator started, duration approximately 90 sec    
 4461   Movement of elevator started, duration approximately 60 sec    
 4462   Movement of elevator started, duration approximately 30 sec    
 4500   No tray with the requested material   Further processing will be paused until a tray with the requested material has been put in
 4501   The waste container is open   Further processing will be paused until the waste container has been closed
 4502   The load table is not free. The system may be waiting for a plate to be moved on into the online processor   Further processing will be paused until the load table is free again
 4503   The conveyor is not free. The system may be waiting for a plate to be moved on into the online processor   Further processing will be paused until the conveyor is free again
 4504   The trolley is not in loading/unloading position   Further processing will be paused until the trolley is in the correct position
 4505   Online processor not ready – no connect signal   Further processing will be paused until a connect signal has been received from the online processor
 4506   The online processor is off   Further processing will be paused until the online processor is on and has sent a ready signal
 4507   The online processor is busy   Further processing will be paused until the state of the online processor has changed from Busy to Not Busy
 4508   The paper container is full   Further processing will be paused until the paper container has been opened and emptied
 4509   Tray empty   Further processing will be paused until the tray has been removed, filled with material and put back in
 4510   No or not enough compressed air   Further processing will be paused until the pressure level has reached the required value
 4511   Remove the cassette   Further processing will be paused until the cassette has been removed
 4512   Insert required plate to bypass   Insert required plate to bypass
 4513   Remove plate from bypass. Plate width is not as requested   Remove plate from bypass
 4520   Shaft data inconsistency detected. Rescan initiated (approx. 120 sec.)    
 4530   Error executing comand   The DAL command is not implemented
 4531   Error executing command   The DAL command was rejected
 4532   Error loading/unloading a cassette   Loading/unloading the cassette to the specified tray was impossible as the tray already contained a cassette
 4533   Error loading/unloading a cassette   The specified tray number is out of ra
 4534   Error loading/unloading a cassette   The specified tray type is incorrect
 4535   Error loading/unloading a cassette   The state of the specified tray is incorrect
 4536   Initialization failed   The initialization loop exceeded the maximum
 4537   Error Correction failed   The error correction loop exceeded the maximum
 4538   Shut down failed   The shutdown loop exceeded the maximum
 4988   An error was detected in the horizontal drive of the MCL   The elevator’s motor control detected an error and switched itself off
 4989   Error initializing a motor   Unable to quit the home sensor
 4990   Error initializing a motor   Expected home sensor not found at the target position
 4991   Error controlling a motor   Expected sensor not found at the target position
 4992   Error controlling a motor   Invalid parameter found when computing the data for stepper motor actuation
 4993   Error controlling a motor   No actuation data found when starting the stepper motor
 4994   Error controlling a motor   Insufficiently larger memory range found when computing the data for stepper motor actuation
 4995   Error controlling a motor   Absolute motor positioning not possible, the motor is to be initialized first
 4996   Error controlling a motor   Timeout actuating the stepper motor
 4997   Error controlling a motor   Invalid minimum frequency for actuating the stepper motor
 4998   Error controlling a motor   Invalid parameter found when computing the data for stepper motor actuation
 4999   Error controlling a motor   Error computing the data for actuating the stepper motor

Topsetter 74 / Acento II / Screen PT-R4xxx

Error:            Description:
 Ex101
   Nip roller does not ascend
 Ex102    Nip roller does not descend
 Ex103    Transport unit does not ascend
 Ex104    Transport unit does not descend
 Ex105    Trail clamp arm does not ascend
 Ex106    Trail clamp arm does not descend
 Ex107    Squeeze roller does not descend
 Ex108    Squeeze roller does not ascend
 Ex109    Trail clamp cannot be locked. PH24-1/2 or M24 is illegal
 Ex10a    Trail clamp cannot be unlocked. PH24-1/2 or M24 is illegal
 Ex10b    Balancer drive pin cannot be initialized
 Ex10c    Both of the Home and Away side drive pins for the balancer can not be pulled out
 Ex10d    Both of the Home and Away side drive pins for the balancer can not be inserted
 Ex10e    Bar for releasing the lead clamp does not ascend
 Ex10f    Bar for releasing the lead clamp does not descend
 Ex110    Shutter does not open
 Ex111    Shutter does not close
 Ex112    Plate size (in the Y direction) is shorter than the set value
 Ex113    When the plate is unloaded, the plate pass sensor (PH54-2) does not switch to ON
 Ex114    Not bring down squeeze at loading
 Ex115    Plate size (in the Y direction) is longer than the set value
 Ex116    Servo status is illegal
 Ex117    Servo status is error
 Ex118    Servo alarm
 Ex11a    Drum speed is set beyond the permitted rate of the servo controller
 Ex11b    Current drum’s encoder pulse is beyond 4000
 Ex11c    Error has occurred during drum positioning
 Ex11d    When the clamp is locked, some tail clamps are detected on the clamp arm, or when the clamp is unlocked, some tail clamps are not detected on the clamp arm
 Ex11e    Drum’s encoder pulse is beyond the permitted range after drum positioning
 Ex11f    Plate cannot be transferred into the transport unit
 Ex120    Home side balancer pin cannot be detected before insertion
 Ex121    Home side balancer pin cannot be detected before pulled out (The balancer is not moving).
 Ex122    Clamp arm and squeeze roller do not descend
 Ex123    Trail clamp is half-locked
 Ex124    The plate passing-sensor for unloading (PH54) does not switch to ON
 Ex125    Time-out error has occurred when the squeeze roller ascends and clamp cam
 Ex126    There was no plate to move to the shutter
 Ex127    Servo controller does not enter the “Ready” status
 Ex128    The balancer search sensor has not detected a balancer
 Ex129    Error has occurred on the Home side of the alignment plate (while the alignment plate is returning to its origin)
 Ex12a    Error has occurred on the Away side of the alignment plate (while the alignment plate is returning to its origin)
 Ex12b    Error has occurred on the Home and Away sides of the alignment plate (while the alignment plate is returning to its origin)
 Ex12c    Error has occurred on the Home side of the alignment plate (while alignment is performed)
 Ex12d    Error has occurred on the alignment plate (while alignment is performed)
 Ex12e    Error has occurred on the Home and Away sides of the alignment plate (when alignment is performed)
 Ex12f    Plate has not transferred to the punch unit
 Ex130    Plate does not leave the punch unit
 Ex131    Time-out error has occurred when Punch 1 is activated
 Ex132    Time-out error has occurred when Punch 2 is activated
 Ex133    Time-out error has occurred when Punch 3 is activated
 Ex134    Time-out error has occurred when Punch 4 is activated
 Ex135    Time-out error has occurred when Punch 5 is activated
 Ex136    Time-out error has occurred when Punch 6 is activated
 Ex137    Time-out error has occurred when Punch 7 is activated
 Ex138    Time-out error has occurred when Punch 8 is activated
 Ex139    After a plate is transferred to the gripper clamp, the plate detection sensor (PH29H/A) does not switch to ON
 Ex13a    When the clamp arm is lowered, the sensor (to detect whether the clamp arm pins are hooked on the clamp properly) has been turned ON.(Home side)
 Ex13b    The specified encoder pulse for the drum is beyond 4000
 Ex13c    The transport unit’s Away side is not moving during its operation
 Ex13d    The transport unit’s Home side is not moving during its operation
 Ex13e    Error has occurred on the Home side of the alignment plate (while the alignment plate is finely returning to its origin)
 Ex13f    Error has occurred on the Away side of the alignment plate (while the alignment plate is finely returning to its origin)
 Ex140    Error has occurred on the Home and Away side of the alignment plate (while the alignment plate is returning to its origin)
 Ex141    A plate remains in the transport unit when the machine received a request command
 Ex142    A plate remains in the transport unit during error handling
 Ex143    A plate remains on the discharge table in the transport unit
 Ex144    A plate remains on the insertion table in the transport unit
 Ex145    Plate cannot be moved onto the discharge table during initialization
 Ex146    Plate cannot be moved onto the insertion table
 Ex147    Balancer search operation has not been completed properly
 Ex148    When the transport unit descends, only the Home side Down sensor in the transport unit is turned ON
 Ex149    When the transport unit descends, only the Away side Down sensor in the transport unit is turned ON
 Ex14a    When the transport unit ascends, only the Home side UP sensor in the transport unit is turned ON
 Ex14b    When the transport unit ascends, only the Away side UP sensor in the transport unit is turned ON
 Ex14c    Front, rear or side cover is open. (Some interlock switches are OFF)
 Ex14d    A fuse on the relay board was blown. (home)
 Ex14e    Thumbscrew is not tightened securely on the rear cover. (The servo stop switch is ON)
 Ex14f    A plate exists on the discharge table in the transport unit during initialization
 Ex150    A plate exists on the insertion table in the transport unit during initialization
 Ex151    Number of balancers is not sufficient. (The number of balancers checked by the balancer search sensor was one, two or three for both the Home and Away sides)
 Ex152    Clamp arm is not in the UP position
 Ex153    A fuse on the relay board was blown. (away)
 Ex154    Blower is turned off, but signal does not change
 Ex155    Tail clamps are missing during initialization
 Ex156    The size check program of the cetering function detects that the measured plate size is longer than the expected one
 Ex157    The size check program of the cetering function detects that the measured plate size is shorter than the expected one
 Ex158    Both of Home and Away size check sensors are on before starting the centering program
 Ex159    Auto-loader is stopped by a interlock OFF
 Ex15a    This hardware matching is illegal
 Ex15b    The balancer is not moved to the target position
 Ex15c    The drum can not be spun up because the Home-Upper sensor of the Lead clamp release bar is off
 Ex15d    During plate loading, double plate loading is detected
 Ex15e    The loaded plate is detected to be floating while drum spinning
 Ex15f    The drum cannot be spun up because the Upper sensor of the clamp arm is off
 Ex160    The drum can not be spined up because the Home-Upper sensor of the clamp arm is off
 Ex161    The drum cannot be spun up because the balancing pin on the (Away side) is not in the waiting position
 Ex162    The drum cannot be spun up because the balancing pin on the (Home side) is not in the waiting position
 Ex163    The drum cannot be spun up because the Upper sensor of the squeeze roller is off
 Ex164    The drum can not be spun up because the Away-Upper sensor of the Lead  clamp release bar is off
 Ex165    The drum is rotated to the “lead clamp position”, but the status of the Servo controller (SVC) has not changed to “Ready”
 Ex166    The drum is rotated to the “tail clamp position”, but the status of the Servo controller (SVC) has not changed to “Ready”
 Ex167    The drum is rotated to the “squeeze position”, but the status of the Servo controller (SVC) has not changed to “Ready”
 Ex168    The drum is rotated to the “balance pin before inserted”, but the status of the Servo controller (SVC) has not changed to “Ready”
 Ex169    The drum is rotated to the “balance pin after inserted”, but the status of the Servo controller (SVC) has not changed to “Ready”
 Ex16a    The drum is rotated to the “pick up tail clamp position”, but the status of Servo controller (SVC) has not changed to “Ready”
 Ex16b    The drum is rotated to the “plate removal position”, but the status of the Servo controller (SVC) has not changed to “Ready”
 Ex16c    SVC Error has occurred during drum positioning for the lead clamp
 Ex16d    SVC Error has occurred during drum positioning for the tail clamp
 Ex16e    SVC Error has occurred during drum positioning for the squeeze
 Ex16f    SVC Error has occurred during drum positioning for the balance pin insertion
 Ex170    SVC Error has occurred during drum positioning for the balance pin pull out
 Ex171    SVC Error has occurred during drum positioning for the picking up tail clamp
 Ex172    SVC Error has occurred during drum positioning for the plate removal
 Ex173    Time-out error has occurred during drum positioning (Lead clamp position)
 Ex174    Time-out error has occurred during drum positioning (Tail clamp position)
 Ex175    Time-out error has occurred during drum positioning (Squeeze position)
 Ex176    Time-out error has occurred during drum positioning (Balance pin before inserted)
 Ex177    Time-out error has occurred during drum positioning (Balance pin after inserted)
 Ex178    Time-out error has occurred during drum positioning (Pick up tail clamp)
 Ex179    Time-out error has occurred during drum positioning (Plate removal)
 Ex17a    After verifying the removal of the plate, press the OK button. When the OK button is pressed, initialization begins
 Ex17b    PH62A-sensor is illegal. The sensor detects a plate during initialization
 Ex17c    PH29H-sensor is illegal. The PH29H-sensor does not turn ON during initialization
 Ex17d    PH61H-sensor is illegal. The sensor detects a plate during initialization
 Ex17e    PH61A-sensor is illegal. The sensor detects a plate during initialization
 Ex17f    PH29A-sensor is illegal. The PH29A-sensor does not turn ON during initialization
 Ex180    Drum does not start rotating at high-speed
 Ex181    Drum does not rotate at the specified high-speed
 Ex182    Error has occurred after the drum rotated at the specified high-speed
 Ex183    Drum cannot be stopped when rotating at high-speed
 Ex184    Drum operation is stopped with an emergency stop command
 Ex185    Drum operation is stopped with an abort command
 Ex186    Drum’s vacuum pressure is not sufficient. Please confirm connection of the blower-hose, or the Vacuum-sensor is illegal
 Ex187    Error has occurred on the blower, or the power supply of the blower is OFF
 Ex188    Drum operation is stopped due to low pressure in the drum
 Ex189    Door is open
 Ex18a    Door does not open
 Ex18b    Transport tasks: Parameter error
 Ex18c    Error has occured on the blower. Please turn off this machine, and turn on after waiting 10 seconds. Also, confirm whether or not the connector doesn’t come off
 Ex18d    The drum can not be spun up, because some of the interlock switches are OFF, or some of the actuator’s sensors are damaged, or the blower is damaged
 Ex18e    Door does not open, because some of the interlock switches are OFF (front cover or rear cover is open)
 Ex190    Clamp arm does not descend (Home side)
 Ex191    Clamp arm does not descend (Away side)
 Ex192    Clamp arm does not ascend (Home side)
 Ex193    Clamp arm does not ascend (Away side)
 Ex194    When the clamp arm is lowered, the sensor (to detect whether the clamp arm pins are hooked on the clamp properly) has been turned ON (Away side)
 Ex195    Trail clamp cannot be locked (Home side)
 Ex196    Trail clamp cannot be locked (Home side)
 Ex197    Trail clamp cannot be unlocked (Home side)
 Ex198    Trail clamp cannot be unlocked (Away side)
 Ex199    Balancer drive pin cannot be inserted (Home side) Either of PH11-1H,PH11-2H or M11H is illegal
 Ex19a    Balancer drive pin cannot be inserted (Away side) Either of PH11-1A,PH11-2A or M11A is illegal
 Ex19b    Balancer drive pin cannot be pulled out (Home side) Either of PH11-1H,PH11-2H or M11H is illegal
 Ex19c    Balancer drive pin cannot be pulled out (Away side) Either of PH11-1A,PH11-2A or M11A is illegal
 Ex19d    Balancer pin cannot be detected before insertion (Away side)
 Ex19e    Balancer pin cannot be detected before pull out (the balancer is not moving) (Away side)
 Ex19f    The balancer search sensor has not detected a balancer.(Home side)
 Ex1a0    The balancer search sensor has not detected a balancer.(Away side)
 Ex1a1    Number of balancers is not sufficient. (Home side)
 Ex1a2    Number of balancers is not sufficient. (Away side)
 Ex1a3    Soft-interlock or drum-stop swtich is OFF during drum spinning
 Ex1a4    The cover-interlock switch is OFF during drum 
spinning Ex1a5    The interlock switch-3 is OFF during drum spinning
 Ex1a6    A plate cannot be carried into the transport unit
 Ex1a7    A plate cannot be carried to sensor PPH50-2
 Ex1a8    Auto-loader is not turned on, or some interlock switches on Auto-loader are OFF. Please turn on Auto-loader, or all interlock switch
 Ex1a9    Cassete carrier was removed. Please set cassette carrier
 Ex1aa    The door of the cassette part is open
 Ex1ab    Maintenance-cover of Auto-loader was opend. Please clode maintenance cover
 Ex1ac    Bridge cover-2 was opened. Please clode bridge cover-2
 Ex1ad    An interleaf under a plate was detected. Or a plate size (in the Y direction) is shorter than the set value
 Ex1ae    An interleaf was detected on a plate. Or a plate size (in the Y direction) is shorter than the set value
 Ex1b0    Trail clamp is not detected on the clamp arm before the plate loading
 Ex1b1    Trail clamp is detected on the clamp arm before the plate unloading
 Ex1b2    Trail clamp cannot be set correctly
 Ex1b3    This plate can’t be transed. Because something error has occured when the transfering to AT
 Ex1b4    This plate can’t be transed. Because trans path position is down
 Ex1b6    The bridge-passing sensor does not turn OFF (for Jig mode)
 Ex1b7    A plate remains on the plate detection sensor(PH70)
 Ex1b8    When detects the front of a plate, the detection area is not brought
 Ex1b9    When detects the front of a plate, the detection of Home or Away is not brought
 Ex1ba    PH11-2H-sensor is illegal. The PH11-2H-sensor does not turn ON during initialization
 Ex1bb    PH11-2A-sensor is illegal. The PH11-2A-sensor does not turn ON during initialization
 Ex1c0    Lead clamp release bar cannot be driven. Either PH30H or PH31H is illegal
 Ex1c1    Lead clamp release bar cannot be driven. Either PH30H or PH31H is illegal
 Ex1c2    Trans path cannot be driven. Either PH55, PH56, or PH57 is illegal
 Ex1c3    Trans path cannot be driven. Either PH56, or, PH57 is illegal
 Ex1c4    Trans path cannot be driven. Either PH55, or, PH56 is illegal
 Ex1c5    Trans path cannot be driven. Either PH55, or, PH57 is illegal
 Ex1c6    Trail clamp arm cannot be driven. Either PH20 or PH21 is illegal
 Ex1c7    Trail clamp arm cannot be driven. Either PH20 or M20 is illegal
 Ex1c8    An interleaf was detected under a plate
 Ex1c9    When centering alignment is performed, the plate set position is out of range
 Ex1ca    Error has occured on the punching unit. The punch hole could not be opened correctly
 Ex1cb    Opened shutter obstructs trans path driving
 Ex1cc    Trail clamp arm obstructs trans path driving
 Ex1cd    A plate remains in a machine
 Ex1d0    Transfer operation is halted with an abort command
 Ex1d1    Transport tasks are being processed
 Ex1d2    Transport tasks are not being processed
 Ex1d3    Transport tasks: Message order error
 Ex1d4    Transport system is not initialized
 Ex1e0    SVC user parameter breakdown
 Ex1e1    SVC user parameter setting error
 Ex1e2    SVC over-current
 Ex1e3    SVC detection of regenerative error
 Ex1e4    SVC postion error pulse overflow
 Ex1e5    SVC Main circuit voltage error detection
 Ex1e6    SVC over speed
 Ex1e7    SVC overloaded (high load)
 Ex1e8    SVC overloaded (low load)
 Ex1e9    SVC stauts 99h
 Ex1ea    SVC heat sink has overheated
 Ex1eb    SVC stauts b1h
 Ex1ec    SVC is out of control
 Ex1ed    SVC phase error has been detected in the encoder
 Ex1ef    SVC A and B phase for the encoder has broke down
 Ex1f0    SVC C phase for the encoder has broke down
 Ex1f1    SVC some phases of power line is open
 Ex1f3    SVC An instantaneous loss of power has occurred
 Ex1f4    SVC unknown error
 Ex200    Exposure operation is interrupted with an abort command
 Ex201    Exposure processing task is now processing another command
 Ex202    Cancellation was requested while processing was not being performed
 Ex203    PGON is not asserted
 Ex204    START signal is not asserted
 Ex205    START signal is not negated
 Ex206    Test pattern; Data is not transferred
 Ex207    Test pattern; Data transfer is not completed
 Ex208    Reset procedure for RB31 board is not completed
 Ex209    The set value for the drum rotation speed is too large
 Ex20a    No plate edge is detected (when the plate edge sensor moves to the Away side)
 Ex20b    No plate edge is detected (when the plate edge sensor is returning to the Home side)
 Ex20c    Recording head has traveled beyond the limit (on the Away side)
 Ex20d    Recording head has traveled beyond the limit (on the Home side)
 Ex20e    Recording head positioning range error
 Ex20f    Recording head has not been positioned at its origin. (Origin sensor does not turn OFF)
 Ex210    Recording head has not been positioned at its origin. (Origin sensor does not turn ON)
 Ex211    Emergency stop is requested for the secondary-scanning motor
 Ex212    Secondary-scanning motor is deactivated with an abort command
 Ex213    Secondary scanning motor is illegal
 Ex214    Exposure in the secondary scanning direction exceeds the effective image ouput range
 Ex215    FPGA sequence error
 Ex216    Time-out error has occurred when the secondary scanning motor is activated
 Ex217    EZ search has not detected the ORG sensor
 Ex218    EZ search has not detected the EZ sensor
 Ex219    When the CAL sensor search was executed, the maximum light intensity was less than 50 mW
 Ex21a    Light intensity at the measurement starting point was at maximum when the CAL sensor search was executed
 Ex21b    Light intensity at the measurement end point was at maximum when the CAL sensor search was executed
 Ex21c    Over travel at recording head’s Home side when the CAL sensor search was executed
 Ex21d    Test pattern parameter error
 Ex21e    PGON signal is not negated
 Ex21f    Secorndary direction origin point setup procedure failure.(The calibrated origin point is not the same as logical origin point)
 Ex220    After an image data transfer from RIP is interrupted, it isn’t resumed
 Ex221    Drum rotation error was detected. This plate will be unloaded because it could not be exposed correctly
 Ex300    Both of plate pad and paper pad are not in original point
 Ex301    After an interleaf is removed, plate cannot be detected
 Ex302    An interleaf was detected on a plate. Or a plate size (in the Y direction) is shorter than the set value
 Ex303    Plate pad cannot be initialized
 Ex304    Plate pad cannot carry a plate
 Ex305    While carring a plate, the plate pad dropped the plate
 Ex306    Paper pad cannot be initialized
 Ex307    Air pressure in the plate pad does not go down
 Ex308    Air pressure in the paper pad does not go down
 Ex309    PCL time-out error has occurred when plate pad was moved
 Ex30a    PCL time-out error has occurred when paper pad was moved
 Ex30b    Time-out error has occurred when plate pad was moved by stepping
 Ex30c    Time-out error has occurred when paper pad was moved by stepping
 Ex30d    A plate cannot be carried into the transport unit
 Ex30e    PH90 does not switch to ON while removing the interleaf
 Ex30f    PH90 does not switch to OFF while removing the interleaf
 Ex310    Maintenance cover of auto-loader is open. Please close maintenance cover
 Ex311    Bridge cover-2 of auto-loader is open. Please close bridge cover-2
 Ex312    Cassette carrier is not set. Please set cassette carrier
 Ex313    A plate remains in the bridge unit
 Ex314    An interleaf remains in the paper exit
 Ex315    Nip roller does not ascend
 Ex316    Nip roller does not descend
 Ex317    Auto-loader is not turned on, or some interlock switches on Auto-loader are OFF. Please turn on Auto-loader, or all interlock switch
 Ex318    A plate cannot be carried to the bridge-passing sensor
 Ex319    The plate pad went down from the original point
 Ex31a    The paper pad went down from the original point
 Ex31b    Maintenance-cover of Auto-loader was opend. Please clode maintenance cover
 Ex31c    Bridge cover-2 was opened. Please clode bridge cover-2
 Ex31d    Door was opened. Please close the door
 Ex31e    Cassete carrier was removed. Please set cassette carrier
 Ex31f    The paper pad dropped the interleaf while carrying the it
 Ex320    Plate pad dropped a plate before the plate pad reached the intermediate sensor
 Ex321    An interleaf in front of a plate was detected
 Ex322    A plate remains on the sensor-2 of the bridge
 Ex323    Intermediate sensor is OFF
 Ex324    Power switch was turned off while Auto-loader was moving
 Ex325    A plate cannot be carried to the intermediate sensor
 Ex326    An interleaf under a plate was detected. Or a plate size (in the Y direction) is shorter than the set value
 Ex327    The bridge-passing sensor does not turn OFF (for Jig mode)
 Ex328    Door is open
 Ex32c    The nip-roller for paper discharge cann’t be opened
 Ex340    Door is open
 Ex341    The interlock switch-3 is OFF
 Ex342    The interlock switch-2 is OFF
 Ex343    The interlock switch-1 is OFF
 Ex344    A fuse on the relay board at home side has blown
 Ex345    A fuse on the relay board at away side has blown
 Ex346    Nip roller does not descend
 Ex347    Nip roller does not ascend
 Ex348    Shutter does not open
 Ex349    Shutter does not close
 Ex360    A plate remains on the bridge’s sensor-1
 Ex361    No plate exists on the bridge’s sensor-3
 Ex362    A plate remains on the bridge’s sensor-3
 Ex363    A plate size in the Y direction is too long when its transferring to the AT
 Ex364    A plate size in the Y direction is too short when its transferring to the AT. Or an interleaf in front of a plate was detected
 Ex365    After the paper pad is descended, the metal sensor does not switch to ON
 Ex366    Plate pad dropped the plate, before this initialize
 Ex367    A teaching of plate size in the Y direction (1st) is finished
 Ex368    A teaching of plate size in the Y direction (2nd) is finished
 Ex369    This plate can’t be transed. Because something error has occured when transfering to AT
 Ex36a    Air pressure in the plate pad does not go down after retry
 Ex36b    A plate remains on the insertion table in the transport unit
 Ex36c    This plate is judge as a paper during judgement operation
 Ex36d    This plate can’t be transed. Because trans path position is down
 Ex380    The door of the cassette part is open
 Ex381    Time-out error has occurred when lift was initialized
 Ex382    Time-out error has occurred when lift was moved
 Ex383    Though the lift was initialized, the origin sensor is not ON
 Ex384    The lift is not in the position where it is specified
 Ex385    Already, there has been a cassette on the lift
 Ex386    There are some cassettes which aren’t being set properly
 Ex387    MA-L can’t be initialized because some cassettes are not in the lift or the cassette properly
 Ex388    There is no cassette in the specified cassette slot
 Ex389    There is no cassette on the lift
 Ex38a    Lift has traveled beyond the limit (on the Up side)
 Ex38b    Lift has traveled beyond the limit (on the Down side)
 Ex38d    A cassette is already in the place to return a cassette
 Ex38e    A lift can’t be raised and lowered because some cassettes are not in the lift or the cassette properly
 Ex38f    Time-out error has occurred when a cassette was moved to cassette part
 Ex390    Time-out error has occurred when a cassette was moved to lift
 Ex391    Either plate pad or paper pad is not in original point
 Ex392    An ineffective cassette number was indicated
 Ex393    Cassette has traveled beyond the limit (on the Lift side)
 Ex394    Cassette has traveled beyond the limit (on the Cassette side)
 Ex395    MA-L can’t be initialized because some cassettes can’t be returned to the origin
 Ex396    Though there is a cassette on the lift, the place to return the cassette isn’t vacant
 Ex397    Though the movement of the lift was finished, the lift position sensor at the target position is not on
 Ex398    MA-L Servo alarm
 Ex399    Time-out error has occurred when arm was moved
 Ex39a    Time-out error has occurred when a cassette was moved to cassette part by arm
 Ex39b    Arm jut-out sensor (LS210E) is off
 Ex39c    A cassette is in illegal position of the cassette slot
 Ex39d    Arm is not in original point
 Ex39e    SQ210A sensor is illegal
 Ex400    Plate has already been loaded
 Ex401    Plate has not been loaded
 Ex402    Door is open
 Ex403    Dump interleaves from the collection box
 Ex600    Either the conveyor, processor, or stocker is not turned on, or is in the busy status or error status
 Ex601    Either the conveyor, processor, or stocker is not turned on, or is in the busy status or error status
 Ex602    The plate cannot be transferred into the AT unit
 Ex603    The plate cannot be transferred completely into the AT unit
 Ex606    Error
 Ex607    Busy
 Ex608    Error
 Ex609    Busy
 Ex60a    Error
 Ex60b    Busy
 Ex60c    Error occurred in ATM while a plate was carried to ATM
 Ex80c    The result of the calculation “Initial value + increment value * (repetition – 1)” exceeds the upper limit value
 Ex80d    (The result of the calculation “Exposure starting point + (pattern width + gap) * (repetition – 1)” exceeds the plate size
 Ex80e    The specified plate is not linked with the printing-machine’s data
 Ex80f    Perform initialization at the service screen
 Ex810    No plate is set at inlet of transport unit
 Ex811    Plate (printer) size specified by the host computer is not registered
 Ex812    Image size specified by host computer is larger than allowable output image size
 Ex813    Current offset of printing machine settings cause image to extend off plate
 Ex814    Current paper-position of printing machine settings cause image to extend outside of allowable exposure area
 Ex816    Some LD is nearing the end of its usable life
 Ex817    There are some punch blocks, which have been used for more than the endurance time
 Ex819    It failed to read the cassette number. It considers that the cassette number is No.1
 Ex81a    Some LD’s cannot be calibrated to the target power. These LD’s be calibrated to lower target power
 Ex81b    Some LD’s cannot be calibrated to the target power. Temporary to work half channels of recording head
 Ex81c    Some LD’s cannot exposed by setting power due to be calibrated to lower target power
 Ex81d    The temperature of the environment is greater than 28degrees
 Ex81e    The temperature of the environment is less than 18degrees
 Ex81f    Sensor for the temperature of the environment has not been connected
 Ex820    Trail clamps are nearing the end of its usable life
 Ex821    Trail clamps have been used for more than the endurance time
 Ex822    Backup/restore of the data on NVRAM can’t be performed, because the Dip-Sw 2 is not on
 Ex823    The backup of the data on NVRAM is not in Flash-Memory
 Ex824    Calibration must be done because there is some LD which doesn’t reach the target power. But, LD calibration can not processed because temperature of LD block is too low
 Ex825    The direction where a connected conveyer can’t be changed is set up in the plate types setting
 Ex826    No response was returned from the conveyor
 Ex827    An error was returned from the conveyer toward the switching command
 Ex828    The conveyer can’t be changed to the direction that is set up in the plate types setting
 Ex82a    Since the light intensity of laser diodes is detected as having deviated more than +-5% from the specified value, the equipment executes the calibration
 Ex82b    Communication with the RAS server was interrupted. (RAS server was turned off, or RS-232C cable was drawn out)
 Ex82c    No response come from DNS
 Ex82d    Communication with the RAS server has resume
 Ex82e    It failed in the connection to the rotating light server
 Ex82f    The name of the mail server isn’t right
 Ex830    It failed in the connection to the mail server
 Ex831    Mail account was rejected
 Ex832    An error occurred in the transmission of DATA command
 Ex833    An error occurred in the transmission of header
 Ex834    An error occurred in the transmission of body
 Ex835    An error occurred in the transmission of attached file
 Ex836    An error occurred in the transmission of TO command
 Ex837    A command was sent to the SMTP server. But, no answer was returned from the server
 Ex839    The cable between RB31 board and recording head is disconnected
 Ex880    Servo pack: Time-out error occurred while receiving data
 Ex881    Servo-Pack:Address error
 Ex882    Servo-Pack:Data error
 Ex883    Servo-Pack:Check sum error
 Ex884    Servo-Pack:Undefined error code
 Ex885    Servo-Pack:Number of received characters are insufficient
 Exe01    Excessive current in the LD drive (driver 1 board)
 Exe02    Excessive current in the LD drive (driver 2 board)
 Exe03    Excessive current in the LD drive (driver 3 board)
 Exe04    Excessive current in the LD drive (driver 4 board)
 Exe05    Driver board temperature error or Head FPGA Version Error
 Exe06    -5 V power supply error
 Exe07    Calibration sensor is not connected
 Exe08    Offset error in the calibration sensor
 Exe09    Irregular 5 V power supply
 Exe0a    Irregular +15 V power supply
 Exe0b    Irregular -15 V power supply
 Exe0c    Irregular 24 V power supply
 Exe0d    Cover switch is OFF
 Exe0e    BL command error (counter value is 0)
 Exe0f    Zoom sensor is not detecting
 Exe10    Focus sensor is not detecting
 Exe11    Time has expired for home return.(Zoom or focus motor)
 Exe12    Power supply irregular while the motor is driving
 Exe13    Pulse motor has traveled beyond the limit. (Zoom or focus motor)
 Exe14    Irregular power supply(instantaneous loss)
 Exe20    Temperature of the LD block is greater than 28degrees
 Exe21    Temperature at the periphery of the optical unit is greater than 35degrees
 Exe22    Temperature of the radiating fin of the Peltier element is greater than 55 degrees
 Exe23    Dew condensation error
 Exe24    Sensor for LD block has not been connected
 Exe25    Sensor for the periphery of the optical unit has not been connected
 Exe26    Sensor for the radiating fin of the Peltier element has not been connected
 Exe27    The dew condensation detection sensor has not been connected
 Exe28    Temperature of the LD block is low
 Exe30    Power supply error occurred when the recording head received the DW command
 Exe31    Command error occurred when the recording head received the DW command
 Exe32    Download error occurred when the recording head received the DP command
 Exe33    Download error occurred when the recording head received the DP command
 Exe34    Download address error occurred
 Exe35    Error occurred when the recording head received the BU command
 Exe36    Error occurred when the recording head received the BD command
 Exe40    Writing error occurred when the recording head received the AC command
 Exe41    Writing error on EEPROM
 Exe42    RAM error
 Exe43    ROM check sum error
 Exe44    FPGA error
 Exe45    Data error due to a divide-by-zero error
 Exe60    LD Current setting Error
 Exe61    The temperature of the LD block is greater than 28degrees
 (Temperature at the periphery of the optical unit > 35degrees. Temperature of the environment <= 28degrees)”
 Exe62    The temperature of the LD block is greater than 28degrees (Temperature at the periphery of the optical unit <= 35degrees. Temperature of the environment > 28degrees)”
 Exe63    The temperature of the LD block is greater than 28degrees
 (Temperature at the periphery of the optical unit <= 35degrees. Temperature of the environment > 28degrees)”
 Exe64    The temperature at the periphery of the optical unit is greater than 35degrees
 (Temperature of the environment <= 28degrees)
 Exe65    The temperature of the radiating fin is greater than 55degrees
 (Temperature at the periphery of the optical unit>35degrees. Temperature of the environment <= 28degrees)
 Exe66    The temperature of the radiating fin is greater than 55degrees
 (Temperature at the periphery of the optical unit <= 35degrees)
 Exe67    The LD block has dew. (Temperature of the LD block < 22degrees
 Temperature at the periphery of the optical unit >= 18degrees)
 Exe68    The LD block has dew. (Temperature of the LD block < 22degrees
 Temperature at the periphery of the optical unit < 18degrees)
 Exe69    The temperature of the LD block is less than 5degrees
 (Temperature at the periphery of the optical unit >= 17degrees)
 Exe6a    The temperature of the LD block is less than 5degrees
 (Temperature at the periphery of the optical unit < 17degrees. Temperature of the environment >= 18degrees)
 Exe6b    The temperature of the LD block is greater than 28degrees 
 (Temperature at the periphery of the optical unit > 35degrees. Temperature of the environment <= 28degrees)
 Exe6c    The temperature of the LD block is greater than 28degrees
 (Temperature at the periphery of the optical unit <= 35degrees. Temperature of the environment > 28degrees)
 Exe6d    The temperature of the LD block is greater than 28degrees
 (Temperature at the periphery of the optical unit <= 35degrees. Temperature of the environment <= 28degrees)
 Exe6e    The temperature inside the machine is greater than 35degrees
 (Temperature of the environment <= 28degrees)
 Exe6f    The temperature of the radiating fin is greater than 55degrees
 (Temperature at the periphery of the optical unit>35degrees. Temperature of the environment <= 28degrees)
 Exe70    The temperature of the radiating fin is greater than 55degrees
 (Temperature at the periphery of the optical unit <= 35degrees.)
 Exe71    It is just before a recording head has dew
 (Temperature of the LD block < 22degrees. Temperature of the environment >=18degrees)
 Exe72    It is just before a recording head has dew
 (Temperature of the LD block < 22degrees. Temperature of the environment < 18degrees)
 Exe73    The temperature of the LD block is in between 5degrees and 17degrees
 (Temperature of the environment <= 18degrees)
 Exe74    The temperature of the LD block is in between 5degrees and 17degrees
 (Temperature of the environment < 18degrees.)
 Exea0    Light intensity adjustment error 0ch
 Exea1    Light intensity adjustment error 1ch
 Exea2    Light intensity adjustment error 2ch
 Exea3    Light intensity adjustment error 3ch
 Exea4    Light intensity adjustment error 4ch
 Exea5    Light intensity adjustment error 5ch
 Exea6    Light intensity adjustment error 6ch
 Exea7    Light intensity adjustment error 7ch
 Exea8    Light intensity adjustment error 8ch
 Exea9    Light intensity adjustment error 9ch
 Exeaa    Light intensity adjustment error 10ch
 Exeab    Light intensity adjustment error 11ch
 Exeac    Light intensity adjustment error 12ch
 Exead    Light intensity adjustment error 13ch
 Exeae    Light intensity adjustment error 14ch
 Exeaf    Light intensity adjustment error 15ch
 Exeb0    Light intensity adjustment error 16ch
 Exeb1    Light intensity adjustment error 17ch
 Exeb2    Light intensity adjustment error 18ch
 Exeb3    Light intensity adjustment error 19ch
 Exeb4    Light intensity adjustment error 20ch
 Exeb5    Light intensity adjustment error 21ch
 Exeb6    Light intensity adjustment error 22ch
 Exeb7    Light intensity adjustment error 23ch
 Exeb8    Light intensity adjustment error 24ch
 Exeb9    Light intensity adjustment error 25ch
 Exeba    Light intensity adjustment error 26ch
 Exebb    Light intensity adjustment error 27ch
 Exebc    Light intensity adjustment error 28ch
 Exebd    Light intensity adjustment error 29ch
 Exebe    Light intensity adjustment error 30ch
 Exebf    Light intensity adjustment error 31ch
 Exee0    Incorrect command has been input
 Exee1    The temperature of the LD block is greater than 28degrees
 (Temperature at the periphery of the optical unit > 35degrees. Temperature of the environment > 28degrees)
 Exee2    Temperature at the periphery of the optical unit is greater than 35degrees
 (Temperature of the environment > 28degrees)
 Exee3    The temperature of the radiating fin is greater than 55degrees
 (Temperature at the periphery of the optical unit > 35degrees. Temperature of the environment > 28degrees)
 Exee4    It is just before a recording head has dew
 (Temperature of the LD block >= 22degrees)
 Exee5    The temperature of the LD block is less than 5degrees
 (Temperature at the periphery of the optical unit < 17degrees. Temperature of the environment < 18degrees)
 Exee6    0-7ch in signal line is break detect
 Exee7    8-15ch in signal line is break detect
 Exee8    0-15ch in signal line or DOTCLK signal line is break detect
 Exef0    Recording head processing task is now processing another message
 Exef2    Recording head unit is not running
 Exef3    Recording head data check sum error occurred when data was uploaded
 Exef4    Recording head data address error occurred when data was uploaded
 Exef5    LD calibration cannot process because temperature of LD block is too low
 Exef6    A command was sent to the exposure head. But, no answer was returned from the exposure head
 Exfa0    System error (stack overflow)
 Exfa1    Floating point arithmetic error
 Exfa2    Divide-by-zero error
 Exfa3    System error (semaphore)
 Exfb0    Flash memory erase error
 Exfb1    Flash memory erase error (during verification)
 Exfb2    Flash memory write error
 Exfb3    Incompatible flash memory

Topsetter 102 screen pt r8xxx

Error:            Description:
 Ex101
 Nip roller does not ascend
 Ex102  Nip roller does not descend
 Ex103  Transport unit does not ascend
 Ex104  Transport unit does not descend
 Ex105  Trail clamp arm does not ascend
 Ex106  Trail clamp arm does not descend
 Ex107  Squeeze roller does not descend
 Ex108  Squeeze roller does not ascend
 Ex109  Trail clamp cannot be locked
 Ex10a  Trail clamp cannot be unlocked
 Ex10b  Balancer drive pin cannot be initialized
 Ex10c  Both of the Home and Away side drive pins for the balancer can not be pulled out
 Ex10d  Both of the Home and Away side drive pins for the balancer can not be inserted
 Ex110  Shutter does not open
 Ex111  Shutter does not close
 Ex112  Plate size (in the Y direction) is shorter than the set value
 Ex113  When the plate is unloaded, the plate pass sensor (PH54-2) does not switch to ON
 Ex114  Not bring down squeeze at loading
 Ex115  Plate size (in the Y direction) is longer than the set value
 Ex116  Servo status is illegal
 Ex117  Servo status is error
 Ex118  Servo alarm
 Ex11a  Drum speed is set beyond the permitted rate of the servo controller
 Ex11b  Current drum’s encoder pulse is beyond 4000
 Ex11c  Error has occurred during drum positioning
 Ex11d  When the clamp is locked, some tail clamps are detected on the clamp arm, or when the clamp is unlocked, some tail clamps are not detected on the clamp arm
 Ex11e  Drum’s encoder pulse is beyond the permitted range after drum positioning
 Ex11f  Plate cannot be transferred into the transport unit
 Ex120  Balancer pin cannot be detected before inserted (Home side)
 Ex121  Balancer pin cannot be detected before pulled out (the balancer is not moving) (Home side)
 Ex122  Clamp arm and squeeze roller do not descend
 Ex123  Clamp arm and squeeze roller do not ascend
 Ex126  There was no plate to move to the shutter
 Ex127  Servo controller does not enter the “Ready” status
 Ex128  No balancer has been detected by the balancer search sensor
 Ex129  Error has occurred on the Home side of the alignment plate (while the alignment plate is returning to its origin)
 Ex12a  Error has occurred on the Away side of the alignment plate (while the alignment plate is returning to its origin)
 Ex12b  Error has occurred on the Home and Away sides of the alignment plate (while the alignment plate is returning to its origin)
 Ex12c  Error has occurred on the Home side of the alignment plate (while alignment is performed)
 Ex12d  Error has occurred on the alignment plate (while alignment is performed)
 Ex12e  Error has occurred on the Home and Away sides of the alignment plate (when alignment is performed)
 Ex12f  Plate has not transferred to the punch unit
 Ex139  After a plate is transferred to the gripper clamp, the plate detection sensor (PH25H/A) does not switch to ON
 Ex13a  When the clamp arm is lowered, the sensor (to detect whether the clamp arm pins are hooked on the clamp properly) has been turned
 Ex13b  The specified encoder pulse for the drum is beyond 4000
 Ex13c  The transport unit’s Away side is not moving during its operation
 Ex13d  The transport unit’s Home side is not moving during its operation
 Ex13e  Error has occurred on the Home side of the alignment plate (while the alignment plate is finely returning to its origin)
 Ex13f  Error has occurred on the Away side of the alignment plate (while the alignment plate is finely returning to its origin)
 Ex140  Error has occurred on the Home and Away side of the alignment plate (while the alignment plate is returning to its origin)
 Ex141  A plate remains in the transport unit when the machine received a request command
 Ex142  A plate remains in the transport unit during error handling
 Ex143  A plate remains on the discharge table in the transport unit
 Ex144  A plate remains on the insertion table in the transport unit
 Ex145  Plate cannot be moved onto the discharge table during initialization
 Ex146  Plate cannot be moved onto the insertion table
 Ex147  Balancer search operation has not been completed properly
 Ex148  When the transport unit descends, only the Home side Down sensor in the transport unit is turned ON
 Ex149  When the transport unit descends, only the Away side Down sensor in the transport unit is turned ON
 Ex14a  When the transport unit ascends, only the Home side UP sensor in the transport unit is turned ON
 Ex14b  When the transport unit ascends, only the Away side UP sensor in the transport unit is turned ON
 Ex14c  Front, rear or side cover is open. (Some interlock switches are OFF)
 Ex14d  A fuse on the relay board was blown. (home)
 Ex14e  Thumbscrew is not tightened securely on the rear cover. (The servo stop switch is OFF)
 Ex14f  A plate exists on the discharge table in the transport unit during initialization
 Ex150  A plate exists on the insertion table in the transport unit during initialization
 Ex151  Number of balancers is not sufficient. (The number of balancers checked by the balancer search sensor was one, two or three for both the Home and Away sides)
 Ex152  Clamp arm is not in the UP position
 Ex153  A fuse on the relay board was blown. (away)
 Ex154  Blower is turned off, but signal does not change
 Ex155  Tail clamps are missing during initialization
 Ex156  The size check program of the cetering function detects that the measured plate size is longer than the expected one
 Ex157  The size check program of the cetering function detects that the measured plate size is shorter than the expected one
 Ex158  Both of Home and Away size check sensors are on before starting the centering program
 Ex159  Auto-loader is stopped by a interlock OFF
 Ex15a  The drum is rotated to “balance pin before inserted”, but status of Servo controller (SVC) is not changed to “Ready”.[away]
 Ex15b  The drum is rotated to “balance pin after inserted”, but status of Servo controller (SVC) is not changed to “Ready”.[away]
 Ex15d  During plate loading, double plate loading is detected
 Ex15e  The loaded plate is floating from the drum is detected during drum spinning
 Ex15f  The drum can not be spined up because the Away-Upper sensor of the clamp arm is off
 Ex160  The drum can not be spined up because the Home-Upper sensor of the clamp arm is off
 Ex161  The drum can not be spined up because the balancing pin (Away side) is not in the waiting position
 Ex162  The drum can not be spined up because the balancing pin (Home side) is not in the waiting position
 Ex163  The drum can not be spined up because the Upper sensor of the squeeze roller is off
 Ex165  The drum is rotated to the “lead clamp position”, but the status of the Servo controller (SVC) has not changed to “Ready”
 Ex166  The drum is rotated to the “tail clamp position”, but the status of the Servo controller (SVC) has not changed to “Ready”
 Ex167  The drum is rotated to the “squeeze position”, but the status of the Servo controller (SVC) has not changed to “Ready”
 Ex168  The drum is rotated to the “balance pin before inserted”, but the status of the Servo controller (SVC) has not changed to “Ready”
 Ex169  The drum is rotated to the “balance pin after inserted”, but the status of the Servo controller (SVC) has not changed to “Ready”
 Ex16a  The drum is rotated to the “pick up tail clamp position”, but the status of Servo controller (SVC) has not changed to “Ready”
 Ex16b  The drum is rotated to the “plate removal position”, but the status of the Servo controller (SVC) has not changed to “Ready”
 Ex16c  SVC Error has occurred during drum positioning for the lead clamp
 Ex16d  SVC Error has occurred during drum positioning for the tail clamp
 Ex16e  SVC Error has occurred during drum positioning for the squeeze
 Ex16f  SVC Error has occurred during drum positioning for the balance pin insertion
 Ex170  SVC Error has occurred during drum positioning for the balance pin pull out
 Ex171  SVC Error has occurred during drum positioning for the picking up tail clamp
 Ex172  SVC Error has occurred during drum positioning for the plate removal
 Ex173  Time-out error has occurred during drum positioning (Lead clamp position)
 Ex174  Time-out error has occurred during drum positioning (Tail clamp position)
 Ex175  Time-out error has occurred during drum positioning (Squeeze position)
 Ex176  Time-out error has occurred during drum positioning (Balance pin before inserted)
 Ex177  Time-out error has occurred during drum positioning (Balance pin after inserted) (Home)
 Ex178  Time-out error has occurred during drum positioning (Pick up tail clamp)
 Ex179  Time-out error has occurred during drum positioning (Plate removal)
 Ex17a  After verifying the removal of the plate, press the OK button. When the OK button is pressed, initialization begins
 Ex17b  PH62A-sensor is illegal. The sensor detects a plate during initialization
 Ex17c  PH25H-sensor is illegal. The sensor detects a plate during plate loading
 Ex17d  Time-out error has occurred during drum positioning.(balance pin before inserted) (Away)
 Ex17e  Time-out error has occurred during drum positioning.(balance pin after inserted) (Away)
 Ex180  Drum does not start rotating at high-speed
 Ex181  Drum does not rotate at the specified high-speed
 Ex182  Error has occurred after the drum rotated at the specified high-speed
 Ex183  Drum cannot be stopped when rotating at high-speed
 Ex184  Drum operation is halted with an emergency stop command
 Ex185  Drum operation is stopped with an abort command
 Ex186  Drum’s vacuum pressure is not sufficient
 Ex187  Error has occurred on the blower or the power supply of the blower is OFF
 Ex188  Drum operation is halted due to low pressure in the drum
 Ex189  Door is open
 Ex18a  Door does not open
 Ex18b  Transport tasks: Parameter error
 Ex18c  Error has occured on the blower. Please turn off this machine, and turn on after waiting 10 seconds. Also, confirm whether or not the connector doesn’t come off
 Ex18d  The drum can not be spun up, because some of the interlock switches are OFF, or some of the actuator’s sensors are damaged, or the blower is damaged
 Ex18e  Door does not open, because some of the interlock switches are OFF (front cover or rear cover is open)
 Ex190  Clamp arm does not descend (Home side)
 Ex191  Clamp arm does not descend (Away side)
 Ex192  Clamp arm does not ascend (Home side)
 Ex193  Clamp arm does not ascend (Away side)
 Ex194  When the clamp arm is lowered, the sensor (to detect whether the clamp arm pins are hooked on the clamp properly) has been turned ON (Away side)
 Ex195  Trail clamp cannot be locked (Home side)
 Ex196  Trail clamp cannot be locked (Away side)
 Ex197  Trail clamp cannot be unlocked (Home side)
 Ex198  Trail clamp cannot be unlocked (Away side)
 Ex199  Balancer drive pin cannot be inserted (Home side)
 Ex19a  Balancer drive pin cannot be inserted (Away side)
 Ex19b  Balancer drive pin cannot be pulled out (Home side)
 Ex19c  Balancer drive pin cannot be pulled out (Away side)
 Ex19d  Balancer pin cannot be detected before insertion (Away side)
 Ex19e  Balancer pin cannot be detected before pull out (the balancer is not moving) (Away side)
 Ex19f  No balancer has been detected by the balancer search sensor (Home side)
 Ex1a0  No balancer has been detected by the balancer search sensor (Away side)
 Ex1a1  Number of balancers is not sufficient. (Home side)
 Ex1a2  Number of balancers is not sufficient. (Away side)
 Ex1a3  Rear cover is open (Some interlock switch are OFF)
 Ex1a4  Away side cover is open (Some interlock switch are OFF)
 Ex1a5  Front cover is open (Some interlock switch are OFF)
 Ex1a6  A plate cannot be carried into the transport unit
 Ex1a7  A plate cannot be carried to sensor PPH50-2
 Ex1a8  Auto-loader is not turned on, or some interlock switches on Auto-loader are OFF
 Ex1a9  Cassete carrier was removed
 Ex1aa  The door of the cassette part is open
 Ex1ab  Rear-cover of Auto-loader was opend
 Ex1ac  Top cover was opened
 Ex1ad  A slipping paper under a plate was detected. Or a plate size (in the Y direction) is shorter than the set value
 Ex1ae  A slipping paper on a plate was detected. Or a plate size (in the Y direction) is shorter than the set value
 Ex1b0  Time-out error has occurred when Punch 1 is activated
 Ex1b1  Time-out error has occurred when Punch 2 is activated
 Ex1b2  Time-out error has occurred when Punch 3 is activated
 Ex1b3  Time-out error has occurred when Punch 4 is activated
 Ex1b4  Time-out error has occurred when Punch 5 is activated
 Ex1b5  Time-out error has occurred when Punch 6 is activated
 Ex1b6  Time-out error has occurred when Punch 7 is activated
 Ex1b7  Time-out error has occurred when Punch 8 is activated
 Ex1b8  Time-out error has occurred when Punch 9 is activated
 Ex1b9  Time-out error has occurred when Punch A is activated
 Ex1ba  Time-out error has occurred when Punch B is activated
 Ex1bb  Time-out error has occurred when Punch C is activated
 Ex1bc  Nip roller(Unload) does not ascend
 Ex1bd  Nip roller(Unload) does not descend
 Ex1be  Unload path does not ascend
 Ex1bf  Unload path does not descend
 Ex1c0  Time-out error has occurred when the caterpillar motor is activated
 Ex1c1  Error has occurred on the caterpillar motor (while the alignment plate is finely returning to its origin)
 Ex1c2  Door does not open
 Ex1c3  Door does not close
 Ex1c7  Plate is not transferred to the punch unit [PH59]
 Ex1c8  After a plate is transferred to the gripper clamp, the plate detection sensor (PH25H/A) does not switch to ON [PH59]
 Ex1c9  When the transport unit descends, plate cannot be transferred into the transport unit
 Ex1ca  When the plate is unloaded, PH53-sensor does not switch to ON
 Ex1cb  Opened shutter obstructs trans path driving
 Ex1cc  Trail clamp arm obstructs trans path driving
 Ex1cd  A plate remains in a machine
 Ex1d0  Transfer operation is halted with an abort command
 Ex1d1  Transport tasks are being processed
 Ex1d2  Transport tasks are not being processed
 Ex1d3  Transport tasks: Message order error
 Ex1d4  Transport system is not initialized
 Ex1e0  SVC User constant breakdown
 Ex1e1  SVC User constant setting error
 Ex1e2  SVC over-current
 Ex1e3  SVC detection of regenerative error
 Ex1e4  SVC postion error pulse overflow
 Ex1e5  SVC Main circuit voltage error detection
 Ex1e6  SVC over speed
 Ex1e7  SVC overloaded (high load)
 Ex1e8  SVC overloaded (low load)
 Ex1e9  SVC stauts 99h
 Ex1ea  SVC heat sink has overheated
 Ex1eb  SVC stauts b1h
 Ex1ec  SVC is out of control
 Ex1ed  SVC phase error has been detected in the encoder
 Ex1ef  SVC A and B phase for the encoder has broke down
 Ex1f0  SVC C phase for the encoder has broke down
 Ex1f1  SVC Power line Open phase
 Ex1f3  SVC An instantaneous loss of power has occurred
 Ex1f4  SVC unknown error
 Ex1f5   Detection of servo encorder error
 Ex200  Exposure operation is interrupted with an abort command
 Ex201  Exposure processing task is now processing another command
 Ex202  Cancellation requested while processing was not being performed
 Ex203  PGON is not asserted
 Ex204  START signal is not asserted
 Ex205  START signal is not negated
 Ex206  Test pattern; Data is not transferred
 Ex207  Test pattern; Data transfer is not completed
 Ex208  Reset procedure for TB64 board is not completed
 Ex209  The set value for the drum rotation speed is too large
 Ex20a  No plate edge is detected (when the plate edge sensor moves to the Away side)
 Ex20b  No plate edge is detected (when the plate edge sensor is returning to the Home side)
 Ex20c  Recording head has traveled beyond the limit (on the Away side)
 Ex20d  Recording head has traveled beyond the limit (on the Home side)
 Ex20e  Recording head positioning range error
 Ex20f  Recording head has not been positioned at its origin. (Origin sensor does not turn OFF)
 Ex210  Recording head has not been positioned at its origin. (Origin sensor does not turn ON)
 Ex211  Emergency stop is requested for the secondary-scanning motor
 Ex212  Secondary-scanning motor is deactivated with an abort command
 Ex213  Secondary scanning motor is illegal
 Ex214  Exposure in the secondary scanning direction exceeds the effective image ouput range
 Ex215  FPGA sequence error
 Ex216  Time-out error has occurred when the secondary scanning motor is activated
 Ex217  EZ search has not detected the ORG sensor
 Ex218  EZ search has not detected the EZ sensor
 Ex219  When the CAL sensor search was executed, the maximum light intensity was less than 50 mW
 Ex21a  When the CAL sensor search was executed, the light intensity at the measurement starting point was the maximum
 Ex21b  When the CAL sensor search was executed, the light intensity at the measurement end point was the maximum
 Ex21c  CAL sensor search has not detected the over travel limit switch on the recording head’s Home side
 Ex21d  Test pattern parameter error
 Ex21e  PGON signal is not negated
 Ex21f  Secorndary direction origin point setup procedure failure (The calibrated origin point is not the same as logical origin point)
 Ex220  After an image data transfer from RIP is interrupted, it isn’t resumed
 Ex221  Cooling fan for TB64 board is illegal
 Ex222  Hungup was detected
 Ex223  The version of TB64 board and FES board is inharmonious
 Ex224  Machine and firmware is inharmonious
 Ex300  Both of plate pad and paper pad are not in original point
 Ex301  After a slipping paper is removed, plate cannot be detected
 Ex302  A slipping paper on a plate was detected. Or a plate size (in the Y direction) is shorter than the set value
 Ex303  Plate pad cannot be initialized
 Ex304  Plate pad cannot carry a plate
 Ex305  During the carring a plate, plate pad dropped the plate
 Ex306  Paper pad cannot be initialized
 Ex307  Air pressure in the plate pad does not go down
 Ex308  Air pressure in the paper pad does not go down
 Ex309  Time-out error has occurred when plate pad was moved
 Ex30a  Time-out error has occurred when paper pad was moved
 Ex30b  Time-out error has occurred when plate pad was moved intermittently
 Ex30c  Time-out error has occurred when paper pad was moved intermittently
 Ex30e  During the removing a papaer, PH90 does not switch to ON
 Ex30f  During the removing a papaer, PH90 does not switch to OFF
 Ex310  Rear cover of auto-loader is open
 Ex311  Top cover of auto-loader is open
 Ex312  Cassette carrier is not set
 Ex313  A plate remains in the bridge unit
 Ex314  An interleaf remains in the paper exit
 Ex315  Nip roller does not ascend or some interlock switch are illegal, or emergency switch is turned ON
 Ex316  Nip roller does not descend
 Ex317  Auto-loader is not turned on, or all interlock switch are OFF
 Ex318  A plate cannot be carried to the bridge-passing sensor
 Ex319  The plate pad went down from the original point
 Ex31a  The paper pad went down from the original point
 Ex31b  Rear-cover of Auto-loader was opened
 Ex31c  Top cover was opened
 Ex31d  Door was opened
 Ex31e  Cassete carrier was removed
 Ex31f  During the carring a paper, paper pad dropped the paper
 Ex320  Plate pad dropped a plate before the plate pad reached the intermediate sensor
 Ex321  A slipping paper on front of a plate was detected
 Ex322  A slipping paper under front of a plate was detected
 Ex323  Intermediate sensor is OFF
 Ex324  Power switch was turned off while Auto-loader was moving
 Ex325  A plate cannot be carried to the intermediate sensor
 Ex326  A slipping paper under a plate was detected. Or a plate size (in the Y direction) is shorter than the set value
 Ex327  The bridge-passing sensor does not turn OFF (for Jig mode)
 Ex328  Door is open
 Ex32c  The nip-roller for paper discharge cann’t be opened
 Ex340  Door is open
 Ex341  The interlock switch-3 is OFF
 Ex342  The interlock switch-2 is OFF
 Ex343  The interlock switch-1 is OFF
 Ex344  A fuse on the relay board at home side has blown
 Ex345  A fuse on the relay board at away side has blown
 Ex346  Nip roller does not descend
 Ex347  Nip roller does not ascend
 Ex348  Shutter does not open
 Ex349  Shutter does not close
 Ex380  The door of the cassette part is open
 Ex381  Time-out error has occurred when lift was initialized
 Ex382  Time-out error has occurred when lift was moved
 Ex383  Though the lift was initialized, the origin sensor is not ON
 Ex384  The lift is not in the position where it is specified
 Ex385  Already, there has been a cassette on the lift
 Ex386  There are some cassettes which aren’t being set properly
 Ex387  MA-L can’t be initialized because some cassettes are not in the lift or the cassette properly
 Ex388  There is no cassette in the specified cassette slot
 Ex389  There is no cassette on the lift
 Ex38a  Lift has traveled beyond the limit (on the Up side)
 Ex38b  Lift has traveled beyond the limit (on the Down side)
 Ex38d  A cassette is already in the place to return a cassette
 Ex38e  A lift can’t be raised and lowered because some cassettes are not in the lift or the cassette properly
 Ex38f  Time-out error has occurred when a cassette was moved to cassette part
 Ex390  Time-out error has occurred when a cassette was moved to lift
 Ex391  Either plate pad or paper pad is not in original point
 Ex392  An ineffective cassette number was indicated
 Ex393  Cassette has traveled beyond the limit (on the Lift side)
 Ex394  Cassette has traveled beyond the limit (on the Cassette side)
 Ex395  MA-L can’t be initialized because some cassettes can’t be returned to the origin
 Ex396  Though there is a cassette on the lift, the place to return the cassette isn’t vacant
 Ex397  Though the movement of the lift was finished, the lift position sensor at the target position is not on
 Ex398  MA-L Servo alarm
 Ex399  The belt broke
 Ex400  Plate has already been loaded
 Ex401  Plate has not been loaded
 Ex402  Door is open
 Ex403  Dump interleaves from the collection box
 Ex600  Either the conveyor, processor, or stocker is not turned on, or is in the busy status or error status
 Ex601  Either the conveyor, processor, or stocker is not turned on, or is in the busy status or error status
 Ex602  The plate cannot be transferred into the AT unit
 Ex603  The plate cannot be transferred completely into the AT unit
 Ex606  Error
 Ex607  Busy
 Ex608  Error
 Ex609  Busy
 Ex60a  Error
 Ex60b  Busy
 Ex60c  Error occurred in ATM while a plate was carried to ATM
 Ex60d  When the plate is unloaded, the plate pass sensor (PH70) does not switch to ON
 Ex80d  The result of the calculation “Initial value + increment value * (repetition – 1)” exceeds the upper limit value
 Ex80e  (The result of the calculation “Exposure starting point + (pattern width + gap) * (repetition – 1)” exceeds the plate size
 Ex80f  The specified plate is not linked with the printing-machine’s data
 Ex810  Perform initialization at the service screen
 Ex811  No plate is set at inlet of transport unit
 Ex812  Plate (printer) size specified by the host computer is not registered
 Ex813  Image size specified by host computer is larger than allowable output image size
 Ex814  Current offset of printing machine settings cause image to extend off plate
 Ex815  Current paper-position of printing machine settings cause image to extend outside of allowable exposure area
 Ex817  Some LD is nearing the end of its usable life
 Ex818  There are some punch blocks, which have been used for more than the endurance time
 Ex81a  It failed to read the cassette number. It considers that the cassette number is No.1
 Ex81b  Some LD’s cannot be calibrated to the target power
 Ex81c  Some LD’s cannot be calibrated to the target power
 Ex81d  Some LD’s cannot be calibrated to target power
 Ex81e  The temperature of the environment is greater than 28degrees
 Ex81f  The temperature of the environment is less than 18degrees
 Ex820  Sensor for the temperature of the environment has not been connected
 Ex821  Trail clamps are nearing the end of its usable life
 Ex822  Trail clamps have been used for more than the endurance time
 Ex823  Backup/restore of the data on NVRAM can’t be performed, because the Dip-Sw 2 is not on
 Ex824  The backup of the data on NVRAM is not in Flash-Memory
 Ex825  Calibration must be done because there is some LD which doesn’t reach the target power. But, LD calibration can not processed because temperature of LD block is too low
 Ex826  The direction where a connected conveyer can’t be changed is set up in the plate types setting
 Ex827  No response was returned from the conveyor
 Ex828  An error was returned from the conveyer toward the switching command
 Ex829  The conveyer can’t be changed to the direction that is set up in the plate types setting
 Ex82a  Since the light intensity of laser diodes is detected as having deviated more than +-5% from the specified value, the equipment executes the calibration
 Ex82b  The head task was hanged up.
 Ex82c  Head:Iopd data error
 Ex850  Communication with the RAS server was interrupted. (RAS server was turned off or RS-232C cable was drawn out)
 Ex851  No response come from DNS
 Ex852  Communication with the RAS server has resume
 Ex853  It failed in the connection to the rotating light server
 Ex854  The name of the mail server isn’t right
 Ex855  It failed in the connection to the mail server
 Ex856  Mail account was rejected
 Ex857  An error occurred in the transmission of DATA command
 Ex858  An error occurred in the transmission of header
 Ex859  An error occurred in the transmission of body
 Ex85a  An error occurred in the transmission of attached file
 Ex85b  An error occurred in the transmission of TO command
 Ex85c  A command was sent to the SMTP server. But, no answer was returned from the server
 Ex880  Servo pack: Time-out error occurred while receiving data
 Ex881  Servo-Pack:Address error
 Ex882  Servo-Pack:Data error
 Ex883  Servo-Pack:Check sum error
 Ex884  Servo-Pack:Undefined error code
 Ex885  Servo-Pack:Number of received characters are insufficient
 Exd01  Excessive current in the LD drive (driver 1 board)
 Exd02  Excessive current in the LD drive (driver 2 board)
 Exd03  Excessive current in the LD drive (driver 3 board)
 Exd04  Excessive current in the LD drive (driver 4 board)
 Exd05  Driver board temperature error
 Exd08  Irregular peltier
 Exd09  Irregular FES board power supply
 Exd0a  Irregular +9 V power supply
 Exd21  Temperature at the RH base > 35degrees (Temperature of environment > 28degrees)
 Exd22  Temperature at the periphery of the optical unit is high
 Exd25  Sensor for the RH base has not been connected
 Exd28  Temperature of the LD block is low
 Exd30  Writing error occurred when the recording head received the AC command
 Exd31  Writing error on EEPROM
 Exd32  Data error due to a divide-by-zero error
 Exd33  Calibration must be done
 Exd40  Temperature of the LD block is high. block 0
 Exd41  Temperature of the LD block is high. block 1
 Exd42  Temperature of the LD block is high. block 2
 Exd43  Temperature of the LD block is high. block 3
 Exd44  Temperature of the LD block is high. block 4
 Exd45  Temperature of the LD block is high. block 5
 Exd46  Temperature of the LD block is high. block 6
 Exd47  Temperature of the LD block is high. block 7
 Exd48  Temperature of the LD block > 28degrees
(Temperature at the periphery of the optical unit > 35degrees. Temperature of environment ≤ 28degrees.) block 0
 Exd49  Temperature of the LD block > 28degrees
(Temperature at the periphery of the optical unit > 35degrees. Temperature of environment ≤ 28degrees.) block 1
 Exd4a  Temperature of the LD block > 28degrees
(Temperature at the periphery of the optical unit > 35degrees. Temperature of environment ≤ 28degrees.) block 2
 Exd4b  Temperature of the LD block > 28degrees
(Temperature at the periphery of the optical unit > 35degrees. Temperature of environment ≤ 28degrees.) block 3
 Exd4c  Temperature of the LD block > 28degrees
(Temperature at the periphery of the optical unit > 35degrees. Temperature ofenvironment ≤ 28degrees.) block 4
 Exd4d  Temperature of the LD block > 28degrees
(Temperature at the periphery of the optical unit > 35degrees. Temperature of environment ≤ 28degrees.) block 5
 Exd4e  Temperature of the LD block > 28degrees
(Temperature at the periphery of the optical unit > 35degrees. Temperature of environment ≤ 28degrees.) block 6
 Exd4f  Temperature of the LD block > 28degrees
(Temperature at the periphery of the optical unit > 35degrees. Temperature of environment ≤ 28degrees.) block 7
 Exd50  Temperature of the LD block > 28degrees
(Temperature at the periphery of the optical unit ≤ 35degrees. Temperature of environment > 28degrees.) block 0
 Exd51  Temperature of the LD block > 28degrees
(Temperature at the periphery of the optical unit ≤ 35degrees. Temperature of environment > 28degrees.) block 1
 Exd52  Temperature of the LD block > 28degrees
(Temperature at the periphery of the optical unit ≤ 35degrees. Temperature of environment > 28degrees.) block 2
 Exd53  Temperature of the LD block > 28degrees
(Temperature at the periphery of the optical unit ≤ 35degrees. Temperature of environment > 28degrees.) block 3
 Exd54  Temperature of the LD block > 28degrees
(Temperature at the periphery of the optical unit ≤ 35degrees. Temperature of environment > 28degrees.) block 4
 Exd55  Temperature of the LD block > 28degrees
(Temperature at the periphery of the optical unit ≤ 35degrees. Temperature of environment > 28degrees.) block 5
 Exd56  Temperature of the LD block > 28degrees
(Temperature at the periphery of the optical unit ≤ 35degrees. Temperature of environment > 28degrees.) block 6
 Exd57  Temperature of the LD block > 28degrees
(Temperature at the periphery of the optical unit ≤ 35degrees. Temperature of environment > 28degrees.) block 7
 Exd58  Temperature of the LD block > 28degrees
(Temperature at the periphery of the optical unit ≤ 35degrees. Temperature of environment ≤ 28degrees.) block 0
 Exd59  Temperature of the LD block > 28degrees
(Temperature at the periphery of the optical unit ≤ 35degrees. Temperature of environment ≤ 28degrees.) block 1
 Exd5a  Temperature of the LD block > 28degrees
(Temperature at the periphery of the optical unit ≤ 35degrees. Temperature of environment ≤ 28degrees.) block 2
 Exd5b  Temperature of the LD block > 28degrees
(Temperature at the periphery of the optical unit ≤ 35degrees. Temperature of environment ≤ 28degrees.) block 3
 Exd5c  Temperature of the LD block > 28degrees
(Temperature at the periphery of the optical unit ≤ 35degrees. Temperature of environment ≤ 28degrees.) block 4
 Exd5d  Temperature of the LD block > 28degrees
(Temperature at the periphery of the optical unit ≤ 35degrees. Temperature of environment ≤ 28degrees.) block 5
 Exd5e  Temperature of the LD block > 28degrees
(Temperature at the periphery of the optical unit ≤ 35degrees. Temperature of environment ≤ 28degrees.) block 6
 Exd5f  Temperature of the LD block > 28degrees
(Temperature at the periphery of the optical unit ≤ 35degrees. Temperature of environment ≤ 28degrees.) block 7
 Exd60  Temperature of the radiator > 55degrees
(Temperature at the periphery of the optical unit > 35degrees. Temperature of environment > 28degrees.) block 0
 Exd61  Temperature of the radiator > 55degrees
(Temperature at the periphery of the optical unit > 35degrees. Temperature of environment > 28degrees.) block 1
 Exd62  Temperature of the radiator > 55degrees
(Temperature at the periphery of the optical unit > 35degrees. Temperature of environment > 28degrees.) block 2
 Exd63  Temperature of the radiator > 55degrees
(Temperature at the periphery of the optical unit > 35degrees. Temperature of environment > 28degrees.) block 3
 Exd64  Temperature of the radiator > 55degrees
(Temperature at the periphery of the optical unit > 35degrees. Temperature of environment > 28degrees.) block 4
 Exd65  Temperature of the radiator > 55degrees
(Temperature at the periphery of the optical unit > 35degrees. Temperature of environment > 28degrees.) block 5
 Exd66  Temperature of the radiator > 55degrees
(Temperature at the periphery of the optical unit > 35degrees. Temperature of environment > 28degrees.) block 6
 Exd67  Temperature of the radiator > 55degrees
(Temperature at the periphery of the optical unit > 35degrees. Temperature of environment > 28degrees.) block 7
 Exd68  Temperature of the radiator > 55degrees
(Temperature at the periphery of the optical unit > 35degrees. Temperature of environment ≤ 28degrees.) block 0
 Exd69  Temperature of the radiator > 55degrees
(Temperature at the periphery of the optical unit > 35degrees. Temperature of environment ≤ 28degrees.) block 1
 Exd6a  Temperature of the radiator > 55degrees
(Temperature at the periphery of the optical unit > 35degrees. Temperature of environment ≤ 28degrees.) block 2
 Exd6b  Temperature of the radiator > 55degrees
(Temperature at the periphery of the optical unit > 35degrees. Temperature of environment ≤ 28degrees.) block 3
 Exd6c  Temperature of the radiator > 55degrees
(Temperature at the periphery of the optical unit > 35degrees. Temperature of environment ≤ 28degrees.) block 4
 Exd6d  Temperature of the radiator > 55degrees
(Temperature at the periphery of the optical unit > 35degrees. Temperature of environment ≤ 28degrees.) block 5
 Exd6e  Temperature of the radiator > 55degrees
(Temperature at the periphery of the optical unit > 35degrees. Temperature of environment ≤ 28degrees.) block 6
 Exd6f  Temperature of the radiator > 55degrees
(Temperature at the periphery of the optical unit > 35degrees. Temperature of environment ≤ 28degrees.) block 7
 Exd70  Temperature of the radiator > 55degrees
(Temperature at the periphery of the optical unit ≤ 35degrees.) block 0
 Exd71  Temperature of the radiator > 55degrees
(Temperature at the periphery of the optical unit ≤ 35degrees.) block 1
 Exd72  Temperature of the radiator > 55degrees
(Temperature at the periphery of the optical unit ≤ 35degrees.) block 2
 Exd73  Temperature of the radiator > 55degrees
(Temperature at the periphery of the optical unit ≤ 35degrees.) block 3
 Exd74  Temperature of the radiator > 55degrees
(Temperature at the periphery of the optical unit ≤ 35degrees.) block 4
 Exd75  Temperature of the radiator > 55degrees
(Temperature at the periphery of the optical unit ≤ 35degrees.) block 5
 Exd76  Temperature of the radiator > 55degrees
(Temperature at the periphery of the optical unit ≤ 35degrees.) block 6
 Exd77  Temperature of the radiator > 55degrees
(Temperature at the periphery of the optical unit ≤ 35degrees.) block 7
 Exd78  Dew condensation error. block 0
 Exd79  Dew condensation error. block 1
 Exd7a  Dew condensation error. block 2
 Exd7b  Dew condensation error. block 3
 Exd7c  Dew condensation error. block 4
 Exd7d  Dew condensation error. block 5
 Exd7e  Dew condensation error. block 6
 Exd7f  Dew condensation error. block 7
 Exd80  The LD block has dew
(Temperature of the LD block < 22degrees. Temperature inside the machine ≥ 18degrees.) block 0
 Exd81  The LD block has dew
(Temperature of the LD block < 22degrees. Temperature inside the machine ≥ 18degrees.) block 1
 Exd82  The LD block has dew
(Temperature of the LD block < 22degrees. Temperature inside the machine ≥ 18degrees.) block 2
 Exd83  The LD block has dew
(Temperature of the LD block < 22degrees. Temperature inside the machine ≥ 18degrees.) block 3
 Exd84  The LD block has dew
(Temperature of the LD block < 22degrees. Temperature inside the machine ≥ 18degrees.) block 4
 Exd85  The LD block has dew
(Temperature of the LD block < 22degrees. Temperature inside the machine ≥ 18degrees.) block 5
 Exd86  The LD block has dew
(Temperature of the LD block < 22degrees. Temperature inside the machine ≥ 18degrees.) block 6
 Exd87  The LD block has dew
(Temperature of the LD block < 22degrees. Temperature inside the machine ≥ 18degrees.) block 7
 Exd88  The LD block has dew
(Temperature of the LD block < 22degrees. Temperature inside the machine < 18degrees.) block 0
 Exd89  The LD block has dew
(Temperature of the LD block < 22degrees. Temperature inside the machine < 18degrees.) block 1
 Exd8a  The LD block has dew
(Temperature of the LD block < 22degrees. Temperature inside the machine < 18degrees.) block 2
 Exd8b  The LD block has dew
(Temperature of the LD block < 22degrees. Temperature inside the machine < 18degrees.) block 3
 Exd8c  The LD block has dew
(Temperature of the LD block < 22degrees. Temperature inside the machine < 18degrees.) block 4
 Exd8d  The LD block has dew
(Temperature of the LD block < 22degrees. Temperature inside the machine < 18degrees.) block 5
 Exd8e  The LD block has dew
(Temperature of the LD block < 22degrees. Temperature inside the machine < 18degrees.) block 6
 Exd8f  The LD block has dew
(Temperature of the LD block < 22degrees. Temperature inside the machine < 18degrees.) block 7
 Exd90  Temperature of the LD block < 5degrees
(Temperature at the periphery of the optical unit ≥ 17degrees.) block 0
 Exd91  Temperature of the LD block < 5degrees
(Temperature at the periphery of the optical unit ≥ 17degrees.) block 1
 Exd92  Temperature of the LD block < 5degrees
(Temperature at the periphery of the optical unit ≥ 17degrees.) block 2
 Exd93  Temperature of the LD block < 5degrees
(Temperature at the periphery of the optical unit ≥ 17degrees.) block 3
 Exd94  Temperature of the LD block < 5degrees
(Temperature at the periphery of the optical unit ≥ 17degrees.) block 4
 Exd95  Temperature of the LD block < 5degrees
(Temperature at the periphery of the optical unit ≥ 17degrees.) block 5
 Exd96  Temperature of the LD block < 5degrees
(Temperature at the periphery of the optical unit ≥ 17degrees.) block 6
 Exd97  Temperature of the LD block < 5degrees
(Temperature at the periphery of the optical unit ≥ 17degrees.) block 7
 Exd98  Temperature of the LD block < 5degrees
(Temperature at the periphery of the optical unit < 17degrees. Temperature of environment ≥ 18degrees.) block 0
 Exd99  Temperature of the LD block < 5degrees
(Temperature at the periphery of the optical unit < 17degrees. Temperature of environment ≥ 18degrees.) block 1
 Exd9a  Temperature of the LD block < 5degrees
(Temperature at the periphery of the optical unit < 17degrees. Temperature of environment ≥ 18degrees.) block 2
 Exd9b  Temperature of the LD block < 5degrees
(Temperature at the periphery of the optical unit < 17degrees. Temperature of environment ≥ 18degrees.) block 3
 Exd9c  Temperature of the LD block < 5degrees
(Temperature at the periphery of the optical unit < 17degrees. Temperature of environment ≥ 18degrees.) block 4
 Exd9d  Temperature of the LD block < 5degrees
(Temperature at the periphery of the optical unit < 17degrees. Temperature of environment ≥ 18degrees.) block 5
 Exd9e  Temperature of the LD block < 5degrees
(Temperature at the periphery of the optical unit < 17degrees. Temperature of environment ≥ 18degrees.) block 6
 Exd9f  Temperature of the LD block < 5degrees
(Temperature at the periphery of the optical unit < 17degrees. Temperature of environment ≥ 18degrees.) block 7
 Exda0  Temperature of the LD block < 5degrees
(Temperature at the periphery of the optical unit < 17degrees. Temperature of environment < 18degrees.) block 0
 Exda1  Temperature of the LD block < 5degrees
(Temperature at the periphery of the optical unit < 17degrees. Temperature of environment < 18degrees.) block 1
 Exda2  Temperature of the LD block < 5degrees
(Temperature at the periphery of the optical unit < 17degrees. Temperature of environment < 18degrees.) block 2
 Exda3  Temperature of the LD block < 5degrees
(Temperature at the periphery of the optical unit < 17degrees. Temperature of environment < 18degrees.) block 3
 Exda4  Temperature of the LD block < 5degrees
(Temperature at the periphery of the optical unit < 17degrees. Temperature of environment < 18degrees.) block 4
 Exda5  Temperature of the LD block < 5degrees
(Temperature at the periphery of the optical unit < 17degrees. Temperature of environment < 18degrees.) block 5
 Exda6  Temperature of the LD block < 5degrees
(Temperature at the periphery of the optical unit < 17degrees. Temperature of environment < 18degrees.) block 6
 Exda7  Temperature of the LD block < 5degrees
(Temperature at the periphery of the optical unit < 17degrees. Temperature of environment < 18degrees.) block 7
 Exdb0  LD block can not cool. block 0
 Exdb1  LD block can not cool. block 1
 Exdb2  LD block can not cool. block 2
 Exdb3  LD block can not cool. block 3
 Exdb4  LD block can not cool. block 4
 Exdb5  LD block can not cool. block 5
 Exdb6  LD block can not cool. block 6
 Exdb7  LD block can not cool. block 7
 Exdb8  LD block can not cool. block 0
 Exdb9  LD block can not cool. block 1
 Exdba  LD block can not cool. block 2
 Exdbb  LD block can not cool. block 3
 Exdbc  LD block can not cool. block 4
 Exdbd  LD block can not cool. block 5
 Exdbe  LD block can not cool. block 6
 Exdbf  LD block can not cool. block 7
 Exdc0  Irregular peltier. block 0
 Exdc1  Irregular peltier. block 1
 Exdc2  Irregular peltier. block 2
 Exdc3  Irregular peltier. block 3
 Exdc4  Irregular peltier. block 4
 Exdc5  Irregular peltier. block 5
 Exdc6  Irregular peltier. block 6
 Exdc7  Irregular peltier. block 7
 Exdd0  TP1-TP3 peltier line is incorrect
 Exdd1  TP1-TP5 peltier line is incorrect
 Exdd2  TP1-TP7 peltier line is incorrect
 Exdd3  TP3-TP5 peltier line is incorrect
 Exdd4  TP3-TP7 peltier line is incorrect
 Exdd5  TP5-TP7 peltier line is incorrect
 Exdd6  TP2-TP4 peltier line is incorrect
 Exdd7  TP2-TP6 peltier line is incorrect
 Exdd8  TP2-TP8 peltier line is incorrect
 Exdd9  TP4-TP6 peltier line is incorrect
 Exdda  TP4-TP8 peltier line is incorrect
 Exddb  TP6-TP8 peltier line is incorrect
 Exe01  Excessive current in the LD drive (driver 1 board)
 Exe02  Excessive current in the LD drive (driver 2 board)
 Exe03  Excessive current in the LD drive (driver 3 board)
 Exe04  Excessive current in the LD drive (driver 4 board)
 Exe05  Driver board temperature error or FPGA Version error
 Exe06  -5 V power supply error
 Exe07  Calibration sensor is not connected
 Exe08  Offset error in the calibration sensor
 Exe09  Irregular 5 V power supply
 Exe0a  Irregular +15 V power supply
 Exe0b  Irregular -15 V power supply
 Exe0c  Irregular 24 V power supply
 Exe0d  Cover switch is OFF
 Exe0e  BL command error (counter value is 0)
 Exe0f  Zoom sensor does not detect
 Exe10  Focus sensor does not detect
 Exe11  Time over for home return.(zoom or focus motor)
 Exe12  Power supply irregular while the motor is driving.(zoom or focus motor)
 Exe13  [8600 ]Pulse motor has traveled beyond the away limit. (zoom or focus motor)
 Exe13  [8000-2]Pulse motor has traveled beyond the limit. (zoom or focus motor)
 Exe14  [8600 ]Pulse motor has traveled beyond the home limit. (zoom or focus motor)
 Exe14  [8600-2]Irregular power supply(instantaneous loss)
 Exe20  Temperature of the LD block is high
 Exe21  Temperature at the periphery of the optical unit is high
 Exe22  Temperature of the radiating fin of the Peltier element is high
 Exe23  Dew condensation error
 Exe24  Sensor for LD block has not been connected
 Exe25  Sensor for the periphery of the optical unit has not been connected
 Exe26  Sensor for the radiating fin of the Peltier element has not been connected
 Exe27  Sensor for the dew condensation detection sensor has not been connected
 Exe28  Temperature of the LD block is low
 Exe30  Power supply error occurred when the recording head received the DW command
 Exe31  Command error occurred when the recording head received the DW command
 Exe32  Download error occurred when the recording head received the DP command
 Exe33  Download error occurred when the recording head received the DF command
 Exe34  Download address error occurred
 Exe35  Error occurred when the recording head received the BU command
 Exe36  Error occurred when the recording head received the BD command
 Exe40  Writing error occurred when the recording head received the AC command
 Exe41  Writing error on EEPROM
 Exe42  RAM error
 Exe43  ROM check sum error
 Exe44  FPGA error
 Exe45  Data error due to a divide-by-zero error
 Exe60  LD Current setting error
 Exe61  Temperature of the LD block > 28degrees
(Temperature at the periphery of the optical unit > 35degrees. Temperature environment ≤ 28degrees)
 Exe62  Temperature of the LD block > 28degrees
(Temperature at the periphery of the optical unit ≤ 35degrees. Temperature of environment > 28degrees)
 Exe63  Temperature of the LD block > 28degrees
(Temperature at the periphery of the optical unit ≤ 35degrees. Temperature of environment ≤ 28degrees)
 Exe64  Temperature at the periphery of the optical unit > 35degrees
(Temperature of environment ≤ 28degrees)
 Exe65  Temperature of the radiator > 55degrees
(Temperature at the periphery of the optical unit > 35degrees. Temperature of environment ≤ 28degrees)
 Exe66  Temperature of the radiator > 55degrees
(Temperature at the periphery of the optical unit ≤ 35degrees)
 Exe67  The LD block has dew
(Temperature of the LD block < 22degrees. Temperature inside the machine ≥ 18degrees)
 Exe68  The LD block has dew
(Temperature of the LD block < 22degrees. Temperature inside the machine < 18degrees)
 Exe69  Temperature of the LD block < 5degrees
(Temperature at the periphery of the optical unit ≥ 17degrees)
 Exe6a  Temperature of the LD block < 5degrees
(Temperature at the periphery of the optical unit < 17degrees. Temperature of environment ≥ 18degrees)
 Exe6b  Temperature of the LD block > 28degrees
(Temperature at the periphery of the optical unit > 35degrees. Temperature of environment ≤ 28degrees)
 Exe6c  Temperature of the LD block > 28degrees
(Temperature at the periphery of the optical unit ≤ 35degrees. Temperature of environment > 28degrees)
 Exe6d  Temperature of the LD block > 28degrees
(Temperature at the periphery of the optical unit ≤ 35degrees. Temperature of environment ≤ 28degrees)
 Exe6e  Temperature at the periphery of the optical unit > 35degrees
(Temperature of environment ≤ 28degrees)
 Exe6f  Temperature of the radiator > 55degrees
(Temperature at the periphery of the optical unit > 35degrees. Temperature of environment ≤ 28degrees)
 Exe70  Temperature of the radiator > 55degrees
(Temperature at the periphery of the optical unit ≤ 35degrees)
 Exe71  It is just before an exposure head has dew
(Temperature of the LD block < 22degrees. Temperature of environment ≥ 18 degrees)
 Exe72  It is just before an exposure head has dew
(Temperature of the LD block < 22degrees. Temperature of environment < 18 degrees)
 Exe73  5degrees ≤ Temperature of the LD block < 17degrees
(Temperature of environment ≥ 18degrees)
 Exe74  5degrees ≤ Temperature of the LD block < 17degrees
(Temperature of environment < 18degrees)
 Exea0  Light intensity adjustment error 0ch
 Exea1  Light intensity adjustment error 1ch
 Exea2  Light intensity adjustment error 2ch
 Exea3  Light intensity adjustment error 3ch
 Exea4  Light intensity adjustment error 4ch
 Exea5  Light intensity adjustment error 5ch
 Exea6  Light intensity adjustment error 6ch
 Exea7  Light intensity adjustment error 7ch
 Exea8  Light intensity adjustment error 8ch
 Exea9  Light intensity adjustment error 9ch
 Exeaa  Light intensity adjustment error 10ch
 Exeab  Light intensity adjustment error 11ch
 Exeac  Light intensity adjustment error 12ch
 Exead  Light intensity adjustment error 13ch
 Exeae  Light intensity adjustment error 14ch
 Exeaf  Light intensity adjustment error 15ch
 Exeb0  Light intensity adjustment error 16ch
 Exeb1  Light intensity adjustment error 17ch
 Exeb2  Light intensity adjustment error 18ch
 Exeb3  Light intensity adjustment error 19ch
 Exeb4  Light intensity adjustment error 20ch
 Exeb5  Light intensity adjustment error 21ch
 Exeb6  Light intensity adjustment error 22ch
 Exeb7  Light intensity adjustment error 23ch
 Exeb8  Light intensity adjustment error 24ch
 Exeb9  Light intensity adjustment error 25ch
 Exeba  Light intensity adjustment error 26ch
 Exebb  Light intensity adjustment error 27ch
 Exebc  Light intensity adjustment error 28ch
 Exebd  Light intensity adjustment error 29ch
 Exebe  Light intensity adjustment error 30ch
 Exebf  Light intensity adjustment error 31ch
 Exec0 Light intensity adjustment error 32ch
 Exec1  Light intensity adjustment error 33ch
 Exec2  Light intensity adjustment error 34ch
 Exec3  Light intensity adjustment error 35ch
 Exec4  Light intensity adjustment error 36ch
 Exec5  Light intensity adjustment error 37ch
 Exec6  Light intensity adjustment error 38ch
 Exec7  Light intensity adjustment error 39ch
 Exec8  Light intensity adjustment error 40ch
 Exec9  Light intensity adjustment error 41ch
 Execa  Light intensity adjustment error 42ch
 Execb  Light intensity adjustment error 43ch
 Execc  Light intensity adjustment error 44ch
 Execd  Light intensity adjustment error 45ch
 Exece  Light intensity adjustment error 46ch
 Execf  Light intensity adjustment error 47ch
 Exed0  Light intensity adjustment error 48ch
 Exed1  Light intensity adjustment error 49ch
 Exed2  Light intensity adjustment error 50ch
 Exed3  Light intensity adjustment error 51ch
 Exed4  Light intensity adjustment error 52ch
 Exed5  Light intensity adjustment error 53ch
 Exed6  Light intensity adjustment error 54ch
 Exed7  Light intensity adjustment error 55ch
 Exed8  Light intensity adjustment error 56ch
 Exed9  Light intensity adjustment error 57ch
 Exeda  Light intensity adjustment error 58ch
 Exedb  Light intensity adjustment error 59ch
 Exedc  Light intensity adjustment error 60ch
 Exedd  Light intensity adjustment error 61ch
 Exede  Light intensity adjustment error 62ch
 Exedf  Light intensity adjustment error 63ch
 Exee0  Incorrect command has been input
 Exee1  Temperature of the LD block > 28degrees
(Temperature at the periphery of the optical unit > 35degrees. Temperature of environment > 28degrees)
 Exee2  Temperature at the periphery of the optical unit > 35degrees
(Temperature of environment > 28degrees)
 Exee3  Temperature of the radiator > 55degrees
(Temperature at the periphery of the optical unit > 35degrees. Temperature of environment > 28degrees)
 Exee4  It is just before an exposure head has dew
(Temperature of the LD block ≥ 22degrees.)
 Exee5  Temperature of the LD block < 5degrees
(Temperature at the periphery of the optical unit < 17degrees. Temperature of environment < 18degrees.)
 Exef0  Recording head processing task is now processing another message
 Exef2  Recording head unit is not running
 Exef3  Check sum error occurred when data was uploaded
 Exef4  Address error occurred when data was uploaded
 Exef5  LD calibration can not processed because temperature of LD block is too low
 Exef6  A command was sent to the exposure head. But, no answer was returned from the exposure head
 Exfa0  System error (stack overflow)
 Exfa1  Floating point arithmetic error
 Exfa2  Divide-by-zero error
 Exfa3  System error (semaphore)
 Exfb0  Flash memory erase error
 Exfb1  Flash memory erase error (during verification)
 Exfb2  Flash memory write error
 Exfb3  Incompatible flash memory